VEH40US12 [XPPOWER]
Energy Efficiency Level V;型号: | VEH40US12 |
厂家: | XP POWER LIMITED |
描述: | Energy Efficiency Level V |
文件: | 总2页 (文件大小:339K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
xppower.com
20/40 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC 2008 and EISA 2007 Compliant
Optional Inlet Connectors
Class II Versions
+60 °C Operating Temperature
Compact Dimensions
Low Cost
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 0.5 A max VEH20
1.0 A max VEH40
• 45 A/90 A for 115 VAC/230 VAC,
cold start at 25 °C
Efficiency
• 87% typical (average of measured values
with output loads of 25%, 50%, 75%
and 100%)
Energy Efficiency
Isolation
• Level V
• 3000 VAC Input to Output
1500 VAC Input to Ground*
500 VDC Output to Ground*
*Not C2 version
• VEH20: 63 kHz typical
VEH40: 20 kHz - 60 kHz variable
Inrush Current
Earth Leakage Current • 0.75 mA at 240 VAC/50 Hz
Power Factor
• EN61000-3-2, Class A
• Internal fuse fitted in line
VEH20: T1 A, 250 V
Switching Frequency
MTBF
Input Protection
• >250 kHrs to MIL-HDBK-217F at 25 °C,GB
VEH40: T3.15 A, 250 V
No Load Input Power • <0.3 W
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Storage Temperature • -40 °C to +85 °C
Output
Output Voltage
Minimum Load
Hold Up Time
• See table
• No minimum load required
• VEH20: 5 ms min, VEH40: 12 ms min,
at full load & 110 VAC
• 2 s max at full load 100 VAC
• 2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
• See table
Cooling
• Convection-cooled
• 5-95% RH, non-condensing
• 2000 m
Operating Humidity
Operating Altitude
Shock
Start Up Delay
• 10 g, 10 ms on 3 axes
Transient Response
EMC & Safety
Emissions
Regulation
• EN55022 level B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2 level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 level 2 Perf criteria A
Ripple & Noise
• 1% pk-pk max, 20 MHz bandwidth
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Overvoltage Protection • Not fitted
Overload Protection • 110-150%
Short Circuit Protection • Trip & restart (hiccup mode), auto recovery
Temperature
Coefficient
•
0.04%/°C
Surge
• EN61000-4-5 installation class 3
Perf criteria A
Conducted Immunity
Magnetic Field
• EN61000-4-6 level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• EN60950-1, UL/cUL60950-1,
Approved as Limited Power Source
VEH20/40
Models and Ratings
Max Output Power
Output Voltage(1)
Output Current
Total Regulation(2)
Model Number
15 W
20 W
20 W
20 W
20 W
20 W
25 W
40 W
40 W
40 W
40 W
40 W
5.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
5.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
3.00 A
1.67 A
1.33 A
1.11 A
0.83 A
0.42 A
5.00 A
3.33 A
2.67 A
2.22 A
1.67 A
0.83 A
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
VEH20US05(3,4)
VEH20US12(3,4)
VEH20US15(3,4)
VEH20US18(3,4)
VEH20US24(3,4)
VEH20US48(3,4)
VEH40US05
VEH40US12
VEH40US15
VEH40US18
VEH40US24
VEH40US48
Notes
1. Other output voltages available, contact sales for details
2. Total regulation includes line regulation and load regulation.
3. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add suffix ‘C6’ to model number, e.g. VEH20US12C6.
4. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number e.g. VEH20US12C2
Mechanical Details
VEH20
3.90 (99.0) For C8 and C6 inlet versions
4.11 (104.0) for C14 inlet versions
1.22 (31.0)
1.22 (31.0)
1.22 (31.0)
0.02
(0.5)
0.02
(0.5)
0.02
(0.5)
AC INPUT
IEC320-C8 INLET
(Optional C2 Version)
AC INPUT
IEC320-C6 INLET
(Optional C6 Version)
AC INPUT
IEC-320-C14 INLET
VEH40
1.19 (30.1)
4.21 (107.0)
0.02 (0.5)
AC INPUT
IEC320-C14 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance 0.04 ( 1.0) max.
2. Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40
3. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0).
4. Output cable length is 48” (1220mm) approx.
5. For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II