Temperature Sensor Hub and Fan Controller  
Data Sheet  
ADT7470  
FEATURES  
Monitors up to 10 remote temperature sensors  
Monitors and controls speed of up to 4 fans independently  
PWM outputs drive each fan under software control  
GENERAL DESCRIPTION  
The ADT74701 controller is a multichannel temperature sensor  
and PWM fan controller and fan speed monitor for systems  
requiring active cooling. It is designed to interface directly to  
an I2C® bus. The ADT7470 can monitor up to 10 daisy-chained  
TMP05 temperature sensors. It can also monitor and control  
the speed of four fans, in automatic or in manual control loops.  
FULL_SPEED  
input allows fans to be blasted to maximum  
speed by external hardware  
SMBALERT  
interrupt signals failures to system controller  
Three-state ADDR pin allows up to 3 devices on a single bus  
Temperature decoder interprets TMP05 temperature sensors  
and communicates values over I2C bus  
Limit comparison of all monitored values  
Supports fast I2C standard (400 kHz max)  
Meets SMBus 2.0 electrical specifications  
(fully SMBus 1.1-compliant)  
FULL_SPEED  
A
input is provided to allow the fans to be  
blasted to maximum speed, via external hardware control,  
under extreme thermal conditions or on system startup. An  
SMBALERT  
interrupt communicates error conditions such as  
fan under speed and over temperature measurements to the  
system service processor. Individual error conditions can then  
be read from status registers over the I2C bus.  
APPLICATIONS  
Servers  
Networking and telecommunications equipment  
Desktops  
FUNCTIONAL BLOCK DIAGRAM  
SMBALERT  
SDA SCL  
ADDR  
ADT7470  
SMBus  
ADDRESS  
SELECTION  
SERIAL BUS  
INTERFACE  
FULL_SPEED  
PWM1  
ADDRESS  
POINTER  
REGISTER  
PWM  
REGISTERS  
AND  
AUTOMATIC  
FAN SPEED  
CONTROL  
PWM  
CONFIG  
REGISTERS  
PWM2  
PWM3  
PWM4  
CONTROLLERS  
INTERRUPT  
MASKING  
TACH1  
TACH2  
TACH3  
TACH4  
FAN SPEED  
COUNTERS  
INTERRUPT  
STATUS  
REGISTERS  
TMP_START  
TMP_IN  
LIMIT  
COMPARATORS  
TEMPERATURE  
DECODER  
VALUE AND  
LIMIT  
REGISTERS  
Figure 1.  
1 Protected by Patent Numbers US6,169,442, US6,097,239, US5,982,221, US5,867,012. Other patents pending.  
Rev. E Document Feedback  
Information furnished by Analog Devices is believed to be accurate and reliable. However, no  
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other  
rightsof third parties that may result fromits use. Specifications subject to change without notice. No  
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.  
Trademarks andregisteredtrademarks are the property of their respective owners.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700 ©2004–2013 Analog Devices, Inc. All rights reserved.  
Technical Support  
www.analog.com  
 
 
 
 
ADT7470  
Data Sheet  
TABLE OF CONTENTS  
Temperature Data Format......................................................... 14  
Temperature Measurement Limits........................................... 15  
Thermal Zones for Automatic Fan Control............................ 15  
Limit and Status Registers ............................................................. 16  
Limit Values ................................................................................ 16  
Temperature Limits.................................................................... 16  
Fan Speed Limits ........................................................................ 16  
Out-of-Limit Comparisons....................................................... 16  
Status Registers ........................................................................... 17  
Features .............................................................................................. 1  
Applications....................................................................................... 1  
General Description ......................................................................... 1  
Functional Block Diagram .............................................................. 1  
Revision History ............................................................................... 2  
Specifications..................................................................................... 3  
Serial Bus Timing Specifications................................................ 4  
Absolute Maximum Ratings............................................................ 5  
Thermal Characteristics .............................................................. 5  
ESD Caution.................................................................................. 5  
Pin Configuration and Function Descriptions............................. 6  
Functional Description.................................................................... 7  
General Description..................................................................... 7  
Configuration Register 1 (Address 0x40).................................. 7  
Configuration Register 2 (Address 0x74).................................. 7  
ID Registers................................................................................... 7  
General-Purpose I/O Pins (Open Drain)...................................... 8  
SMBus/I2C Serial Interface.............................................................. 9  
Address Selection ......................................................................... 9  
Serial Bus Protocol ....................................................................... 9  
Write Operations ........................................................................ 11  
Read Operations ......................................................................... 12  
SMBus Timeout .......................................................................... 12  
Temperature Measurement Using TMP05/TMP06 ................... 13  
Measuring Temperature ............................................................ 13  
Temperature ReadBack By the Host ........................................ 14  
SMBALERT  
Interrupt................................................................ 18  
Fan Drive Using PWM Control.................................................... 20  
High Frequency Fan Drive........................................................ 20  
Low Frequency Fan Drive......................................................... 20  
Setting the Fan Drive Frequency.............................................. 21  
Inverted PWM Output .............................................................. 21  
Fan Full Speed Function............................................................ 21  
Fan Speed Measurement................................................................ 22  
Tach Inputs.................................................................................. 22  
Fan Speed Measurement ........................................................... 23  
Manual Fan Speed Control ........................................................... 25  
Setting the PWM Duty Cycle ................................................... 25  
Automatic Fan Speed Control ...................................................... 26  
Register Map ................................................................................... 27  
Detailed Register Descriptions ..................................................... 29  
Outline Dimensions....................................................................... 39  
Ordering Guide .......................................................................... 39  
REVISION HISTORY  
4/13—Rev. D to Rev. E  
Additions to Manual Fan Speed Control Section ...................... 25  
Additions to Automatic Fan Speed Control Section ................. 26  
Changed Input Low Voltage, VIL from 0.4 V to 1.0 V and Added  
Test Conditions/Comments; Table 1.............................................. 3  
7/05—Rev. A to Rev. B  
References to PWM_IN changed to TMP_IN ...............Universal  
Changes to TMIN Registers Section ..................................................7  
Added Address Selection Section....................................................7  
Added Thermal Zones Section..................................................... 12  
Added Temperature Reading Section.......................................... 13  
Added Note to Table 39 ................................................................. 32  
3/13—Rev. C to Rev. D  
Changes to Calculating Fan Speed and Tachometer Limits  
Section.............................................................................................. 24  
Changes to Bit 3, Table 43.............................................................. 35  
Updated Outline Dimensions....................................................... 39  
7/09—Rev. B to Rev. C  
2/05—Rev. 0 to Rev. A  
Changes to Functional Description Section ................................. 7  
Added Temperature Data Format Section .................................. 14  
Additions to Fan Drive Using PWM Control Section............... 20  
Added General-Purpose I/O Pins (Open Drain) Section......... 11  
11/04—Revision 0: Initial Version  
Rev. E | Page 2 of 40  
 
