VEH40US15-L6 [XPPOWER]

AC-DC Power Supplies;
VEH40US15-L6
型号: VEH40US15-L6
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies

文件: 总4页 (文件大小:557K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies  
VEH20/40-L6 Series  
20/40 Watt  
• Energy Efficiency Level VI  
xxx Series  
• Optional Inlet Connectors  
• Class II Versions  
• +60 °C Operating Temperature  
• Compact Dimensions  
• Low Cost  
B R A N D  
Dimensions:  
VEH20: 4.11 x 1.65 x 1.22” (104.0 x 42.0 x 31.0 mm)  
VEH40: 4.21 x 1.85 x 1.19” (107.0 x 47.0 x 30.1 mm)  
Models & Ratings  
Max Output Power  
Output Voltage(1)  
Output Current  
Efficiency(6)  
Total Regulation(2)  
Model Number  
15 W  
20 W  
20 W  
20 W  
20 W  
20 W  
25 W  
40 W  
40 W  
40 W  
40 W  
40 W  
5.0 VDC  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
48.0 VDC  
5.0 VDC  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
48.0 VDC  
3,00 A  
1.67 A  
1.33 A  
1.11 A  
0.83 A  
0.42 A  
5.00 A  
3.33 A  
2.67 A  
2.22 A  
1.67 A  
0.83 A  
83%  
87%  
87%  
87%  
87%  
91%  
85%  
88%  
88%  
88%  
88%  
89%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
VEH20US05-L6(3,4)  
VEH20US12-L6(3,4)  
VEH20US15-L6(3,4)  
VEH20US18-L6(3,4)  
VEH20US24-L6(3,4)  
VEH20US48-L6(3,4)  
VEH40US05-L6(5)  
VEH40US12-L6(5)  
VEH40US15-L6(5)  
VEH40US18-L6(5)  
VEH40US24-L6(5)  
VEH40US48-L6(5)  
Notes  
1. Other output voltages available, contact sales for details  
2. Total regulation includes line regulation and load regulation.  
3. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add  
suffix ‘C6’ to model number, e.g. VEH20US12-L6C6.  
5. VEH40USXX-L6 available with output negative connected to ground,  
add suffix -G.  
6. Minimum average of efficiencies measured at 25%, 50%, 75% and 100% load.  
4. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number  
e.g. VEH20US12-L6C2  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
264  
Units  
VAC  
Hz  
Notes & Conditions  
Input Voltage  
90  
47  
Input Frequency  
63  
0.5  
100 VAC, VEH20  
Input Current  
Inrush Current  
A
A
1.0  
100 VAC, VEH40  
45  
90  
115 VAC, cold start at 25 °C  
230 VAC, cold start at 25 °C  
EN61000-3-2, class A  
Power Factor  
No Load Input Power  
Input Protection  
0.1  
W
VEH20: Internal fuse fitted in line T1.0A/250 VAC, VEH40: Internal fuse fitted in line T3.15 A/250 VAC  
www.xppower.com  
1
AC-DC Power Supplies  
VEH20/40-L6 Series  
Output  
Characteristic  
Output Voltage  
Minimum Load  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
5
0
48  
V
A
See Models and Ratings table  
No minimum load required  
VEH20 at full load and 110 VAC  
VEH40 at full load and 110 VAC  
Full load and 100 VAC  
5
Hold Up Time  
ms  
s
12  
Start Up Delay  
Regulation  
2
1
See Models and Ratings table  
Recovery within 1% of nominal in 500 µs for 50% load  
change  
Transient Response  
Ripple & Noise  
2
% deviation  
Measured with 20 MHz bandwidth and 10 µF electrolytic  
capacitor in parallel with a 0.1 µF ceramic capacitor  
% pk-pk  
%
Overload Protection  
100  
150  
Short Circuit Protection  
Temperature Coefficient  
Trip and restart (hiccup mode) with auto recovely  
0.04  
%/˚C  
General  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Average of measured values with output loads of 25%,  
50%, 75% and 100%  
Efficiency  
Isolation  
87  
%
3000  
1500  
500  
VAC  
VAC  
VDC  
Input to Output  
Input to Ground (not C2 version)  
Output to Ground (not C2 version)  
63  
VEH20  
Switching Frequency  
Mean Time Between Failure  
Weight  
kHz  
kHrs  
lb (g)  
20  
60  
VEH40  
>250  
MIL-HDBK-217F at 25 °C GB  
0.37 (170)  
0.62 (260)  
VEH20  
VEH40  
Efficiency Curves  
VEH20US12  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac  
230Vac  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
VEH20US24  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac  
230Vac  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
www.xppower.com  
2
AC-DC Power Supplies  
VEH20/40-L6 Series  
Efficiency Curves  
VEH40US12-L6  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac  
230Vac  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
VEH40US24-L6  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac  
230Vac  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
Environmental  
Characteristic  
Operating Temperature  
Storage Temperature  
Operating Humidity  
Cooling  
Minimum  
Typical  
Maximum  
+60  
Units  
°C  
Notes & Conditions  
0
-40  
5
Derate from 100% load at +40 °C to 50% load at +60 °C  
+85  
°C  
95  
%
RH, non-condensing  
Convection convection  
10 g, 10 ms on 3 axes  
Shock  
EMC: Emissions  
Phenomenon  
Conducted  
Standard  
EN55022  
Test Level  
Notes & Conditions  
Level B  
Level B  
Class A  
Radiated  
EN55022  
Harmonics Current  
Voltage Flicker  
EN61000-3-2  
EN61000-3-3  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
3
Criteria  
Notes & Conditions  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
A
A
A
A
A
A
3 V/m  
Level 2  
Surges  
Installation Class 3  
Conducted Immunity  
Magnetic Fields  
Dips and Interruptions  
2
1 A/m  
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B  
www.xppower.com  
3
DC-DC Converter  
VEH20/40-L6 Series  
Safety Approvals  
Phenomenon  
Standard  
Notes  
EN  
UL  
EN60950-1  
UL/cUL60950-1  
Approved as limited power source (LPS)  
Mechanical Details  
VEH20-L6  
3.90 (99.0) For C8 and C6 inlet versions  
4.11 (104.0) for C14 inlet versions  
1.22 (31.0)  
1.22 (31.0)  
1.22 (31.0)  
0.02  
(0.5)  
0.02  
(0.5)  
0.02  
(0.5)  
AC INPUT  
IEC320-C8 INLET  
AC INPUT  
IEC320-C6 INLET  
AC INPUT  
IEC-320-C14 INLET  
(Optional C6 Version)  
(Optional C2 Version)  
VEH40-L6  
1.19 (30.1)  
4.21 (107.0)  
0.02 (0.5)  
AC INPUT  
IEC320-C14 INLET  
Notes  
1. All dimensions are shown in inches (mm). Tolerance 0.04 ( 1.0) max.  
2. Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40  
3. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0).  
4. Output cable length is 48” (1220mm) approx.  
5. For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II  
6. For UK mains lead order part: UK-MAINS-IEC, for IEC320-C14 inlet, UK-MAINS-C5 for IEC320-C6 inlet, UK-MAINS-8 for Class II  
7. For US mains lead order part: US-MAINS-IEC, for IEC320-C14 inlet, US-MAINS-C5 for IEC320-C6 inlet, US-MAINS-8 for Class II  
www.xppower.com  
15-Jun-16  

相关型号:

VEH40US18

Energy Efficiency Level V
XPPOWER

VEH40US18-L6

AC-DC Power Supplies
XPPOWER

VEH40US24

Energy Efficiency Level V
XPPOWER

VEH40US24-L6

AC-DC Power Supplies
XPPOWER

VEH40US48

Energy Efficiency Level V
XPPOWER

VEH40US48-L6

AC-DC Power Supplies
XPPOWER

VEH470M1VTR080100

ALUMINUM ELECTROLYTIC CAPACITORS VEH Series: Surface Mount Type, Low Impedance
RFE

VEH60US12

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER

VEH60US15

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER

VEH60US19

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER

VEH60US24

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER

VEH60US30

Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
XPPOWER