TFS120 [VECTRON]

Filter Specification; 过滤器规格
TFS120
型号: TFS120
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器 LTE
文件: 总4页 (文件大小:46K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Tfs120.doc  
Version 1.2  
23.03.2000  
VI TELEFILTER  
Filter Specification  
TFS 120 - 1/4  
Measurement condition  
Ambient temperature TA:  
23 °C  
Input power level:  
0 dBm.  
Terminating impedances at f :  
for input:  
for output:  
30  
460 - 11,2 pF.  
440 - 13,0 pF.  
N
( typical value.)  
Q-value of matching elements:  
Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 120 is the minimum of the pass band attenuation a . The minimum of the pass band  
min  
e c  
rel  
attenuation a  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the  
min  
25 dB filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed on 120 MHz without tolerance. The given values for  
e
N
the relative attenuation a  
and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency f is  
c
rel  
shifted due to the temperature coefficient of frequency Tcf in the operating temperature range and due to a production tolerance for the centre  
frequency f .  
c
Data  
typ. value  
tolerance / limit  
Insertion loss (Reference level) :  
Nominal frequency :  
a
12,50  
dB  
max 15  
120  
dB  
e
f
MHz  
N
Centre frequency  
f
at ambient temperature ( fCAT  
)
120,01  
MHz  
c
Pass band :  
Bandwidth :  
f
– 100 kHz ..... f + 100 kHz  
N N  
1
dB - band width  
260  
764  
kHz  
MHz  
min. 200  
max. 800  
kHz  
kHz  
25 dB - band width  
Amplitude ripple in pass band (p-p):  
0,7  
dB  
max. 1,0  
dB  
Relative attenuation  
a
:
rel  
f
f
f
f
..... f ± 100  
kHz  
kHz  
kHz  
MHz  
-
-
-
-
max.  
1
dB  
dB  
dB  
dB  
N
N
N
N
N
± 400 kHz ...  
± 600 kHz ...  
f
f
f
± 600  
± 1000  
± 35  
min. 25  
min. 35  
min. 45  
N
N
N
± 1,0  
MHz ...  
Group delay (mean value in pass band) :  
Group delay ripple in pass band (p-p) :  
3,81  
100...150  
-
µs  
ns  
max. 4,0  
max. 200  
µs  
ns  
Deviation from linear phase in pass band :  
Triple transit attenuation compared to main signal  
Crosstalk attenuation compared to main signal  
40...50  
55...60  
dB  
dB  
Frequency inversion temperature ( To )  
30 °C  
ppm/ K²  
Temperature coefficient of frequency ( Tcf )  
-0,042  
Frequency deviation of f over temperature T : *):  
c
f (Hz) = Tcf x (T - To)² x fTo (MHz)  
c
Operating temperature range  
Storage temperature range  
- 20 °C ... + 75 °C  
- 40 °C ... + 85 °C  
Permissible DC voltage (V  
Permissible AC voltage (V  
)
-
-
12  
10  
V
V
DC  
pp  
)
* ) fTo is reference frequency f at frequency inversion temperature (To )  
c
Generated:  
Dunzow W.  
Dr. B.Wall.  
Checked / approved :  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs120.doc  
Version 1.2  
23.03.2000  
VI TELEFILTER  
Filter Specification  
TFS 120 - 2/4  
Package, pin grid 2,54 mm  
(All dimensions in mm)  
Pin 3 - Input.  
Pin 2 - Input RF Return.  
Pin 15 - Output.  
Pin 14 - Output RF Return.  
TFS  
tft  
120  
M12  
Pin 1,4,9,12,13,16,21,24 Package Ground.  
Pin 10, 11, 22, 23, Not connected.  
4,5  
50 - Matching network (see Application Note):  
L1  
1
2
3
4
9
12  
L3  
L2  
L4  
24  
21  
16 15 14 13  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Vectron International, Inc.  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs120.doc  
Version 1.2  
23.03.2000  
VI TELEFILTER  
Filter Specification  
TFS 120 - 3/4  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
Temperature: 150 °C - 170 °C  
Time: 60 sec. - 90 sec.  
main-heating periods  
over 200 °C  
20 sec. - 25 sec.  
peak temperature  
255 °C ± 5 °C  
Air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Vectron International, Inc.  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs120.doc  
Version 1.2  
23.03.2000  
VI TELEFILTER  
Filter Specification  
TFS 120 - 4/4  
History  
Version  
Reason of Changes  
Name  
Date  
1.0  
1.1  
.........  
Roßbach R.  
Weinberg R.  
03.09.1996.  
29.06.1999.  
Delete balanced matching network.  
1.2  
- add definition of centre frequency f  
;
Dunzow W.  
23.03.2000.  
c
- remove information about source and load impedances ;  
- remove information about termination impedances ;  
- add Bandwidth” , “Amplitude ripple” and  
Frequency deviation of f over temperature T ” to characteristics ;  
c
- mark L3 of matching network as adjustable;  
- change style of picture of matching network ;  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS1200

Filter specification
VECTRON

TFS120A

Filter specification
VECTRON

TFS120C

Filter specification
VECTRON

TFS120E

Filter specification
VECTRON

TFS121

Filter Specification
VECTRON

TFS121B

Filter specification
VECTRON

TFS1220

Filter specification
VECTRON

TFS1220B

VI TELEFILTER
VECTRON

TFS1220_03

The filter is single ended driven
VECTRON

TFS1237

Filter specification
VECTRON

TFS124

Filter Specification
VECTRON

TFS125A

Filter Specification
VECTRON