Data Sheet  
ADT7470  
SPECIFICATIONS  
TA = −40oC to +125oC, VCC = 3.0 V to 5.5 V, unless otherwise noted.  
Table 1.  
Parameter1, 2, 3, 4, 5  
POWER SUPPLY1  
Supply Voltage  
Supply Current, ICC  
Standby Current, ICC  
FAN RPM-TO-DIGITAL CONVERTER  
Accuracy  
Min  
Typ  
Max  
Unit  
Test Conditions/Comments  
3.0  
3.3  
0.5  
4
5.5  
0.8  
V
mA  
µA  
12  
%
Full-Scale Count  
Nominal Input RPM  
65,535  
109  
329  
5,000  
10,000  
RPM  
RPM  
RPM  
RPM  
Fan count = 0xBFFF  
Fan count = 0x3FFF  
Fan count = 0x0438  
Fan count = 0x021C  
OPEN-DRAIN DIGITAL OUTPUTS, PWM1 to PWM4, SMBALERT  
Output Low Voltage, VOL  
High Level Output Current, IOH  
OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA)  
Output Low Voltage, VOL  
High Level Output Current, IOH  
SMBus DIGITAL INPUTS (SCL, SDA)  
Input High Voltage, VIH  
0.4  
1
V
µA  
IOUT = –8.0 mA, VCC = +3.3 V  
VOUT = VCC  
0.1  
0.1  
0.4  
1
V
µA  
IOUT = –4.0 mA, VCC = +3.3 V  
VOUT = VCC  
2.4  
2.4  
V
V
mV  
Input Low Voltage, VIL  
Hysteresis  
1.0  
0.8  
VCC = 3.3 V  
500  
50  
DIGITAL INPUT LOGIC LEVELS (TACH INPUTS, FULL_SPEED, GPIO)  
Input High Voltage, VIH  
Input Low Voltage, VIL  
V
V
Hysteresis  
mV p-p  
DIGITAL INPUT LOGIC LEVELS (TMP_IN)  
Input High Voltage, VIH  
Input Low Voltage, VIL  
VDD – 0.3  
–5  
V
V
0.4  
5
DIGITAL INPUT CURRENT  
Input High Current, IIH  
Input Low Current, IIL  
Input Capacitance, CIN  
µA  
µA  
pF  
VIN = VCC  
VIN = 0  
5
1 VDD should never be floated in the presence of SCL/SDA activity. Charge injection can be sufficient to induce approximately 0.6 V on VDD.  
2 All voltages are measured with respect to GND, unless otherwise specified.  
3 Typical values are at %A = 25°C and represent the most likely parametric norm.  
4 Logic inputs accept input high voltages up to 5 V even when the device is operating at supply voltages below 5 V.  
5 Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.0 V for a rising edge.  
Rev. E | Page 3 of 40  
 
ADT7470  
Data Sheet  
SERIAL BUS TIMING SPECIFICATIONS  
Table 2.  
Parameter1, 2, 3, 4, 5  
Min  
Typ  
Max  
Unit  
Test Conditions/Comments  
SERIAL BUS TIMING  
Clock Frequency, fSCLK  
Glitch Immunity, tSW  
Bus Free Time, tBUF  
Start Setup Time, tSU;STA  
Start Hold Time, tHD;STA  
SCL Low Time, tLOW  
SCL High Time, tHIGH  
SCL, SDA Rise Time, tr  
SCL, SDA Fall Time, tf  
Data Setup Time, tSU;DAT  
Detect Clock Low Timeout, tTIMEOUT  
400  
kHz  
ns  
μs  
ns  
ns  
μs  
μs  
ns  
ns  
ns  
ms  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
See Figure 2  
50  
1.3  
600  
600  
1.3  
0.6  
300  
300  
100  
25  
28  
31  
Can be optionally disabled,  
via Configuration Register 1  
(see Table 6)  
1 VDD should never be floated in the presence of SCL/SDA activity. Charge injection can be sufficient to induce approximately 0.6 V on VDD.  
2 All voltages are measured with respect to GND, unless otherwise specified.  
3 Typical values are at %A = 25°C and represent the most likely parametric norm.  
4 Logic inputs accept input high voltages up to 5 V even when the device is operating at supply voltages below 5 V.  
5 Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.0 V for a rising edge.  
tR  
tF  
tHD;STA  
tLOW  
SCL  
SDA  
tHIGH  
tSU;STA  
tSU;STO  
tHD;STA  
tHD;DAT  
tSU;DAT  
tBUF  
P
S
S
P
Figure 2. Serial Bus Timing Diagram  
Rev. E | Page 4 of 40  
 
 
Data Sheet  
ADT7470  
ABSOLUTE MAXIMUM RATINGS  
Table 3.  
Parameter  
Stresses above those listed under Absolute Maximum Ratings  
may cause permanent damage to the device. This is a stress  
rating only; functional operation of the device at these or any  
other conditions above those indicated in the operational  
section of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods may affect  
device reliability.  
Rating  
Positive Supply Voltage (VCC)  
Voltage on Any TACH or PWM Pin  
Voltage on Any Input or Output Pin  
6.5 V  
–0.3 V to +6.5 V  
–0.3 V to VCC + 0.3 V  
Maximum Junction Temperature (TJ max) 150°C  
Storage Temperature Range  
Lead Temperature, Soldering  
Vapor Phase, 60 sec  
Infrared, 15 sec  
ESD Rating (HBM)  
–65°C to +150°C  
ESD CAUTION  
215°C  
200°C  
3000 V  
THERMAL CHARACTERISTICS  
16-Lead QSOP Package:  
θ
θ
JA = 105°C/W  
JC = 39°C/W  
Rev. E | Page 5 of 40  
 
 
 
ADT7470  
Data Sheet  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
16  
15  
14  
13  
12  
11  
10  
9
SCL  
1
2
3
4
5
6
7
8
SDA  
GND  
PWM1  
V
ADT7470  
TOP VIEW  
(Not to Scale)  
SMBALERT  
CC  
TACH3  
PWM2  
TACH1  
TACH2  
PWM3  
FULL_SPEED/TMP_START  
TMP_IN  
ADDR  
PWM4  
TACH4  
Figure 3. Pin Configuration  
Table 4. Pin Function Descriptions  
Pin No. Mnemonic Description  
1
2
3
4
5
SCL  
GND  
VCC  
TACH3  
PWM2  
Digital Input (Open Drain). SMBus serial clock input. Requires SMBus pull-up, typically 2k2Ω.  
Ground Pin.  
Power Supply Pin.  
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 3.  
Digital I/O (Open Drain). Requires 10 kΩ typical pull-up. Pulse-width modulated output to control  
the speed of Fan 2. Can be configured as GPIO by setting Bit 0x7F[2] = 1.  
6
7
8
TACH1  
TACH2  
PWM3  
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 1.  
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 2.  
Digital I/O (Open Drain). Pulse-width modulated output to control the speed of Fan 3.  
Requires 10 kΩ typical pull-up. Can be configured as GPIO by setting Bit 0x7F[1] = 1.  
9
10  
TACH4  
PWM4  
Digital Input (Open Drain). Fan tachometer input to measure the speed of Fan 4.  
Digital I/O (Open Drain). Pulse-width modulated output to control the speed of Fan 4.  
Requires 10 kΩ typical pull-up. Can be configured as GPIO by setting Bit 0x7F[0] = 1.  
11  
12  
ADDR  
TMP_IN  
Three-state Input. Used to set the SMBus device address.  
Digital Input (Open Drain). PWM input to PWM processing engine that interprets daisy-chained output  
from multiple TMP05 temperature sensors. Readings from individual TMP05 temperature sensors are  
available by reading the temperature reading registers over the SMBus.  
13  
13  
14  
15  
16  
FULL_SPEED  
TMP_START  
SMBALERT  
PWM1  
Digital Input Active Low (Open Drain). This input blasts the fans to maximum speed when the pin is pulled low  
externally. Do not leave pin 13 open when not I use, tie to VCC.  
Digital Output (Open Drain). This pin can be used as an output to start daisy-chained temperature  
measurements from TMP05 or TMP06 temperature sensors. Requires 10 kΩ typical pull-up.  
Digital Output Active Low (Open Drain). This pin can be reconfigured as an SMBALERT interrupt output  
to signal out-of-limit conditions such as fan failures.  
Digital I/O (Open Drain). Pulse-width modulated output to control the speed of Fan 1.  
Requires 10 kΩ typical pull-up. Can be configured as GPIO by setting Bit 0x7F[3] = 1.  
SDA  
Digital I/O (Open Drain). SMBus bidirectional serial data. Requires SMBus pull-up, typically 2k2Ω.  
Rev. E | Page 6 of 40  
 
Data Sheet  
ADT7470  
FUNCTIONAL DESCRIPTION  
sensor (approximately 120 ms) and on the number of TMP05s  
daisy-chained together. The total monitoring cycle time is the  
temperature conversion time multiplied by the number of  
temperature channels being monitored.  
GENERAL DESCRIPTION  
The ADT7470 is a multichannel, pulse-width modulation  
(PWM) fan controller and monitor for any system requiring  
monitoring and cooling. The device communicates with the  
system via a serial system management bus. The device has  
a single address line for address selection (Pin 11), a serial  
data line for reading and writing addresses and data (Pin 16),  
and an input line for the serial clock (Pin 1). All control and  
programming functions of the ADT7470 are performed over  
the serial bus, which supports both SMBus and fast I2C speci-  
Fan tach measurements are taken in parallel and are not syn-  
chronized with the temperature measurements in any way  
CONFIGURATION REGISTER 1 (ADDRESS 0X40)  
This register contains the STRT bit, Bit 0, which begins the  
monitoring cycle on the ADT7470.  
The SMBus timeout can be disabled , fast tach enabled, and  
the registers locked, by writing to this register.  
SMBALERT  
fications. In addition, an  
interrupt output is  
provided to indicate out-of-limit conditions.  
Control of high or low frequency fan drive, and the config-  
uration for Pin 13, can be accessed via this register.  
When the ADT7470 monitoring sequence is started, it cycles  
through each fan tach input to measure fan speed. Measured  
values from these inputs are stored in value registers. These  
can be read out over the serial bus, or they can be automatically  
compared with programmed limits stored in the limit registers.  
The results of out-of-limit comparisons are stored in the status  
registers, which can be read over the serial bus to flag out-of-  
limit conditions. If fan speeds drop below preset levels or a  
fan stalls, an interrupt is generated. Likewise, the ADT7470  
can flag fan over speed conditions by using limits set in the  
fan tach maximum registers.  
See Table 31 for more details.  
CONFIGURATION REGISTER 2 (ADDRESS 0X74)  
Writing a 1 to Bit 0 in this register puts the ADT7470 in  
shutdown mode, which puts the part into a low current  
consumption mode.  
The PWM frequency for each fan is controlled via this register.  
Fan speed measurement can be disabled for each fan by writing  
to this register.  
ADT7470 Monitoring Cycle  
See Table 44 for more details.  
The monitoring cycle begins when a 1 is written to the start  
bit (Bit 0) of Configuration Register 1 (Register 0x40). Each  
fan tach input is monitored in turn, and, as each measurement  
is completed, the result is automatically stored in the appropri-  
ate value register. Multiple temperature channels can also be  
monitored by clocking in temperatures using the TMP_IN  
pin. The temperature measurement function is addressed  
in hardware and requires no software intervention. The  
monitoring cycle continues unless disabled by writing a 0  
to Bit 7 of Configuration Register 1.  
ID REGISTERS  
The ADT7470 has three read-only registers for identifying  
the part and silicon revision.  
The device ID register is located at address 0x3D, and is set  
to 0x70.  
The company ID register, located at address 0x3E, is set to 0x41.  
The revision number register is at address 0x3F, and contains  
the revision number of the ADT7470 silicon.  
The rate of temperature measurement updates depends on  
the nominal conversion rate of the TMP05/TMP06 temperature  
Rev. E | Page 7 of 40  
 
 
 
 
 
ADT7470  
Data Sheet  
GENERAL-PURPOSE I/O PINS (OPEN DRAIN)  
The ADT7470 has four pins that can be configured as either general-purpose logic pins or as PWM outputs. Each GPIO pin has a  
corresponding enable, direction, polarity and status bit.  
Pin  
Function  
Enable  
Register Address and Bit  
0x7F [3]  
GPIO1  
Direction  
Polarity  
Status  
0x80 [7]  
0x80 [6]  
0x81 [4]  
GPIO2  
GPIO3  
GPIO4  
Enable  
0x7F [2]  
0x80 [5]  
0x80 [4]  
0x81 [5]  
Direction  
Polarity  
Status  
Enable  
0x7F [1]  
0x80 [3]  
0x80 [2]  
0x81 [6]  
Direction  
Polarity  
Status  
Enable  
0x7F [0]  
Direction  
Polarity  
Status  
0x80 [1]  
0x80 [0]  
0x81 [7]  
To enable the PWM output on the ADT7470 as GPIOs, the enable bits in Register 0x7F must be set to 1.  
Setting a direction bit to 1 in the GPIO configuration register makes the corresponding GPIO pin an output. Clearing the direction bit to  
0 makes it an input.  
Setting a polarity bit to 1 makes the corresponding GPIO pin active high. Clearing the polarity bit to 0 makes it active low.  
When a GPIO pin is configured as an input, the corresponding bit in the GPIO status register is read-only and is set when the input is  
asserted. When a GPIO pin is configured as an output, the corresponding bit in one of the GPIO status registers becomes read/write.  
Setting this bit asserts the GPIO output. Note that whether a GPIO pin is configured as an input or as an output, asserted can be high or  
low, depending on the setting of the polarity bit.  
Rev. E | Page 8 of 40  
 
Data Sheet  
ADT7470  
SMBUS/I2C SERIAL INTERFACE  
16  
15  
14  
13  
12  
11  
10  
9
1
2
3
4
5
6
7
8
Control of the ADT7470 is carried out using the serial system  
management bus (SMBus). This interface is fully compatible  
with SMBus 2.0 electrical specifications and meets 400 pF bus  
capacitance requirements. The device also supports fast I2C  
(400 kHz max). The ADT7470 is connected to the bus as a slave  
device under the control of a master controller or service  
processor.  
ADT7470  
ADDR  
ADDRESS SELECTION  
Figure 6. SMBus Address = 0x5C or 0x2E (Pin 11 = Floating)  
The ADT7470 has a 7-bit serial bus address. When the device  
is powered up with Pin 11 (ADDR) high, the ADT7470 has an  
SMBus address of 010 1111 or 0x5E (left-justified). Because the  
address is 7 bits, it can be left- or right-justified; this determines  
whether the address reads as 0x5x or 0x2x. Pin 11 can be left  
floating or tied low for other addressing options, as shown in  
Table 5. See also Figure 4, Figure 5, and Figure 6.  
The device address is sampled and latched on the first valid  
SMBus transaction, so any additional attempted addressing  
changes have no immediate effect. The facility to make  
hardwired changes to the SMBus slave address allows the user  
to avoid conflicts with other devices sharing the same serial bus,  
for example, if more than one ADT7470 is used in a system.  
SERIAL BUS PROTOCOL  
Table 5. ADT7470 Address Select Mode  
Pin 11 (ADDR) State  
Address  
The serial bus protocol operates as follows:  
High (10 kΩ to VCC)  
010 1111 (0x5E left-justified or  
0x2F right-justified)  
010 1100 (0x58 left-justified or  
0x2C right-justified)  
010 1110 (0x5C left-justified or  
0x2E right-justified)  
1. The master initiates data transfer by establishing a start  
condition, defined as a high-to-low transition on the serial  
data line, SDA, while the serial clock line, SCL, remains  
high. This indicates that an address/data stream follows.  
All slave peripherals connected to the serial bus respond  
to the start condition, and shift in the next 8 bits, consist-  
Low (10 kΩ to GND)  
Floating (no pull-up)  
W
ing of a 7-bit address (MSB first) and an R/ bit. This  
determines the direction of the data transfer, that is,  
whether data is written to or read from the slave device.  
16  
15  
14  
1
2
3
4
5
6
7
8
The peripheral whose address corresponds to the transmit-  
ted address responds by pulling the data line low during  
the low period before the 9th clock pulse, known as the  
acknowledge bit. All other devices on the bus now remain  
idle while the selected device waits for data to be read from  
ADT7470  
V
CC  
13  
12  
11  
10  
9
10k  
TYP  
ADDR  
W
or written to it. If the R/ bit is 0, the master writes to the  
W
slave device. If the R/ bit is 1, the master reads from the  
slave device.  
Figure 4. SMBus Address = 0x5E or 0x2F (Pin 11 = 1)  
2. Data is sent over the serial bus in sequences of 9 clock pulses:  
8 bits of data followed by an acknowledge bit from the slave  
device. Transitions on the data line must occur during the  
low period of the clock signal and remain stable during the  
high period. This is because a low-to-high transition when  
the clock is high might be interpreted as a stop signal. The  
number of data bytes that can be transmitted over the serial  
bus in a single read or write operation is limited only by  
what the master and slave devices can handle.  
16  
1
15  
14  
13  
12  
11  
10  
9
2
3
4
5
6
7
8
ADT7470  
ADDR  
10k  
TYP  
3. After all data bytes are read or written, stop conditions  
are established. In write mode, the master pulls the data  
line high during the 10th clock pulse to assert a stop  
condition. In read mode, the master device overrides  
the acknowledge bit by pulling the data line high during  
the low period before the 9th clock pulse. This is known as  
No Acknowledge. The master then takes the data line low  
Figure 5. SMBus Address = 0x58 or 0x2C (Pin 11 = 0)  
Rev. E | Page 9 of 40  
 
 
 
 
 
 
 
ADT7470  
Data Sheet  
during the low period before the 10th clock pulse, then  
high during the 10th clock pulse to assert a stop condition.  
To write data to one of the device data registers or read data  
from it, the address pointer register must be set so that the  
correct data register is addressed. Then data can be written into  
that register or read from it. The first byte of a write operation  
always contains an address that is stored in the address pointer  
register. If data is to be written to the device, the write operation  
contains a second data byte that is written to the register selected  
by the address pointer register.  
Any number of bytes of data can be transferred over the serial  
bus in one operation. However, it is not possible to mix read  
and write in one operation, because the type of operation is  
determined at the beginning and subsequently cannot be  
changed without starting a new operation.  
In the ADT7470, write operations contain either one or two  
bytes, and read operations contain one byte and perform the  
This is illustrated in Figure 7. The device address is sent over the  
W
bus followed by R/ set to 0. This is followed by two data bytes.  
following functions.  
1
9
1
9
SCL  
0
1
0
1
1
A1  
A0  
R/W  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
SDA  
START BY  
ACK. BY  
ADT7470  
ACK. BY  
ADT7470  
MASTER  
FRAME 1  
FRAME 2  
SERIAL BUS ADDRESS  
BYTE  
ADDRESS POINTER REGISTER BYTE  
1
9
SCL (CONTINUED)  
SDA (CONTINUED)  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
ACK. BY STOP BY  
ADT7470 MASTER  
FRAME 3  
DATA  
BYTE  
Figure 7. Writing a Register Address to the Address Pointer Register, Then Writing Data to the Selected Register  
1
0
9
1
9
SCL  
SDA  
1
0
1
1
A1  
A0  
R/W  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
START BY  
MASTER  
ACK. BY  
ADT7470  
ACK. BY STOP BY  
ADT7470 MASTER  
FRAME 1  
FRAME 2  
SERIAL BUS ADDRESS  
BYTE  
ADDRESS POINTER REGISTER BYTE  
Figure 8. Writing to the Address Pointer Register Only  
1
9
1
9
SCL  
0
1
0
1
1
A1  
A0  
R/W  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
SDA  
START BY  
MASTER  
ACK. BY  
ADT7470  
NO ACK.  
BY MASTER MASTER  
STOP BY  
FRAME 1  
FRAME 2  
SERIAL BUS ADDRESS  
BYTE  
DATA BYTE FROM  
ADT7470  
Figure 9. Reading Data from a Previously Selected Register  
Rev. E | Page 10 of 40  
 
 
 
