VEH40US12 [XPPOWER]

Energy Efficiency Level V;
VEH40US12
型号: VEH40US12
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

Energy Efficiency Level V

文件: 总2页 (文件大小:339K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
xppower.com  
20/40 Watts  
VEH Series  
Energy Efficiency Level V  
CEC 2008 and EISA 2007 Compliant  
Optional Inlet Connectors  
Class II Versions  
+60 °C Operating Temperature  
Compact Dimensions  
Low Cost  
B R A N D  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
• 0.5 A max VEH20  
1.0 A max VEH40  
• 45 A/90 A for 115 VAC/230 VAC,  
cold start at 25 °C  
Efficiency  
• 87% typical (average of measured values  
with output loads of 25%, 50%, 75%  
and 100%)  
Energy Efficiency  
Isolation  
• Level V  
• 3000 VAC Input to Output  
1500 VAC Input to Ground*  
500 VDC Output to Ground*  
*Not C2 version  
• VEH20: 63 kHz typical  
VEH40: 20 kHz - 60 kHz variable  
Inrush Current  
Earth Leakage Current • 0.75 mA at 240 VAC/50 Hz  
Power Factor  
• EN61000-3-2, Class A  
• Internal fuse fitted in line  
VEH20: T1 A, 250 V  
Switching Frequency  
MTBF  
Input Protection  
• >250 kHrs to MIL-HDBK-217F at 25 °C,GB  
VEH40: T3.15 A, 250 V  
No Load Input Power • <0.3 W  
Environmental  
Operating Temperature • 0 °C to +60 °C, derate from 100% power  
at +40 °C to 50% power at +60 °C  
Storage Temperature • -40 °C to +85 °C  
Output  
Output Voltage  
Minimum Load  
Hold Up Time  
• See table  
• No minimum load required  
• VEH20: 5 ms min, VEH40: 12 ms min,  
at full load & 110 VAC  
• 2 s max at full load 100 VAC  
• 2% deviation, recovery to within 1% of  
nominal in 500 µs for 50% load change  
• See table  
Cooling  
• Convection-cooled  
• 5-95% RH, non-condensing  
• 2000 m  
Operating Humidity  
Operating Altitude  
Shock  
Start Up Delay  
• 10 g, 10 ms on 3 axes  
Transient Response  
EMC & Safety  
Emissions  
Regulation  
• EN55022 level B conducted & radiated  
• EN61000-3-2 class A  
• EN61000-3-3  
• EN61000-4-2 level 3 Perf criteria A  
• EN61000-4-3 3 V/m Perf criteria A  
• EN61000-4-4 level 2 Perf criteria A  
Ripple & Noise  
• 1% pk-pk max, 20 MHz bandwidth  
Harmonic Current  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
Overvoltage Protection • Not fitted  
Overload Protection • 110-150%  
Short Circuit Protection • Trip & restart (hiccup mode), auto recovery  
Temperature  
Coefficient  
0.04%/°C  
Surge  
• EN61000-4-5 installation class 3  
Perf criteria A  
Conducted Immunity  
Magnetic Field  
• EN61000-4-6 level 2 Perf criteria A  
• EN61000-4-8 1 A/m Perf criteria A  
Dips & Interruptions  
• EN61000-4-11, 30% 10 ms, 60% 100 ms,  
100% 5000 ms Perf Criteria A, B, B  
Safety Approvals  
• EN60950-1, UL/cUL60950-1,  
Approved as Limited Power Source  
VEH20/40  
Models and Ratings  
Max Output Power  
Output Voltage(1)  
Output Current  
Total Regulation(2)  
Model Number  
15 W  
20 W  
20 W  
20 W  
20 W  
20 W  
25 W  
40 W  
40 W  
40 W  
40 W  
40 W  
5.0 VDC  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
48.0 VDC  
5.0 VDC  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
48.0 VDC  
3.00 A  
1.67 A  
1.33 A  
1.11 A  
0.83 A  
0.42 A  
5.00 A  
3.33 A  
2.67 A  
2.22 A  
1.67 A  
0.83 A  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
VEH20US05(3,4)  
VEH20US12(3,4)  
VEH20US15(3,4)  
VEH20US18(3,4)  
VEH20US24(3,4)  
VEH20US48(3,4)  
VEH40US05  
VEH40US12  
VEH40US15  
VEH40US18  
VEH40US24  
VEH40US48  
Notes  
1. Other output voltages available, contact sales for details  
2. Total regulation includes line regulation and load regulation.  
3. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add suffix ‘C6’ to model number, e.g. VEH20US12C6.  
4. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number e.g. VEH20US12C2  
Mechanical Details  
VEH20  
3.90 (99.0) For C8 and C6 inlet versions  
4.11 (104.0) for C14 inlet versions  
1.22 (31.0)  
1.22 (31.0)  
1.22 (31.0)  
0.02  
(0.5)  
0.02  
(0.5)  
0.02  
(0.5)  
AC INPUT  
IEC320-C8 INLET  
(Optional C2 Version)  
AC INPUT  
IEC320-C6 INLET  
(Optional C6 Version)  
AC INPUT  
IEC-320-C14 INLET  
VEH40  
1.19 (30.1)  
4.21 (107.0)  
0.02 (0.5)  
AC INPUT  
IEC320-C14 INLET  
Notes  
1. All dimensions are shown in inches (mm). Tolerance 0.04 ( 1.0) max.  
2. Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40  
3. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0).  
4. Output cable length is 48” (1220mm) approx.  
5. For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II  
6. For UK mains lead order part: UK-MAINS-IEC, for IEC320-C14 inlet, UK-MAINS-C5 for IEC320-C6 inlet, UK-MAINS-8 for Class II  
7. For US mains lead order part: US-MAINS-IEC, for IEC320-C14 inlet, US-MAINS-C5 for IEC320-C6 inlet, US-MAINS-8 for Class II  
02-May-14  

相关型号:

VEH40US12-L6

AC-DC Power Supplies
XPPOWER

VEH40US15

Energy Efficiency Level V
XPPOWER

VEH40US15-L6

AC-DC Power Supplies
XPPOWER

VEH40US18

Energy Efficiency Level V
XPPOWER

VEH40US18-L6

AC-DC Power Supplies
XPPOWER

VEH40US24

Energy Efficiency Level V
XPPOWER

VEH40US24-L6

AC-DC Power Supplies
XPPOWER

VEH40US48

Energy Efficiency Level V
XPPOWER

VEH40US48-L6

AC-DC Power Supplies
XPPOWER

VEH470M1VTR080100

ALUMINUM ELECTROLYTIC CAPACITORS VEH Series: Surface Mount Type, Low Impedance
RFE

VEH60US12

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER

VEH60US15

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER