AC-DC Power Supplies
VEH20/40-L6 Series
20/40 Watt
• Energy Efficiency Level VI
xxx Series
• Optional Inlet Connectors
• Class II Versions
• +60 °C Operating Temperature
• Compact Dimensions
• Low Cost
B R A N D
Dimensions:
VEH20: 4.11 x 1.65 x 1.22” (104.0 x 42.0 x 31.0 mm)
VEH40: 4.21 x 1.85 x 1.19” (107.0 x 47.0 x 30.1 mm)
Models & Ratings
Max Output Power
Output Voltage(1)
Output Current
Efficiency(6)
Total Regulation(2)
Model Number
15 W
20 W
20 W
20 W
20 W
20 W
25 W
40 W
40 W
40 W
40 W
40 W
5.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
5.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
3,00 A
1.67 A
1.33 A
1.11 A
0.83 A
0.42 A
5.00 A
3.33 A
2.67 A
2.22 A
1.67 A
0.83 A
83%
87%
87%
87%
87%
91%
85%
88%
88%
88%
88%
89%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
VEH20US05-L6(3,4)
VEH20US12-L6(3,4)
VEH20US15-L6(3,4)
VEH20US18-L6(3,4)
VEH20US24-L6(3,4)
VEH20US48-L6(3,4)
VEH40US05-L6(5)
VEH40US12-L6(5)
VEH40US15-L6(5)
VEH40US18-L6(5)
VEH40US24-L6(5)
VEH40US48-L6(5)
Notes
1. Other output voltages available, contact sales for details
2. Total regulation includes line regulation and load regulation.
3. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add
suffix ‘C6’ to model number, e.g. VEH20US12-L6C6.
5. VEH40USXX-L6 available with output negative connected to ground,
add suffix -G.
6. Minimum average of efficiencies measured at 25%, 50%, 75% and 100% load.
4. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number
e.g. VEH20US12-L6C2
Input
Characteristic
Minimum
Typical
Maximum
264
Units
VAC
Hz
Notes & Conditions
Input Voltage
90
47
Input Frequency
63
0.5
100 VAC, VEH20
Input Current
Inrush Current
A
A
1.0
100 VAC, VEH40
45
90
115 VAC, cold start at 25 °C
230 VAC, cold start at 25 °C
EN61000-3-2, class A
Power Factor
No Load Input Power
Input Protection
0.1
W
VEH20: Internal fuse fitted in line T1.0A/250 VAC, VEH40: Internal fuse fitted in line T3.15 A/250 VAC
www.xppower.com
1
AC-DC Power Supplies
VEH20/40-L6 Series
Output
Characteristic
Output Voltage
Minimum Load
Minimum
Typical
Maximum
Units
Notes & Conditions
5
0
48
V
A
See Models and Ratings table
No minimum load required
VEH20 at full load and 110 VAC
VEH40 at full load and 110 VAC
Full load and 100 VAC
5
Hold Up Time
ms
s
12
Start Up Delay
Regulation
2
1
See Models and Ratings table
Recovery within 1% of nominal in 500 µs for 50% load
change
Transient Response
Ripple & Noise
2
% deviation
Measured with 20 MHz bandwidth and 10 µF electrolytic
capacitor in parallel with a 0.1 µF ceramic capacitor
% pk-pk
%
Overload Protection
100
150
Short Circuit Protection
Temperature Coefficient
Trip and restart (hiccup mode) with auto recovely
0.04
%/˚C
General
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Average of measured values with output loads of 25%,
50%, 75% and 100%
Efficiency
Isolation
87
%
3000
1500
500
VAC
VAC
VDC
Input to Output
Input to Ground (not C2 version)
Output to Ground (not C2 version)
63
VEH20
Switching Frequency
Mean Time Between Failure
Weight
kHz
kHrs
lb (g)
20
60
VEH40
>250
MIL-HDBK-217F at 25 °C GB
0.37 (170)
0.62 (260)
VEH20
VEH40
Efficiency Curves
VEH20US12
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
VEH20US24
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
www.xppower.com
2
AC-DC Power Supplies
VEH20/40-L6 Series
Efficiency Curves
VEH40US12-L6
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
VEH40US24-L6
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
Environmental
Characteristic
Operating Temperature
Storage Temperature
Operating Humidity
Cooling
Minimum
Typical
Maximum
+60
Units
°C
Notes & Conditions
0
-40
5
Derate from 100% load at +40 °C to 50% load at +60 °C
+85
°C
95
%
RH, non-condensing
Convection convection
10 g, 10 ms on 3 axes
Shock
EMC: Emissions
Phenomenon
Conducted
Standard
EN55022
Test Level
Notes & Conditions
Level B
Level B
Class A
Radiated
EN55022
Harmonics Current
Voltage Flicker
EN61000-3-2
EN61000-3-3
EMC: Immunity
Phenomenon
Standard
Test Level
3
Criteria
Notes & Conditions
ESD Immunity
Radiated Immunity
EFT/Burst
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
A
A
A
A
A
A
3 V/m
Level 2
Surges
Installation Class 3
Conducted Immunity
Magnetic Fields
Dips and Interruptions
2
1 A/m
EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B
www.xppower.com
3
DC-DC Converter
VEH20/40-L6 Series
Safety Approvals
Phenomenon
Standard
Notes
EN
UL
EN60950-1
UL/cUL60950-1
Approved as limited power source (LPS)
Mechanical Details
VEH20-L6
3.90 (99.0) For C8 and C6 inlet versions
4.11 (104.0) for C14 inlet versions
1.22 (31.0)
1.22 (31.0)
1.22 (31.0)
0.02
(0.5)
0.02
(0.5)
0.02
(0.5)
AC INPUT
IEC320-C8 INLET
AC INPUT
IEC320-C6 INLET
AC INPUT
IEC-320-C14 INLET
(Optional C6 Version)
(Optional C2 Version)
VEH40-L6
1.19 (30.1)
4.21 (107.0)
0.02 (0.5)
AC INPUT
IEC320-C14 INLET
Notes
1. All dimensions are shown in inches (mm). Tolerance 0.04 ( 1.0) max.
2. Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40
3. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0).
4. Output cable length is 48” (1220mm) approx.
5. For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II
6. For UK mains lead order part: UK-MAINS-IEC, for IEC320-C14 inlet, UK-MAINS-C5 for IEC320-C6 inlet, UK-MAINS-8 for Class II
7. For US mains lead order part: US-MAINS-IEC, for IEC320-C14 inlet, US-MAINS-C5 for IEC320-C6 inlet, US-MAINS-8 for Class II
www.xppower.com
15-Jun-16
相关型号:
VEH470M1VTR080100
ALUMINUM ELECTROLYTIC CAPACITORS VEH Series: Surface Mount Type, Low Impedance
RFE
©2020 ICPDF网 联系我们和版权申明