Data Sheet  
ADT7470  
The first data byte is the address of the internal data register  
to be written to, which is stored in the address pointer register.  
The second data byte is the data to be written to the internal  
data register.  
Send Byte  
In this protocol, the master device sends a single command byte  
to a slave device, as follows:  
1. The master device asserts a start condition on SDA.  
How data is read from a register depends on whether or not  
the address pointer register value is known.  
2. The master sends the 7-bit slave address followed by  
the write bit (low).  
If the ADT7470 address pointer register value is unknown or  
not the desired value, it is first necessary to set it to the correct  
value before data can be read from the desired data register.  
This is done by performing a write to the ADT7470 as before,  
but only the data byte containing the register address is sent,  
because data cannot be written to the register. This is shown  
in Figure 8.  
3. The addressed slave device asserts ACK on SDA.  
4. The master sends a command code.  
5. The slave asserts ACK on SDA.  
6. The master asserts a stop condition on SDA,  
and the transaction ends.  
For the ADT7470, the send byte protocol is used to write a  
register address to RAM for a subsequent single byte read  
from the same address. This is shown in Figure 10.  
A read operation is then performed consisting of the serial bus  
W
address, R/ bit set to 1, followed by the data byte read from  
the data register. This is shown in Figure 9.  
1
2
3
4
5
6
If the address pointer register is known to be already at the  
desired address, data can be read from the corresponding data  
register without first writing to the address pointer register,  
so the operation shown in Figure 8 can be omitted.  
SLAVE  
ADDRESS  
REGISTER  
ADDRESS  
S
W
A
A
P
Figure 10. Setting a Register Address for Subsequent Read  
Note the following:  
If it is required to read data from the register immediately after  
setting up the address, the master can assert a repeat start con-  
dition immediately after the final ACK and carry out a single-  
byte read without asserting an intermediate stop condition.  
Although it is possible to read a data byte from a data  
register without first writing to the address pointer register  
if the address pointer register is already at the correct value,  
it is not possible to write data to a register without writing  
to the address pointer register. This is because the first data  
byte of a write is always written to the address pointer  
register.  
Write Byte  
In this operation, the master device sends a command byte and  
one data byte to the slave device, as follows:  
1. The master device asserts a start condition on SDA.  
In Figure 7 to Figure 9, the serial bus address is shown as  
the default value 01011(A1)(A0), where A1 and A0 are set  
by the address select mode function previously defined.  
2. The master sends the 7-bit slave address followed by the  
write bit (low).  
3. The addressed slave device asserts ACK on SDA.  
4. The master sends a command code.  
5. The slave asserts ACK on SDA.  
In addition to supporting the send byte and receive byte  
protocols, the ADT7470 also supports the read byte  
protocol. See System Management Bus Specifications  
Rev. 2.0 for more information.  
6. The master sends a data byte.  
If it is required to perform several read or write operations  
in succession, the master can send a repeat start condition  
instead of a stop condition to begin a new operation.  
7. The slave asserts ACK on SDA.  
8. The master asserts a stop condition on SDA to end  
the transaction.  
WRITE OPERATIONS  
This is shown in Figure 11.  
The SMBus specification defines several protocols for different  
types of read and write operations. The protocols used in the  
ADT7470 are discussed in the following sections. The following  
abbreviations are used in the diagrams:  
1
2
3
4
5
6
7
8
SLAVE  
ADDRESS  
REGISTER  
ADDRESS  
S
W
A
A
DATA  
A
P
S—Start  
P—Stop  
Figure 11. Single-Byte Write to a Register  
R—Read  
W—Write  
A—Acknowledge  
A
—No Acknowledge  
The ADT7470 uses the following SMBus write protocols.  
Rev. E | Page 11 of 40  
 
 
 
ADT7470  
Data Sheet  
2. The master initiates a read operation and sends the alert  
response address (ARA = 000 1100). This is a general call  
address that must not be used as a specific device address.  
READ OPERATIONS  
The ADT7470 uses the following SMBus read protocols.  
Receive Byte  
SMBALERT  
3. The device whose  
output is low responds to  
This is useful when repeatedly reading a single register.  
The register address must be set up previously. In this  
operation, the master device receives a single byte from  
a slave device, as follows:  
the alert response address, and the master reads its device  
address. The address of the device is now known, and it  
can be interrogated in the usual way.  
SMBALERT  
4. If more than one device’s  
output is low,  
1. The master device asserts a start condition on SDA.  
the one with the lowest device address has priority,  
in accordance with normal SMBus arbitration.  
2. The master sends the 7-bit slave address followed by  
the read bit (high).  
5. Once the ADT7470 responds to the alert response  
address, the master must read the status registers,  
3. The addressed slave device asserts ACK on SDA.  
4. The master receives a data byte.  
SMBALERT  
and the  
is gone.  
is cleared only if the error condition  
5. The master asserts NO ACK on SDA.  
SMBus TIMEOUT  
6. The master asserts a stop condition on SDA  
and the transaction ends.  
The ADT7470 includes an SMBus timeout feature. If there is no  
SMBus activity for more than 31 ms, the ADT7470 assumes that  
the bus is locked and releases the bus. This prevents the device  
from locking or holding the SMBus expecting data. Some SMBus  
controllers cannot handle the SMBus timeout feature, so it can  
be disabled.  
In the ADT7470, the receive byte protocol is used to read a  
single byte of data from a register whose address was previously  
set by a send byte or write byte operation.  
1
2
3
4
5
6
SLAVE  
ADDRESS  
S
R
A
DATA  
A
P
Table 6. Configuration Register 1—Register 0x40  
Bit Address and Value  
Description  
Figure 12. Single-Byte Write from a Register  
Bit 3 TODIS = 0  
Bit 3 TODIS = 1  
SMBus timeout enabled (default).  
SMBus timeout disabled.  
Alert Response Address  
Alert response address (ARA) is a feature of SMBus devices,  
which allows an interrupting device to identify itself to the host  
when multiple devices exist on the same bus.  
Although the ADT7470 supports packet error checking (PEC),  
its use is optional. It is triggered by supplying the extra clock  
for the PEC byte. The PEC byte is calculated using CRC-8.  
The frame check sequence (FCS) conforms to CRC-8 by the  
following polynomial:  
SMBALERT  
The  
or can be used as an  
connected to a common  
output can be used as an interrupt output  
SMBALERT  
. One or more outputs can be  
C(x) = x8 + x2 + x1 + 1  
SMBALERT  
line connected to the  
SMBALERT  
master. If a device’s  
occurs:  
line goes low, the following  
Consult the SMBus 1.1 Specification for more information by  
searching online.  
SMBALERT  
1.  
is pulled low.  
Rev. E | Page 12 of 40  
 
 
 
Data Sheet  
ADT7470  
TEMPERATURE MEASUREMENT USING TMP05/TMP06  
Table 7. Temperature Reading Registers  
MEASURING TEMPERATURE  
Register  
0x20  
0x21  
0x22  
0x23  
0x24  
0x25  
0x26  
0x27  
0x28  
0x29  
0x78  
Reading  
Default  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
The ADT7470 can be connected with up to 10 daisy-chained  
TMP05/TMP06 devices for temperature measurement. Each  
TMP05/TMP06 performs an ambient temperature measure-  
ment, and outputs a PWM signal. The ADT7470 decodes the  
PWM into a temperature measurement, and stores the result  
in the temperature reading registers, listed in Table 7.The  
maximum temperature read back from all TMP05 temperature  
readings is stored in register 0x78.  
Temperature 1 reading  
Temperature 2 reading  
Temperature 3 reading  
Temperature 4 reading  
Temperature 5 reading  
Temperature 6 reading  
Temperature 7 reading  
Temperature 8 reading  
Temperature 9 reading  
Temperature 10 reading  
Max TMP05 temperature  
To use the ADT7470 with TMP05/TMP06, the parts should be  
connected as shown in Figure 13. Pin 13 on the ADT7470  
should be configured as TMP_START, by setting Configuration  
Register 1 Bit 7 to Bit 1. (Register address 0x40 Bit[7] =1). The  
start pulse required by the TMP05/06 will be output on the  
TMP_START pin. The OUT pin on the last TMP05/06 in the  
daisy-chain should be connected to Pin 12 on the ADT7470,  
TMP_IN. For more information on the TMP05/06, refer to the  
TMP05/TMP06 data sheet.  
TMP05/TMP06 Decoder  
The ADT7470 includes a PWM processing engine to decode the  
daisy-chained PWM output from multiple TMP05s and TMP06s.  
It then passes each decoded temperature value to the temper-  
ature value registers. This allows the ADT7470 to do high/  
low limit comparisons of temperature and to automatically  
control fan speed based on measured temperature. The PWM  
processing engine contains all necessary logic to initiate start  
conversions on the first daisy-chained TMP05/TMP06 and  
to synchronize with each temperature value as it is fed back to  
the device through the daisy chain. The start function is multi-  
plexed onto the same pin that can be used to blast the fans  
to full speed. The start conversion for TMP05/TMP06 temp-  
erature measurement is fully transparent to the user and does  
not require any software intervention to function.  
Reporting of 8-bit temperature values occurs only if the  
TMP_IN function is used and if TMP05/TMP06s are daisy-  
chained according to their data sheet and connected as shown.  
The ADT7470 does not have any temperature measurement  
capability when used as a standalone device without TMP05s  
and TMP06s connected.  
16  
15  
14  
13  
12  
11  
10  
9
SCL  
1
2
3
4
5
6
7
8
SDA  
GND  
PWM1  
V
ADT7470  
SMBALERT  
CC  
FULL_SPEED/TMP_START  
CONV/IN  
TMP05/  
TACH3  
PWM2  
TACH1  
TACH2  
PWM3  
TMP_IN  
TMP06  
NO. 1  
ADDR  
PWM4  
TACH4  
OUT  
CONV/IN  
TMP05/  
TMP06  
NO. 2  
OUT  
CONV/IN  
TMP05/  
TMP06  
NO. 3  
OUT  
CONV/IN  
TMP05/  
TMP06  
NO. n  
OUT  
Figure 13. Interfacing the ADT7470 to Multiple Daisy-Chained TMP05/TMP06 Temperature Sensors  
Rev. E | Page 13 of 40  
 
 
 
 
ADT7470  
Data Sheet  
Example:  
TEMPERATURE READBACK BY THE HOST  
1. Temperature read back from register 0x20: 0xFF.  
2. Convert into decimal format. 0xFF = 255 (decimal).  
The user cannot read the ADT7470 temperature register values  
if the ADT7470 is in the process of a temperature measurement.  
The user must wait until the data from all the TMP05s and  
TMP06s in the chain are received by the ADT7470 before  
reading these values. Otherwise, the temperature registers  
may store an incorrect value. It is recommended to wait at  
least 200 ms for each TMP05 and TMP06 in the chain. The  
recommended procedure is as follows:  
3. Check if MSB is set to 1. It is in this example. Therefore,  
use negative temperature formula, ADC (d) minus 256.  
4. Temperature = 255 − 256 = −1°C.  
Table 8. Temperature Data Format  
Temperature (°C)  
Digital Output (8 Bit)  
1000 0000  
1000 0011  
1001 1100  
1011 0101  
1100 1110  
1110 0111  
1111 0110  
0000 0000  
0000 1010  
0001 1001  
0011 0010  
0100 1011  
0110 0100  
0111 1101  
0111 1111  
1. Set Register 40 Bit[7] = 1. This starts the temperature  
measurements.  
−128  
−125  
−100  
−75  
−50  
−25  
−10  
+0  
+10  
+25  
+50  
+75  
+100  
+125  
+175  
2. Wait 200 ms for each TMP05/TMP06 in the loop.  
3. Set Register 40 Bit[7] = 0.  
4. Read the temperature registers.  
TEMPERATURE DATA FORMAT  
Temperature data on the ADT7470 is stored in an 8-bit format,  
with the 7 LSBs being the temperature, and the MSB acting as  
the sign bit. Use the following formulae when reading back  
from the temperature registers, o calculate the temperature:  
Positive Temperature = ADC Code (decimal)  
Negative Temperature = ADC (decimal) minus 256  
For negative temperature readings, the MSB is always set to 1.  
tSTART  
ADT7470  
t1 STOP  
t2 STOP  
TMP_START  
t1 HIGH  
t1 LOW  
76ms  
t2 HIGH  
40ms  
t2 LOW  
40ms  
100ms  
t1  
t2  
ADT7470  
TMP05 1  
TEMP = 25°C  
TMP05 2  
TEMP = 120°C  
TMP_IN  
NOTES:  
tSTART IS GENERATED BY THE ADT7470 AND IS THE START PULSE FOR TMP05 1.  
t1 STOP IS GENERATED BY TMP05 1 AND IS THE START PULSE FOR TMP05 2.  
t2 STOP IS GENERATED BY TMP05 2.  
EACH START/STOP PULSE IS TYPICALLY 25µs.  
TMP05s MUST BE IN DAISY-CHAIN MODE.  
SEE THE TMP05 DATA SHEET FOR MORE INFORMATION.  
Figure 14. Typical Timing Diagram of ADT7470 with Two TMP05s Connected in Daisy-Chain Mode  
Rev. E | Page 14 of 40  
 
