M-FIAM5  
Military 28Vin Filter  
Input Attenuator Module  
45  
Features  
EMI filtering-MIL-STD-461E  
Transient protection-MIL-STD-704E1  
Environments-MIL-STD-810, MIL-STD-202  
Environmental stress screening  
Low profile mounting options  
Output current up to 20 Amps  
Mini sized package  
Shown actual size:  
2.28 x 2.2 x 0.5 in  
57,9 x 55,9 x 12,7 mm  
Inrush current limiting  
Reverse polarity protection  
Product Highlights  
Absolute Maximum Rating  
The M-FIAM5 is a DC front-end module  
that provides EMI filtering and transient  
protection required in military applications.  
The M-FIAM5 enables designers using  
Vicor 2nd Generation 24V DC-DC converters  
to meet conducted emission/conducted  
susceptibility per MIL-STD-461E; and  
input transients per MIL-STD-704E1. The  
M-FIAM5 accepts an input voltage of  
18-36Vdc and delivers output current  
up to 20 Amps.  
Parameter  
+In to –In  
+In to –In  
Mounting torque  
Pin Soldering temperature  
Pin Soldering temperature  
Operating temperature HGrade  
Storage temperature HGrade  
Operating temperature MGrade  
Storage temperature MGrade  
Rating  
36  
50  
5(0.57)  
500 (260)  
750 (390)  
-40 to +100  
-55 to +125  
-55 to +100  
-65 to +125  
Unit  
Vdc  
Vdc  
in-lbs  
°F(°C)  
°F(°C)  
°C  
°C  
°C  
°C  
Notes  
Continuous  
100ms  
6 each, #4-40 or M3  
<5 sec; wave solder  
<7 sec; hand solder  
Baseplate  
Baseplate  
M-FIAM5 is housed in an industry  
Specifications  
standard "half brick" module measuring  
2.28" x 2.2" x 0.5" and depending upon  
model selected, may be mounted on-board  
or in-board for height critical applications.  
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)  
Parameter  
Input voltage  
Min  
Typ  
Max  
36Vdc  
Remarks  
18Vdc  
28Vdc  
Continuous  
Output current  
20A  
Inrush limiting  
0.007A/µF  
Compatible Products  
• 2nd Generation 24V Input  
DC-DC converters  
Transient immunity  
EMI:MIL-STD-461E  
Conducted emissions:  
MIL-STD-704E  
CE101, CE102  
See footnote 1  
Conducted susceptibility: CS101, CS114, CS115, CS116  
Dielectric withstand  
1,500Vrms  
2,121Vdc  
98%  
Input/Output to Base  
Input/Output to Base  
Part Number Format  
M-FIAM5 M 2 1  
Efficiency  
96%  
Internal voltage drop  
ON/OFF control  
Enable (ON)  
Disable (OFF)  
External capacitance  
0.5  
1.0  
@20A, 100°C baseplate  
Product  
0.0Vdc  
3.5Vdc  
1.0Vdc  
5.0Vdc  
Referenced to –Vout.  
100kinternal pull-up resistor  
See illustration C1 on page 3.  
50V  
Ounces (grams)  
Years  
Pin Style  
Product Grade(°C)  
H = –40 to +100  
M = –55 to +100  
1 = Short  
2 = Long  
*S=Short ModuMate  
*N=Long ModuMate  
Baseplate  
1 = Slotted  
2 = Threaded  
3 = Thru-hole  
330µF  
1000µF  
4 (113)  
2
Weight  
Warranty  
3.1 (88)  
*Compatible with SurfMate and InMate socketing system.  
1 MIL-STD-704E Compliance requires an external circuit. See addendum A  
MTBF per MIL-HDBK-217F  
Thermal Resistance  
Temp  
25°C  
50°C  
65°C  
Environment  
MTBF  
3,334,295  
786,893  
650,187  
Unit  
Hrs  
Hrs  
Hrs  
Parameter  
Baseplate to sink; flat, greased surface  
Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt  
Baseplate to ambient  
Typ  
0.16°C/Watt  
Ground Benign:G.B.  
Naval Sheltered:N.S.  
Airborne Inhabited Cargo:A.I.C.  
7.9°C/Watt  
2.2°C/Watt  
Baseplate to sink; 1000 LFM  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MFIAM5  
Rev. 1.7  
Page 1 of 5  
Set your site on VICOR at www.vicorpower.com  
Environmental Qualification  
Environmental Stress Screening  
H Grade  
M Grade  
Altitude  
Operating Temp.  
Storage Temp.  
-40°C to +100°C  
-55°C to +125°C  
12 cycles  
-55°C to +100°C  
-65°C to +125°C  
12 cycles  
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and  
70,000 ft. Operational.  
Temp. Cycling:*  
-65°C to +100°C  
-65°C to +100°C  
Explosive Atmosphere  
