M-FIAM5 [VICOR]
Military 28Vin Filter Input Attenuator Module; 军事28Vin滤波器输入衰减模块型号: | M-FIAM5 |
厂家: | VICOR CORPORATION |
描述: | Military 28Vin Filter Input Attenuator Module |
文件: | 总5页 (文件大小:189K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
M-FIAM5
Military 28Vin Filter
Input Attenuator Module
45
Features
• EMI filtering-MIL-STD-461E
• Transient protection-MIL-STD-704E1
• Environments-MIL-STD-810, MIL-STD-202
• Environmental stress screening
• Low profile mounting options
• Output current up to 20 Amps
• Mini sized package
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
• Inrush current limiting
• Reverse polarity protection
Product Highlights
Absolute Maximum Rating
The M-FIAM5 is a DC front-end module
that provides EMI filtering and transient
protection required in military applications.
The M-FIAM5 enables designers using
Vicor 2nd Generation 24V DC-DC converters
to meet conducted emission/conducted
susceptibility per MIL-STD-461E; and
input transients per MIL-STD-704E1. The
M-FIAM5 accepts an input voltage of
18-36Vdc and delivers output current
up to 20 Amps.
Parameter
+In to –In
+In to –In
Mounting torque
Pin Soldering temperature
Pin Soldering temperature
Operating temperature H–Grade
Storage temperature H–Grade
Operating temperature M–Grade
Storage temperature M–Grade
Rating
36
50
5(0.57)
500 (260)
750 (390)
-40 to +100
-55 to +125
-55 to +100
-65 to +125
Unit
Vdc
Vdc
in-lbs
°F(°C)
°F(°C)
°C
°C
°C
°C
Notes
Continuous
100ms
6 each, #4-40 or M3
<5 sec; wave solder
<7 sec; hand solder
Baseplate
Baseplate
M-FIAM5 is housed in an industry
Specifications
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted on-board
or in-board for height critical applications.
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)
Parameter
Input voltage
Min
Typ
Max
36Vdc
Remarks
18Vdc
28Vdc
Continuous
Output current
20A
Inrush limiting
0.007A/µF
Compatible Products
• 2nd Generation 24V Input
DC-DC converters
Transient immunity
EMI:MIL-STD-461E
Conducted emissions:
MIL-STD-704E
CE101, CE102
See footnote 1
Conducted susceptibility: CS101, CS114, CS115, CS116
Dielectric withstand
1,500Vrms
2,121Vdc
98%
Input/Output to Base
Input/Output to Base
Part Number Format
M-FIAM5 M 2 1
Efficiency
96%
Internal voltage drop
ON/OFF control
Enable (ON)
Disable (OFF)
External capacitance
0.5
1.0
@20A, 100°C baseplate
Product
0.0Vdc
3.5Vdc
1.0Vdc
5.0Vdc
Referenced to –Vout.
100kΩ internal pull-up resistor
See illustration C1 on page 3.
50V
Ounces (grams)
Years
Pin Style
Product Grade(°C)
H = –40 to +100
M = –55 to +100
1 = Short
2 = Long
*S=Short ModuMate
*N=Long ModuMate
Baseplate
1 = Slotted
2 = Threaded
3 = Thru-hole
330µF
1000µF
4 (113)
2
Weight
Warranty
3.1 (88)
*Compatible with SurfMate and InMate socketing system.
1 MIL-STD-704E Compliance requires an external circuit. See addendum A
MTBF per MIL-HDBK-217F
Thermal Resistance
Temp
25°C
50°C
65°C
Environment
MTBF
3,334,295
786,893
650,187
Unit
Hrs
Hrs
Hrs
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt
Baseplate to ambient
Typ
0.16°C/Watt
Ground Benign:G.B.
Naval Sheltered:N.S.
Airborne Inhabited Cargo:A.I.C.
