TFS182 [VECTRON]
Filter specification; 过滤器规格![TFS182](http://pdffile.icpdf.com/pdf1/p00166/img/icpdf/TFS18_930170_icpdf.jpg)
型号: | TFS182 |
厂家: | ![]() |
描述: | Filter specification |
文件: | 总5页 (文件大小:169K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Filename: tfs 182.doc
Version 1.2
11.11.2004
VI TELEFILTER
Filter specification
TFS 182
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
25
0±2
°C
dBm
50 Ω || 0 pF
50 Ω || 0 pF
Output:
Characteristics
Remark:
The reference level for the relative attenuation a
of the TFS 182 is the minimum of the pass band attenuation a
. The minimum of the pass band
min
rel
attenuation a
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 20 dB
e c
min
filter attenuation level relative to the insertion loss a . The frequency shift of the filter in the operating temperature range is not included in the production
e
tolerance scheme.
D a t a
typ. value
tolerance / limit
a
23,5
-
dB
max.
28,0
dB
Insertion loss
(reference level)
e
fN
-
182,5
MHz
Nominal frequency
Centre frequency
Pass band
fC
PB
p-p
p-p
182,5
-
MHz
-
fN
± 2
MHz
0,2
0,4
dB
dB
max.
max.
0,6
1
dB
dB
Pass band ripple
Amplitude ripple fN ±12,5MHz
Relative attenuation
a
rel
MHz
MHz
fN
fN
... fN
±
±
2
12,5
0,2
0,4
dB
dB
max.
max.
0,6
1
dB
dB
±
2
MHz ... fN
fN
fN
fN
fN
-
-
+
+
82,50 MHz ... fN
45,00 MHz ... fN
32,50 MHz ... fN
45,00 MHz ... fN
-
-
+
+
45,00 MHz
32,50 MHz
45,00 MHz
82,50 MHz
55
55
55
55
dB
dB
dB
dB
min.
min.
min.
min.
45
40
30
35
dB
dB
dB
dB
305
5
ns
ns
max.
max.
max.
350
10
ns
Absolute group delay
Group delay ripple within PB
Input power level
p-p
ns
+10
dBm
OTR
-
-
-40 °C ... + 85 °C
Operating temperature range
Storage temperature range
-40 °C ... + 85 °C
-
TC
f
*
-80
ppm/K
Temperature coefficient of frequency
*) ∆f (Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
c
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 182.doc
Version 1.2
11.11.2004
VI TELEFILTER
Filter specification
TFS 182
2/5
Filter characteristic
0.381
0.372
0.363
0.354
0.345
0.336
0.327
0.318
0.309
0.3
0
0
-1
-8
-16
-24
-32
-40
-48
-56
-64
-72
-80
-2
-3
-4
-5
-6
-7
-8
-9
0.291
-10
123.6 135.4 147.2 159 170.8 182.6 194.4 206.2 218 229.8 241.6
frequency in MHz
161.6 165.8 170 174.2 178.4 182.6 186.8 191 195.2 199.4 203.6
frequency in MHz
Construction and pin connection
(All dimensions in mm)
13,6Max.
1
2
3
4
Ground
Ground
Ground
Ground
5
Output
6
7
Output RF Return
Ground
TFS 182
8
9
10
11
12
Ground
Ground
Ground
Input
●
1
S46
Date code
Input RF Return
2,54 ±0,15
1,5
Date code: Year + week
2
1
3 4
S
T
2004
2005
2006
12
11
5
6
U
...
9 8
10
7
0,1
0,8
50 Ohm Test circuit
11
12
5
6
L2
L1
SAW
1, 2, 3, 4, 7, 8, 9, 10
Stability characteristics
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 182.doc
Version 1.2
11.11.2004
VI TELEFILTER
Filter specification
TFS 182
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
P2
Tape (all dimensions in mm)
Date Code
W
: 24,00 +0,30/-0,10
Po
t
Do
Po
Do
E
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
P2
:
:
0,60
2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
Ao
:
:
1,50
7,10 ± 0,10
Ko
Typ
PIN Marker
D1
Ao
Bo
Ct
: 13,90 ± 0,10
: 21,5 ± 0,1
W
2
Reel (all dimensions in mm)
A
:330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
C
: 60
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 182.doc
Version 1.2
11.11.2004
VI TELEFILTER
Filter specification
TFS 182
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 182.doc
Version 1.2
11.11.2004
VI TELEFILTER
Filter specification
TFS 182
5/5
History
Version
Reason of Changes
Name
Date
1.0
1.1
- generated specification according to customer requirement
- change group delay ripple from max. 5ns to max. 10ns
- add absolute group delay max. 350ns
Strehl
Strehl
24.08.2004
21.09.2004
- add temperature coefficient of frequency
1.2
- terminating impedance fixed
Pfeiffer
11.11.2004
- typical values and filter characteristic added
- air reflow temperature conditions modified
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明