MIL-STD-810F, Method 511.4, Procedure I, Operational.  
Ambient Test  
@ 25°C  
Yes  
Yes  
Power Cycling  
Burn-In:  
12 hours,  
28 cycles  
24 hours,  
56 cycles  
Vibration  
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine  
and Random vibration per Table 514.5C for Helicopter AH-6J  
Main Rotor with overall level of 5.6 grams for 4 hours per axis.  
MIL-STD-810F, Method 514.5C, General Minimum Integrity  
Curve per Figure 514.5C-17 with overall level of 7.7 grams  
for 1 hour per axis.  
Functional and  
Parametric  
ATE Tests:  
Hi-Pot Test  
Visual Inspection:  
Test Data  
-40°C and  
+100°C  
-55°C and  
+100°C  
Yes  
Yes  
Yes  
Yes  
vicorpower.com  
vicorpower.com  
Shock  
*Temperature cycled with power off, 17°C per minute rate of change.  
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's.  
MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.  
MIL-STD-202F, Method 213B, 60 G's, 9ms half sine.  
MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.  
Conducted Noise  
Acceleration  
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II,  
Operational, 2-7 G's, 6 directions.  
Humidity  
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.  
Solder Test  
MIL-STD-202F, Method 208, 8 hour aging.  
Figure 1– M-FIAM5 and Model V24A12M400A  
DC-DC converter operating at 28Vdc, 400W.  
Inrush Limiting  
Transient Immunity  
Figure 3– Inrush Limiting: Inrush current with 1000µF  
Figure 2 – Transient Immunity: M-FIAM5 output response to  
external capacitance.  
an input transient.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MFIAM5  
Rev. 1.7  
Page 2 of 5  
Set your site on VICOR at www.vicorpower.com  
Transient and Surge Protection  
Note: The M-FIAM5 is shown in the on state. To disable,  
open the connection between ON/OFF and –Out.  
Capacitance (C1)  
330µF(min),1000µF(max)  
Recommended Fuse:  
20A Max., F03A Type  
–IN  
–OUT  
–S  
–IN  
PR  
ON  
OFF  
EMI  
GND  
2nd Generation  
24Vdc Input  
DC-DC Converters  
MOV P/N  
20461-068  
C1  
SC  
M-FIAM5NC  
PC  
NC  
NC  
+S  
+
+
+IN  
+OUT  
+IN  
Mechanical Diagram  
Module Pins  
0.50 ±0.02  
12,7 ±0,5  
No.  
Function  
Label  
1
+In  
+
No  
Connection  
2
NC  
2.20  
0.01  
55,9  
1.74  
44,2  
3
4
5
6
Ground  
In  
EMI/GND  
0.23  
5,8  
(REF)  
2.000  
50,80  
0.10  
2,5  
style 2 & 3  
baseplates only  
(4X)***  
0.49  
12,4  
0.12* 0.20**  
3,1 5,1  
0.300 ±0.015  
7,62 ±0,38  
Out  
0.10  
X 45˚  
2,5  
CHAMFER  
ON/OFF  
ON/OFF  
No  
Connection  
1
9
2
8
3
6
4
5
0.35  
(2X)  
0.300 ±0.015  
7,62 ±0,38  
7
NC  
0.65  
16,5  
FULL R (6X)  
8,8  
2.28  
1.30  
57,9  
1.900  
48,26  
ALUMINUM  
No  
Connection  
33,0  
8
9
NC  
+
BASEPLATE  
0.130  
(6X)  
3,30  
7
+Out  
Use a 4-40 Screw (6X)  
Torque to:  
0.150  
DIA,(2X)  
0.43  
10,9  
0.06  
1,5  
3,81  
0.080  
2,03  
5 in-lbs  
.57 N-m  
R
(3X)  
2.20  
55,9  
(REF.)  
0.400  
10,16  
DIA,(7X)  
0.54  
(9X)  
13,7  
0.700  
17,78  
Pin Style 1&S  
(Short Pin)  
1.000  
25,40  
1.400  
35,56  
0.62  
(9X)  
15,7  
Slotted (Style 1)  
or  
Pin Style 2&N  
(Long Pin)  
Threaded (Style 2)  
4-40 UNC-2B (6X)  
or  
Thru Hole (Style 3)  
#30 Drill Thru (6X)  
(0.1285)  
*
Style 1 baseplate only  
** Style 2 & 3 baseplates  
*** Reserved for Vicor accessories  
Not for mounting  
PCB Mounting Specifications  
INBOARD  
SOLDER  
MOUNT  
ONBOARD  
SOLDER  
MOUNT  
ALL MARKINGS  
THIS SURFACE  
PIN STYLE 1&S  
PIN STYLE 2&N  
0.062 ±0.010  
PCB THICKNESS  
0.094 ±0.003  
2,39 ±0,08  
0.094 ±0.003  
2,39 ±0,08  
(7X)  
(2X)  
1,57 ±0,25  
PLATED  
THRU HOLE  
DIA  
0.164 ±0.003  
4,16 ±0,08  
0.164 ±0.003  
4,16 ±0,08  
1.790  
45,47  
0.06  
R
(4X)  
0.158  
4,01  
1,5  
ALUMINUM  
BASEPLATE  
1
2
3
4
PINS STYLES  
1.584*  
40,23  
STYLE 1 & 2: TIN/LEAD  
HOT SOLDER DIPPED  
1.900*  
48.,26  
STYLE S & N: GOLD PLATED COPPER  
9
8
7
6
5
0.400*  