 
Data Sheet  
ADT7470  
TEMPERATURE MEASUREMENT LIMITS  
THERMAL ZONES FOR AUTOMATIC FAN CONTROL  
High and low temperature limits can be individually set for  
each of the TMP05/06s that the ADT7470 is monitoring. The  
temperature limit registers are at address 0x44 to 0x57. The  
power-on default value for all TMP05/06 lower limits is −127°C  
(0x81). The power –on default value for all TMP05/06 upper  
limits is +127°C (0x7F). See Table 9 for details on the  
temperature limit registers.  
The ADT7470 can control up to four independent thermal zones  
with individual fans. The user can configure which TMP05  
controls which fan via register 0x7C and 0x7D.For each of the four  
thermal zones, an individual TMP05, or the hottest TMP05 in the  
daisy chain, can control the fan. In a system with n TMP05s, it is  
possible to have 1 or n TMP05s controlling each fan.  
Thermal Zone TMIN  
If the temperature measured from a TMP05/06 exceeds the  
upper or lower limit, then a status bit in the Interrupt Status  
registers will be set to 1. See Table 12 and Table 13 for more  
details on the temperature status bits.  
For each of the four thermal zones, the user can configure the  
minimum temperature at which the fans run. Registers 0x6E to  
0x71 should be configured with the minimum temperature for  
each thermal zone. When the temperature exceeds TMIN for that  
thermal zone, the fans run at minimum speed (PWMMIN). The  
SMBALERT  
will assert is any temperature exceeds either the  
upper or lower limits. The temperature measurements can be  
SMBALERT  
fan speed increases to maximum speed (PWMMAX) at [TMIN  
+
20°C]. Fan on/off hysteresis is set at 4°C so that the fans turn off  
4°C below the temperature at which they turn on. This prevents  
fan chatter in the system.  
masked as interrupt sources for  
using the interrupt  
mask registers, 0x72 and 0x73. See Table 14 and Table 15 for  
more details on the interrupt mask registers.  
Rev. E | Page 15 of 40  
 
 
ADT7470  
Data Sheet  
LIMIT AND STATUS REGISTERS  
LIMIT VALUES  
Table 10. Fan Underspeed Limit Registers  
Register Address  
Description  
Default  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
Associated with each measurement channel on the ADT7470  
are high and low limits. These can form the basis of system  
status monitoring; a status bit can be set for any out-of-limit  
condition and be detected by polling the device. Alternatively,  
0x58  
0x59  
0x5A  
0x5B  
0x5C  
0x5D  
0x5E  
0x5F  
Tach 1 Min Low Byte  
Tach 1 Min High Byte  
Tach 2 Min Low Byte  
Tach 2 Min High Byte  
Tach 3 Min Low Byte  
Tach 3 Min High Byte  
Tach 4 Min Low Byte  
Tach 4 Min High Byte  
SMBALERT  
interrupts can be generated to automatically flag  
a service processor or microcontroller for out-of-limit  
conditions as they occur.  
TEMPERATURE LIMITS  
Table 9 lists the 8-bit temperature limits on the ADT7470.  
Table 11. Fan Overspeed Limit Registers  
Table 9. Temperature Limit Registers (8-Bit Limits)  
Register Address  
Description  
Default  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
Register Address  
Description  
Default  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x60  
0x61  
0x62  
0x63  
0x64  
0x65  
0x66  
0x67  
Tach 1 Max Low Byte  
Tach 1 Max High Byte  
Tach 2 Max Low Byte  
Tach 2 Max High Byte  
Tach 3 Max Low Byte  
Tach 3 Max High Byte  
Tach 4 Max Low Byte  
Tach 4 Max High Byte  
0x44  
0x45  
0x46  
0x47  
0x48  
0x49  
0x4A  
0x4B  
0x4C  
0x4D  
0x4E  
0x4F  
0x50  
0x51  
0x52  
0x53  
0x54  
0x55  
Temperature 1 Low Limit  
Temperature 1 High Limit  
Temperature 2 Low Limit  
Temperature 2 High Limit  
Temperature 3 Low Limit  
Temperature 3 High Limit  
Temperature 4 Low Limit  
Temperature 4 High Limit  
Temperature 5 Low Limit  
Temperature 5 High Limit  
Temperature 6 Low Limit  
Temperature 6 High Limit  
Temperature 7 Low Limit  
Temperature 7 High Limit  
Temperature 8 Low Limit  
Temperature 8 High Limit  
Temperature 9 Low Limit  
Temperature 9 High Limit  
Temperature 10 Low Limit  
Temperature 10 High Limit  
OUT-OF-LIMIT COMPARISONS  
Once all limits are programmed, the ADT7470 can be enabled  
to begin monitoring. The ADT7470 measures all parameters in  
round-robin format and sets the appropriate status bit for out-  
of-limit conditions.  
Comparisons are done differently depending on whether the  
measured value is compared to a high limit or a low limit.  
High Limit: > Comparison Performed  
Low Limit: ≤ Comparison Performed  
0x56  
0x57  
FAN SPEED LIMITS  
The fan tach measurements are 16-bit results. The fan tach  
limits are also 16 bits, consisting of two bytes: a high byte and  
low byte. On the ADT7470 it is possible to set both high and  
low speed fan limits for over speed and under speed or stall con-  
ditions. Be aware that, because the fan tach period is actually  
being measured, exceeding the limit by 1 indicates a slow or  
stalled fan. Likewise, exceeding the high speed limit by 1  
generates an over speed condition.  
Rev. E | Page 16 of 40  
 
 
 
 
 
 
Data Sheet  
ADT7470  
Interrupt status mask registers (Register 0x72 and Register 0x73)  
allow individual interrupt sources to be masked from causing an  
STATUS REGISTERS  
The results of limit comparisons are stored in Status Register 1  
and Status Register 2. The status register bit for each channel  
reflects the status of the last measurement and limit comparison  
on that channel. If a measurement is within limits, the corre-  
sponding status register bit is cleared to 0. If the measurement  
is out of limit, the corresponding status register bit is set to 1.  
SMBALERT  
. However, if one of these masked interrupt sources  
goes out of limit, its associated status bit is still set in the interrupt  
status registers. This allows the device to be periodically polled to  
determine if an error condition has subsided, without unnecessarily  
tying up precious system resources handling interrupt service  
routines. The issue is that the device could potentially interrupt the  
system every monitoring cycle (< 1 sec) as long as a measurement  
parameter remains out of limit. Masking eliminates unwanted  
system interrupts.  
The state of the various measurement channels can be polled  
by reading the status registers over the serial bus. When Bit 7  
(OOL) of Status Register 1 (Register 0x41) is a 1, an out-of-limit  
event has been flagged in Status Register 2. This means that  
Status Register 2 must be read only when the OOL bit is set.  
The OOL bit (Register 0x41 Bit[7]), and the NORM bit  
SMBALERT  
(Register 0x42 Bit[3]) do not activate  
.
Reading the status registers clears the appropriate status bit as  
long as the error condition that caused the interrupt has cleared.  
Status register bits are sticky. Whenever a status bit is set,  
indicating an out-of-limit condition, it remains set even if the  
event that caused it has gone away (until read). The only way to  
clear the status bit is to read the status register when the event has  
gone away.  
Table 12. Interrupt Status Register 1 (Register 0x41)  
Bit No.  
Mnemonic  
OOL  
R7T  
R6T  
R5T  
R4T  
R3T  
R2T  
R1T  
Description  
7
6
5
4
3
2
1
0
A 1 denotes that a bit in Status Register 2 is set and Status Register 2 should now be read.  
A 1 indicates that TMP05 Temperature 7 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 6 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 5 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 4 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 3 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 2 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 1 high or low limit has been exceeded.  
Table 13. Interrupt Status Register 2 (Register 0x42)  
Bit No.  
Mnemonic  
Fan 4  
Fan 3  
Fan 2  
Fan 1  
NORM  
R10T  
Description  
7
6
5
4
3
2
1
0
A 1 indicates that Fan 4 has dropped below minimum speed or is above maximum speed.  
A 1 indicates that Fan 3 has dropped below minimum speed or is above maximum speed.  
A 1 indicates that Fan 2 has dropped below minimum speed or is above maximum speed.  
A 1 indicates that Fan 1 has dropped below minimum speed or is above maximum speed.  
A 1 indicates that the temperatures are below TMIN and that the fans are supposed to be off.  
A 1 indicates that TMP05 Temperature 10 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 9 high or low limit has been exceeded.  
A 1 indicates that TMP05 Temperature 8 high or low limit has been exceeded.  
R9T  
R8T  
Rev. E | Page 17 of 40  
 