7.9°C/Watt
2.2°C/Watt
Baseplate to sink; 1000 LFM
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM5
Rev. 1.7
Page 1 of 5
Set your site on VICOR at www.vicorpower.com
Environmental Qualification
Environmental Stress Screening
H Grade
M Grade
Altitude
Operating Temp.
Storage Temp.
-40°C to +100°C
-55°C to +125°C
12 cycles
-55°C to +100°C
-65°C to +125°C
12 cycles
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and
70,000 ft. Operational.
Temp. Cycling:*
-65°C to +100°C
-65°C to +100°C
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Ambient Test
@ 25°C
Yes
Yes
Power Cycling
Burn-In:
12 hours,
28 cycles
24 hours,
56 cycles
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine
and Random vibration per Table 514.5C for Helicopter AH-6J
Main Rotor with overall level of 5.6 grams for 4 hours per axis.
MIL-STD-810F, Method 514.5C, General Minimum Integrity
Curve per Figure 514.5C-17 with overall level of 7.7 grams
for 1 hour per axis.
Functional and
Parametric
ATE Tests:
Hi-Pot Test
Visual Inspection:
Test Data
-40°C and
+100°C
-55°C and
+100°C
Yes
Yes
Yes
Yes
vicorpower.com
vicorpower.com
Shock
*Temperature cycled with power off, 17°C per minute rate of change.
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's.
MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 G's, 9ms half sine.
MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.
Conducted Noise
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II,
Operational, 2-7 G's, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
Figure 1– M-FIAM5 and Model V24A12M400A
DC-DC converter operating at 28Vdc, 400W.
Inrush Limiting
Transient Immunity
Figure 3– Inrush Limiting: Inrush current with 1000µF
Figure 2 – Transient Immunity: M-FIAM5 output response to
external capacitance.
an input transient.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM5
Rev. 1.7
Page 2 of 5
Set your site on VICOR at www.vicorpower.com
Transient and Surge Protection
Note: The M-FIAM5 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
Capacitance (C1)
330µF(min),1000µF(max)
Recommended Fuse:
20A Max., F03A Type
–IN
–
–
–OUT
–S
–IN
PR
ON
OFF
EMI
GND
2nd Generation
24Vdc Input
DC-DC Converters
MOV P/N
20461-068
C1
SC
M-FIAM5NC
PC
NC
NC
+S
+
+
+IN
+OUT
+IN
Mechanical Diagram
Module Pins
0.50 ±0.02
12,7 ±0,5
No.
Function
Label
1
+In
+
No
Connection
2
NC
2.20
0.01
55,9
1.74
44,2
3
4
5
6
Ground
–In
EMI/GND
0.23
5,8
(REF)
2.000
50,80
0.10
2,5
–
–
style 2 & 3
baseplates only
(4X)***
0.49
12,4
0.12* 0.20**
3,1 5,1
0.300 ±0.015
7,62 ±0,38
–Out
0.10
X 45˚
2,5
CHAMFER
ON/OFF
ON/OFF
No
Connection
1
9
2
8
3
6
4
5
0.35
(2X)
0.300 ±0.015
7,62 ±0,38
7
NC
0.65
16,5
FULL R (6X)
8,8
2.28
1.30
57,9
1.900
48,26
ALUMINUM
No
Connection
33,0
8
9
NC
+
BASEPLATE
0.130
(6X)
3,30
7
+Out
Use a 4-40 Screw (6X)
Torque to:
0.150
DIA,(2X)
0.43
10,9
0.06
1,5
3,81
0.080
2,03
5 in-lbs
.57 N-m
R
(3X)
2.20
55,9
(REF.)
