ASDXAVX002BASA3

更新时间:2025-04-27 12:39:08
品牌:HONEYWELL
描述:Low Pressure and Ultra-Low Pressure Digital Output,2 Total Error Band, 10 Inches H20 to 100 psi

ASDXAVX002BASA3 概述

Low Pressure and Ultra-Low Pressure Digital Output,2 Total Error Band, 10 Inches H20 to 100 psi 低压和超低压数字输出, 2总误差带, 10英寸水柱到100磅

ASDXAVX002BASA3 数据手册

通过下载ASDXAVX002BASA3数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
±
DESCRIPTION  
The ASDX Series is a Silicon Pressure Sensor offering either  
an I2C or SPI digital interface for reading pressure over the  
specified full scale pressure span and temperature range.  
These sensors are available to measure absolute, differential  
and gage pressures. The absolute versions have an internal  
vacuum reference and an output value proportional to absolute  
pressure. Differential versions allow application of pressure to  
either side of the sensing diaphragm. Gage versions are  
referenced to atmospheric pressure and provide an output  
proportional to pressure variations from atmosphere.  
The ASDX is fully calibrated and temperature compensated for  
sensor offset, sensitivity, temperature effects and non-linearity  
using an on-board Application Specific Integrated Circuit  
(ASIC). Calibrated output values for pressure are updated at  
approximately 1 kHz.  
The ASDX Series sensors are intended for use with non-  
corrosive, non-ionic working fluids such as air and dry gases.  
They are designed and manufactured according to standards  
in ISO 9001.  
The standard ASDX is calibrated over the temperature range  
of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized  
for operation from a single power supply of either 3.3 Vdc or  
5.0 Vdc.  
FEATURES  
POTENTIAL APPLICATIONS  
Flow calibrators  
Output options: I2C- or SPI-compatible 12-bit digital  
Precision ASIC conditioning and temperature  
compensated over 0 °C to 85 °C [32 °F to 185 °F]  
temperature range  
Ventilation and air flow monitors  
Gas flow instrumentation  
Sleep apnea monitoring and therapy equipment  
Barometry  
Low operating voltage  
Absolute, differential and gage types  
Pressure ranges from 10 inches H20 to 100 psi  
Standard calibrations in inches H20, cm H20, psi, mbar,  
bar, kPa  
Pneumatic controls  
HVAC  
Total error band of ±2.0% of full scale span maximum  
RoHS compliant  
Table 1. Absolute Maximum Ratings1  
Parameter  
Supply voltage (Vsupply)  
Voltage to any pin  
Min  
-0.3  
-0.3  
Max  
6.0  
Vsupply + 0.3  
Unit  
Vdc  
Vdc  
Digital clock frequency:  
I2C  
100  
50  
400  
800  
kHz  
SPI  
ESD susceptibility (human body model)  
Storage temperature  
Lead temperature (2 s to 4 s)  
External capacitance between Vsupply and ground2  
3
-50 [-58]  
kV  
125 [257]  
250 [482]  
470  
°C [°F]  
°C [°F]  
nF  
100  
Table 2. Operating Specifications  
Parameter  
Min.  
Typ.  
Max.  
Unit  
Supply voltage: (Vsupply)3  
3.3 Vdc  
3.0  
4.75  
3.34  
5.04  
3.6  
5.25  
Vdc  
5.0 Vdc  
Sensors are either 3.3 Vdc or 5.0 Vdc per the Order Guide (see Figure 1).  
Supply current  
2.0  
0 [32]  
-20 [-4]  
3.5  
5.0  
85 [185]  
105 [221]  
mA  
°C [°F]  
°C [°F]  
Compensated temperature range5  
Operating temperature range6  
Overpressure7  
2X operating pressure range minimum  
3X operating pressure range minimum  
Burst pressure8  
Startup time (power up to data ready)  
Response time  
0.8  
1
2.8  
0.46  
7.3  
0.2  
2.0  
ms  
ms  
I2C or SPI voltage level low  
I2C or SPI voltage level high  
Pull-up on SDA and SCL (I2C output only)  
Total error band9  
Vsupply  
Vsupply  
kOhm  
%FSS10  
bits  
Output resolution  
12  
Table 3. Environmental Specifications  
Parameter  
Humidity  
Vibration  
Shock  
Characteristic  
0% to 95% RH non-condensing  
10 G at 20 Hz to 2000 Hz  
100 G for 11 ms  
Life  
1 million cycles minimum  
Table 4. Wetted Materials11  
Parameter  
Covers  
Port 1 (Pressure Port)12  
glass-filled PBT  
silicone  
Port 2 (Reference Port)12  
glass-filled PBT  
silicone and epoxy  
Adhesives  
Electronic components  
Notes:  
silicon and glass  
silicon, glass, and gold  
1. Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device.  
2. An external bypass capacitor is required across the supply voltage (Pins 6 and 3 see Figure 4) as close to the sensor supply pin as possible  
for correct sensor operation.  
3. Ratiometricity of the sensor (the ability of the output to scale to the input voltage) is achieved within the specified operating voltage for each  
option. Other custom supply voltages are available, please contact Honeywell Customer Service.  
4. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin may cause electrical failure.  
5. The compensated temperature range is the temperature range (or ranges) over which the sensor will produce an output proportional to  
pressure within the specified performance limits.  
6. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not  
remain within the specified performance limits.  
7. Overpressure is the maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to  
the operating pressure range. Exposure to higher pressures may cause permanent damage to the product.  
8. Burst pressure is the maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product  
should not be expected to function after exposure to any pressure beyond the burst pressure.  
9. Total error band is the maximum deviation in output from ideal transfer function over the entire compensated temperature and pressure range.  
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect  
on span and thermal hysteresis. Specification units are in percent of full scale span (%FSS).  
10. Full scale span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of  
the pressure range.  
11. Consult Honeywell Customer Service for detailed material information.  
