TFS117 [VECTRON]

Filter specification; 过滤器规格
TFS117
型号: TFS117
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:123K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs117.doc  
Version 2.0  
21.03.2003  
VI TELEFILTER  
Filter specification  
TFS 117  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
288 || -22.2 pF  
258 || -22.6 pF  
Output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a  
of TFS117 is the minimum of the pass band attenuation a  
. This value is defined as the  
rel  
min  
insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level  
e
c
relative to the insertion loss a . The given values for the relative attenuation a and the group delay ripple have to be reached at the frequencies  
rel  
e
given below, even if the centre frequency f is shifted due to the temperature coefficient of frequency TC in the operating temperature range and  
c
f
due to a production tolerance for the centre frequency f .  
c
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
(reference level)  
a
f
5,0  
dB  
max.  
8
dB  
e
Nominal frequency  
Centre frequency  
-
117,4 MHz  
-
N
117,4  
MHz  
dB  
Pass band ripple  
within fN ± 90 kHz  
0,5  
max.  
1
dB  
Relative attenuation  
a
rel  
fN  
fN  
... fN  
±
90  
kHz  
kHz  
0,5  
0,5  
dB  
dB  
max.  
max.  
1
3
dB  
dB  
±
90  
1,8 MHz ... fN  
kHz ... fN ± 200  
fN  
fN  
fN  
fN  
±
±
+
-
±
±
6
30  
MHz  
MHz  
MHz  
MHz  
30  
42  
52  
52  
dB  
dB  
dB  
dB  
min. 20  
min. 35  
min. 20  
min. 20  
dB  
dB  
dB  
dB  
6
30  
30  
MHz ... fN  
MHz ... fN + 200  
MHz ... fN - 115  
Group delay  
Group delay ripple fN  
at fN  
±
800  
100  
ns  
ns  
max.  
max.  
1
1
µs  
µs  
90  
kHz  
Temperature coefficient of frequency (TC ) *)  
- 18  
ppm/K  
-
f
Operating temperature range  
Storage temperature range  
-
-
- 10 °C ... + 85 °C  
- 40 °C ... + 85 °C  
Input power level :  
max. 10  
dBm  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
**) f (Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz)  
c
generated:  
checked / approved:  
TELEFILTER GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No  
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)  
or information.  
Filename: tfs117.doc  
Version 2.0  
21.03.2003  
VI TELEFILTER  
Filter specification  
TFS 117  
2/5  
Construction and pin connection  
(All dimensions in mm)  
1
2
3
4
5
6
7
8
9
10  
Output  
Ground  
Ground  
Ground  
Ground  
Input  
Ground  
Ground  
Ground  
Ground  
TFS 117  
R12  
date code  
date code  
year + month  
N
P
R
...  
2001  
2002  
2003  
1
8
2
7
3
6
4
5
10  
9
50 matching network:  
L1  
L2  
1
6
Input  
Output  
50 Ohm  
SAW  
50 Ohm  
C1  
C2  
2,3,4,5,7  
8,9,10  
TELEFILTER GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No  
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)  
or information.  
Filename: tfs117.doc  
Version 2.0  
21.03.2003  
VI TELEFILTER  
Filter specification  
TFS 117  
3/5  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
plan, 3 plans;  
10 Hz to 500 Hz, 0,35 mm or <VIBRATIONACCEL> g respectively, 1 octave per min, 10 cycles per  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 – 3, with exeption of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters peer reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
2000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
Po  
2
P
Do  
W
: 16,00 ± 0,3  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
:
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
7,50 ± 0,1  
0,60  
2,00 ± 0,1  
12,00 ± 0,1  
1,50  
E
F
A
o
1
D
±
0,1  
13,4  
W
B
o
G
7,60 ± 0,1  
9,60 ± 0,1  
13,5 ± 0,1  
P1  
Ct  
COVER TAPE  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 16,4 +2/-0  
W2(max) : 22,4  
N(min)  
C
:
:
60  
12,8 ± 0,1  
C
A
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Marking of the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on the right.  
TELEFILTER GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No  
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)  
or information.  
Filename: tfs117.doc  
Version 2.0  
21.03.2003  
VI TELEFILTER  
Filter specification  
TFS 117  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
TELEFILTER GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No  
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)  
or information.  
Filename: tfs117.doc  
Version 2.0  
21.03.2003  
VI TELEFILTER  
Filter specification  
TFS 117  
5/5  
History  
Version  
Reason of Changes  
Name  
Date  
Filter specification  
2.0  
- terminating impedances amd typical values added  
Steiner  
21.03.2003  
TELEFILTER GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No  
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)  
or information.  

相关型号:

TFS1176

Filter specification
VECTRON

TFS117A

Filter Specification
VECTRON

TFS119

Filter Specification
VECTRON

TFS119A

SAW Filter Specification
VECTRON

TFS119B

Filter specification
VECTRON

TFS120

Filter Specification
VECTRON

TFS1200

Filter specification
VECTRON

TFS120A

Filter specification
VECTRON

TFS120C

Filter specification
VECTRON

TFS120E

Filter specification
VECTRON

TFS121

Filter Specification
VECTRON

TFS121B

Filter specification
VECTRON