0.400
10,16
DIA,(7X)
0.54
(9X)
13,7
0.700
17,78
Pin Style 1&S
(Short Pin)
1.000
25,40
1.400
35,56
0.62
(9X)
15,7
Slotted (Style 1)
or
Pin Style 2&N
(Long Pin)
Threaded (Style 2)
4-40 UNC-2B (6X)
or
Thru Hole (Style 3)
#30 Drill Thru (6X)
(0.1285)
*
Style 1 baseplate only
** Style 2 & 3 baseplates
*** Reserved for Vicor accessories
Not for mounting
PCB Mounting Specifications
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
ALL MARKINGS
THIS SURFACE
PIN STYLE 1&S
PIN STYLE 2&N
0.062 ±0.010
PCB THICKNESS
0.094 ±0.003
2,39 ±0,08
0.094 ±0.003
2,39 ±0,08
(7X)
(2X)
1,57 ±0,25
PLATED
THRU HOLE
DIA
0.164 ±0.003
4,16 ±0,08
0.164 ±0.003
4,16 ±0,08
1.790
45,47
0.06
R
(4X)
0.158
4,01
1,5
ALUMINUM
BASEPLATE
1
2
3
4
PINS STYLES
1.584*
40,23
STYLE 1 & 2: TIN/LEAD
HOT SOLDER DIPPED
1.900*
48.,26
STYLE S & N: GOLD PLATED COPPER
9
8
7
6
5
0.400*
0.43
10,9
0.53
13,5
10,16
0.700*
17,78
1.000*
25,40
* DENOTES
±0.003
0.195
4,95
1.400*
35,56
TOL =
±0,08
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM5
Rev. 1.7
Page 3 of 5
Set your site on VICOR at www.vicorpower.com
Addendum A
MIL-STD-704E Transient / Overvoltage Protection
The standard (COTS) 24V input 2nd Generation Converter Modules may be used in Military 28 volt applications. The
M-FIAM5 provides compliance to MIL-STD-461E conducted emissions and susceptibility standards. Additional circuitry,
as illustrated in the accompanying schematic (see Fig. 1), provides compliance to the MIL-STD-704E transient
overvoltage specification. The 24V input modules employ undervoltage and overvoltage protection. These converters,
shut down if the input falls below 18V or rises to 36V or above.18V is consistent with the MIL-STD-704E specification,
but the standard also requires uninterrupted performance in the event of an input voltage transient to 50V for a period
of 12.5 millisec. The above referenced circuit clamps the input voltage, in the event that it exceeds 32V, as illustrated in
figure 2. This performance prevents the converter from shutting down, thus meeting the transient overvoltage
specification of MIL- STD-704E.
+28V
Transient Surpressor Circuit
Vicor FIAM & Mods
Vc
C1
C2
C3
D1
Q1
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
U1
U2
4.7uF, 63V
0.1uF
880uF, 100V
1N5245B
IRFP3710ND
2.0K
2.0K
64.5K
64.5K
10K
R1
R2
2.0k
2.0k
Vout
C3
Cbulk
880 Uf d
10K
1K
24.3K
14K
Input
R8
2
U1B
LM258N
R4
R3
8
4
U1A
LM258N
615001
24.3k
64.9k
R10
64.9k
Q1
IRFP3710
ND PN
5
6
+
8
1.0K
R7
1.0k
1K
3
1
7
+
LM258N
LM4040CIZ-5.0
1
–
2
C1
4.7uf, 63v
3
–
R9
4
14.0k
R5
4
D1
10K
15v, 1N5245B
R6
2
10K
3
C2
.1ufd
U2
LM4040CIZ-5.0
+28v
rtn
Figure 1– Transient / Overvoltage protection circuit.
Volts
50
32
Vin
Vout
28
27
12.5 Millisec Max
Figure 2– Overvoltage clamping
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM5
Rev. 1.7
Page 4 of 5
Set your site on VICOR at www.vicorpower.com
Vicor’s comprehensive line of power solutions includes modular, high
density DC-DC converters and accessory components, configurable power
supplies, and custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is
assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent
rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems,
wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and
Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Component Solutions
for Your Power System
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
978-470-2900
Fax: 978-475-6715
Email
Vicor Express: vicorexp@vicr.com
Technical Support: apps@vicr.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM5
Rev. 1.7
04/03/10M