12. For AC pressure port configuration, the “pressure” and “reference” ports are reversed.  
2
www.honeywell.com/sensing  
Figure 1. Nomenclature and Order Guide  
Package Selection13  
Calibration Selection  
_ _  
X _ _ _ _ _  
_
_
_
ASDX  
Series  
Power Supply Voltage  
3 = 3.3 Vdc  
5 = 5.0 Vdc  
Pressure Port  
Transfer Function Limits14  
A = 10% to 90% calibration  
B = 5% to 95% calibration  
AV = Axial port on top, vented cover on bottom  
Output Type15  
S = SPI  
2
2 = I C, Address 0x28  
2
3 = I C, Address 0x38  
2
4 = I C, Address 0x48  
2
5 = I C, Address 0x58  
2
6 = I C, Address 0x68  
RR = Radial port on top, radial port on bottom  
2
7 = I C, Address 0x78  
Pressure Range16, 17, 18  
Gage  
Differential  
Absolute  
005ND = ±5 in H2O  
010ND = ±10 in H2O  
-
-
-
010NG = 10 in H2O  
AC = Axial port, sealed cover (commonly used  
015CD = ±15 cm H2O  
025CD = ±25 cm H2O  
-
-
for absolute)  
-
025CG = 25 cm H2O  
001PD = ±1 psi  
005PD = ±5 psi  
015PD = ±15 psi  
030PD = ±30 psi  
-
-
-
001PG = 1 psi  
005PG = 5 psi  
015PG = 15 psi  
030PG = 30 psi  
100PG = 100 psi  
015PA = 15 psi  
030PA = 30 psi  
100PA = 100 psi  
015MD = ±15 mbar  
025MD = ±25 mbar  
050MD = ±50 mbar  
100MD = ±100 mbar  
200MD = ±200 mbar  
500MD = ±500 mbar  
-
-
-
-
-
-
-
RV = Radial port, single  
025MG = 25 mbar  
050MG = 50 mbar  
100MG = 100 mbar  
200MG = 200 mbar  
500MG = 500 mbar  
001BD = ±1 bar  
002BD = ±2 bar  
-
001BA = 1 bar  
002BA = 2 bar  
007BA = 7 bar  
001BG = 1 bar  
002BG = 2 bar  
007BG = 7 bar  
003KD = ±3 kPa  
004KD = ±4 kPa  
005KD = ±5 kPa  
010KD = ±10 kPa  
020KD = ±20 kPa  
050KD = ±50 kPa  
100KD = ±100 kPa  
200KD = ±200 kPa  
-
-
-
-
-
-
-
003KG = 3 kPa  
004KG = 4 kPa  
005KG = 5 kPa  
010KG = 10 kPa  
020KG = 20 kPa  
050KG = 50 kPa  
100KG = 100 kPa  
200KG = 200 kPa  
700KG = 700 kPa  
Future Option  
100KA = 100 kPa  
200KA = 200 kPa  
700KA = 700 kPa  
Notes:  
13. Other package combinations are possible, please contact Honeywell Customer Service.  
14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.)  
and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical  
representation of each calibration. For the 12-bit digital output, Table 6 provides the output of the sensor at significant percentages. These  
outputs are valid at the rated input voltage of the sensor.  
15. The output type defines which communication protocol the sensor uses to communicate. Available protocols are I2C or half duplex SPI (sensor  
acts only as a slave). This communication protocol is not field selectable, and must be defined when ordering the sensor.  
16. Custom pressure ranges are available, please contact Honeywell Customer Service.  
17. The pressure units (inches H20, cm H20, psi, mbar, bar, kPa) define the units used during calibration and in the application.  
18. See Table 5 for an explanation of sensor types.  
Honeywell Sensing and Control  
3
Table 5. Sensor Types  
Type  
Description  
Absolute  
Gage  
Output is proportional to difference between applied pressure and built-in reference to vacuum (zero pressure).  
Output is proportional to difference between applied pressure and atmospheric (ambient) pressure.  
Output is proportional to difference between pressure applied to each of the pressure ports (Port 1 Port 2).  
Differential  
Figure 2. Transfer Functions and Limits  
A Calibration, 10% to 90%  
B Calibration, 5% to 95%  
Table 6. Sensor Output at Significant Percentages  
% Output  
0%  
Digital Counts (dec)  
Digital Counts (hex)  
0x0000  
0
5%  
819  
0x0333  
10%  
1638  
8192  
14746  
15565  
16383  
0x0666  
0x2000  
0x399A  
0x3CCD  
0x3FFF  
50%  
90%  
95%  
100%  
Figure 3. Completed Catalog Listing Example  
ASDXAVX001PG2A3:  
ASDXAVX001PG2A3 Output vs Pressure  
AV pressure port, 1 psi gage, I2C output  
(Address 0x28), 10% to 90% calibration  
at 3.3 Vdc operation.  
4
www.honeywell.com/sensing  
Figure 4. Dimensional Drawings (For reference only: mm [in].)  
AV Package (Legacy G2)  
RR Package (Legacy D4)  
RV Package  
AC Package (Legacy A2)  
Table 7. Pinout  
I2C  
SPI  
Pin  
1
Definition  
Type  
digital I/O  
Description  
serial bidirectional data;  
data is clocked in or out on  
clock edge of SCL  
serial clock input; used to  
clock data on SDA  
power supply ground  
do not connect in the  
application  
Pin  
1
Definition  
MISO  
Type  
digital output  
Description  
“Master In Slave Out” - serial  
output data; data is clocked  
out on clock edge of SCK  
serial clock input; used to  
clock data on MISO  
power supply ground  
do not connect in the  
application  
SDA  
2
SCL  
digital input  
2
SCK  
digital input  
3
4
GND  
N/C  
supply  
not used  
3
4
GND  
N/C  
supply  
not used  
5
SS  
digital output  
interrupt signal (conversion  
complete output)  
5
SS  
digital input  
slave select  
6
7
Vsupply  
N/C  
supply  
not used  
power supply source  
do not connect in the  
application  
6
7
Vsupply  
N/C  
supply  
not used  
power supply source  
do not connect in the  
application  
8
N/C  
not used  
do not connect in the  
application  
8
N/C  
not used  
do not connect in the  
application  
Honeywell Sensing and Control  
5
WARNING  
WARNING  
PERSONAL INJURY  
MISUSE OF DOCUMENTATION  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Failure to comply with these instructions could result  
in death or serious injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
Asia Pacific  
Europe  
+65 6355-2828; +65 6445-3033 Fax  
+44 (0) 1698 481481; +44 (0) 1698 481676 Fax  
+1-305-805-8188; +1-305-883-8257 Fax  
+1-800-537-6945; +1-815-235-6847  
+1-815-235-6545 Fax  
Latin America  
USA/Canada  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008095-11-EN IL50 GLO Printed in USA  
July 2010  
Copyright © 2010 Honeywell International Inc. All rights reserved.  
Golden Valley, MN 55422  
www.honeywell.com/sensing  