0.43  
10,9  
0.53  
13,5  
10,16  
0.700*  
17,78  
1.000*  
25,40  
* DENOTES  
±0.003  
0.195  
4,95  
1.400*  
35,56  
TOL =  
±0,08  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MFIAM5  
Rev. 1.7  
Page 3 of 5  
Set your site on VICOR at www.vicorpower.com  
Addendum A  
MIL-STD-704E Transient / Overvoltage Protection  
The standard (COTS) 24V input 2nd Generation Converter Modules may be used in Military 28 volt applications. The  
M-FIAM5 provides compliance to MIL-STD-461E conducted emissions and susceptibility standards. Additional circuitry,  
as illustrated in the accompanying schematic (see Fig. 1), provides compliance to the MIL-STD-704E transient  
overvoltage specification. The 24V input modules employ undervoltage and overvoltage protection. These converters,  
shut down if the input falls below 18V or rises to 36V or above.18V is consistent with the MIL-STD-704E specification,  
but the standard also requires uninterrupted performance in the event of an input voltage transient to 50V for a period  
of 12.5 millisec. The above referenced circuit clamps the input voltage, in the event that it exceeds 32V, as illustrated in  
figure 2. This performance prevents the converter from shutting down, thus meeting the transient overvoltage  
specification of MIL- STD-704E.  
+28V  
Transient Surpressor Circuit  
Vicor FIAM & Mods  
Vc  
C1  
C2  
C3  
D1  
Q1  
R1  
R2  
R3  
R4  
R5  
R6  
R7  
R8  
R9  
R10  
U1  
U2  
4.7uF, 63V  
0.1uF  
880uF, 100V  
1N5245B  
IRFP3710ND  
2.0K  
2.0K  
64.5K  
64.5K  
10K  
R1  
R2  
2.0k  
2.0k  
Vout  
C3  
Cbulk  
880 Uf d  
10K  
1K  
24.3K  
14K  
Input  
R8  
2
U1B  
LM258N  
R4  
R3  
8
4
U1A  
LM258N  
615001  
24.3k  
64.9k  
R10  
64.9k  
Q1  
IRFP3710  
ND PN  
5
6
+
8
1.0K  
R7  
1.0k  
1K  
3
1
7
+
LM258N  
LM4040CIZ-5.0  
1
2
C1  
4.7uf, 63v  
3
R9  
4
14.0k  
R5  
4
D1  
10K  
15v, 1N5245B  
R6  
2
10K  
3
C2  
.1ufd  
U2  
LM4040CIZ-5.0  
+28v  
rtn  
Figure 1– Transient / Overvoltage protection circuit.  
Volts  
50  
32  
Vin  
Vout  
28  
27  
12.5 Millisec Max  
Figure 2– Overvoltage clamping  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MFIAM5  
Rev. 1.7  
Page 4 of 5  
Set your site on VICOR at www.vicorpower.com  
Vicor’s comprehensive line of power solutions includes modular, high  
density DC-DC converters and accessory components, configurable power  
supplies, and custom power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is  
assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent  
rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems,  
wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and  
Conditions of Sale, which are available upon request.  
Specifications are subject to change without notice.  
Component Solutions  
for Your Power System  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
978-470-2900  
Fax: 978-475-6715  
Email  
Vicor Express: vicorexp@vicr.com  
Technical Support: apps@vicr.com  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
MFIAM5  
Rev. 1.7  
04/03/10M  

相关型号:

M-FIAM5BH11

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BH12

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BH13

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BH21

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BH22

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BH23

Military COTS28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHF1

Military COTS 28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHF2

Military COTS 28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHF3

Military COTS 28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHG1

Military COTS 28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHG2

Military COTS 28 Vin Filter Input Attenuator Module
VICOR

M-FIAM5BHG3

Military COTS 28 Vin Filter Input Attenuator Module
VICOR