ASDXAVX002BASA3 相关器件

型号 制造商 描述 价格 文档
ASDXAVX002BD2B5 HONEYWELL Peizoresistive Sensor, Differential, -29.007Psi Min, 29.007Psi Max, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, PACKAGE-8 获取价格
ASDXAVX002BD4A3 HONEYWELL Peizoresistive Sensor, Differential, -29.007Psi Min, 29.007Psi Max, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, PACKAGE-8 获取价格
ASDXAVX002BD4A5 HONEYWELL Peizoresistive Sensor, Differential, -29.007Psi Min, 29.007Psi Max, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, PACKAGE-8 获取价格
ASDXAVX002BD7B3 HONEYWELL Peizoresistive Sensor, Differential, -29.007Psi Min, 29.007Psi Max, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, PACKAGE-8 获取价格
ASDXAVX002BDAA3 HONEYWELL ASDX Series Silicon Pressure Sensors 获取价格
ASDXAVX002BDAA5 HONEYWELL ASDX Series Silicon Pressure Sensors 获取价格
ASDXAVX002BDAB3 HONEYWELL ASDX Series Silicon Pressure Sensors 获取价格
ASDXAVX002BDAB5 HONEYWELL ASDX Series Silicon Pressure Sensors 获取价格
ASDXAVX002BDSA3 HONEYWELL Low Pressure and Ultra-Low Pressure Digital Output,2 Total Error Band, 10 Inches H20 to 100 psi 获取价格
ASDXAVX002BDSB3 HONEYWELL Peizoresistive Sensor, Differential, -29.007Psi Min, 29.007Psi Max, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, PACKAGE-8 获取价格

ASDXAVX002BASA3 相关文章

  • 6 月上海@AutoSEMI 与 AutoPEPS 2025 峰会,双核驱动汽车「芯」与「无感」未来
    2025-04-29
    14
  • EMC 设计:滤波、接地、屏蔽及 PCB 布局的专业解析
    2025-04-29
    14
  • 芯片高温危机:探寻高效散热的新路径
    2025-04-29
    16
  • 拆解小米充电器,国产芯方案高性价比揭秘
    2025-04-29
    15
  • Hi,有什么可以帮您? 在线客服 或 微信扫码咨询