 
 
ADT7470  
Data Sheet  
SMBALERT  
Handling  
To prevent the system from being tied up servicing interrupts,  
SMBALERT  
Interrupts  
SMBALERT INTERRUPT  
SMBALERT  
The ADT7470 can be polled for status, or an  
handle the  
1. Detect the  
interrupt as follows:  
SMBALERT  
interrupt can be generated for out-of-limit conditions. Note  
SMBALERT  
how the  
writing interrupt handler software.  
SMBALERT  
output and status bits behave when  
assertion.  
2. Enter the interrupt handler.  
Figure 15 shows how the  
output and sticky status  
3. Read the status registers to identify the interrupt source.  
bits behave. Once a limit is exceeded, the corresponding status  
bit is set to 1. The status bit remains set until the error condition  
subsides the status register is read. The status bits are referred  
to as sticky because they remain set until read by software. This  
ensures that an out-of-limit event cannot be missed if software  
4. Mask the interrupt source by setting the appropriate mask  
bit in the interrupt mask registers (Register 0x72 and  
Register 0x73).  
5. Take the appropriate action for a given interrupt source.  
6. Exit the interrupt handler.  
SMBALERT  
is polling the device periodically. The  
output  
remains low for the duration that a reading is out of limit until  
the status register is read. This has implications for how  
software handles the interrupt.  
7. Periodically poll the status registers. If the interrupt status  
bit is cleared, reset the corresponding interrupt mask bit  
SMBALERT  
to 0. This causes the  
output and status bits  
to behave as shown in Figure 16.  
HIGH LIMIT  
TEMPERATURE  
CLEARED ON READ  
(TEMP BELOW LIMIT)  
"STICKY"  
STATUS  
BIT  
TEMP BACK IN LIMIT  
(STATUS BIT STAYS SET)  
SMBALERT  
SMBALERT  
Figure 15.  
and Status Bit Behavior  
HIGH LIMIT  
TEMPERATURE  
CLEARED ON READ  
(TEMP BELOW LIMIT)  
"STICKY"  
STATUS  
BIT  
TEMP BACK IN LIMIT  
(STATUS BIT STAYS SET)  
SMBALERT  
INTERRUPT  
MASK BIT SET  
INTERRUPT MASK BIT  
CLEARED  
(SMBALERT RE-ENABLED)  
SMBALERT  
Figure 16. How Masking the Interrupt Source Affects  
Output  
Rev. E | Page 18 of 40  
 
 
 
Data Sheet  
ADT7470  
SMBALERT  
Enabling the  
Interrupt Output  
Masking Interrupt Sources  
SMBALERT  
The  
interrupt output is a dedicated function pro-  
Interrupt Mask Register 1 and Interrupt Mask Register 2 are  
located at Address 0x72 and Address 0x73. These allow indi-  
vidual interrupt sources to be masked out to prevent unwanted  
vided on Pin 14 to signal out-of-limit conditions to a host or  
system processor. Because this is a dedicated function, it is  
important that limit registers be programmed before monitoring  
is enabled to prevent spurious interrupts from occurring on the  
SMBALERT  
interrupts. Masking an interrupt source prevents  
SMBALERT  
only the  
output from being asserted; the appro-  
SMBALERT  
SMBALERT  
pin. Although the  
specifically disabled, interrupt sources can be masked to prevent  
SMBALERT  
output cannot be  
priate status bit is still set as usual. This is useful if the system  
polls the monitoring devices periodically to determine whether  
or not out-of-limit conditions have subsided, without tying up  
time-critical system resources.  
assertions. Monitoring is enabled when Bit 0 (STRT)  
of Configuration Register 1 (Register 0x40) is set to 1.  
Table 14. Interrupt Mask Register 1 (Register 0x72)  
Bit No.  
Mnemonic  
Unused  
R7T  
Description  
7
6
5
4
3
2
1
0
Unused.  
A 1 masks the SMBALERT for TMP05 Temperature 7.  
A 1 masks the SMBALERT for TMP05 Temperature 6.  
A 1 masks the SMBALERT for TMP05 Temperature 5.  
A 1 masks the SMBALERT for TMP05 Temperature 4.  
A 1 masks the SMBALERT for TMP05 Temperature 3.  
A 1 masks the SMBALERT for TMP05 Temperature 2.  
A 1 masks the SMBALERT for TMP05 Temperature 1.  
R6T  
R5T  
R4T  
R3T  
R2T  
R1T  
Table 15. Interrupt Mask Register 2 (Register 0x73)  
Bit No.  
Mnemonic  
Fan 4  
Fan 3  
Fan 2  
Fan 1  
Unused  
R10T  
Description  
7
6
5
4
3
2
1
0
A 1 masks the SMBALERT for Fan 4 overspeed/underspeed conditions.  
A 1 masks the SMBALERT for Fan 3 overspeed/underspeed conditions.  
A 1 masks the SMBALERT for Fan 2 overspeed/underspeed conditions.  
A 1 masks the SMBALERT for Fan 1 overspeed/underspeed conditions.  
Unused.  
A 1 masks the SMBALERT for TMP05 Temperature 10.  
A 1 masks the SMBALERT for TMP05 Temperature 9.  
A 1 masks the SMBALERT for TMP05 Temperature 8.  
R9T  
R8T  
Rev. E | Page 19 of 40  
 
 
ADT7470  
Data Sheet  
FAN DRIVE USING PWM CONTROL  
LOW FREQUENCY FAN DRIVE  
The ADT7470 uses pulse-width modulation (PWM) to control  
fan speed. This relies on varying the duty cycle (or on/off ratio)  
of a square wave applied to the fan to vary the fan speed. Two  
main control schemes are used: low frequency and high fre-  
quency PWM.  
For low frequency, low-side drive, the external circuitry required  
to drive a fan using PWM control is extremely simple. A single  
NMOS FET is the only drive device required. The specifications  
of the MOSFET depend on the maximum current required by  
the fan being driven. Typical notebook fans draw a nominal  
170 mA; therefore, SOT devices can be used where board space  
is a concern. In desktops, fans can typically draw 250 mA to  
300 mA each. If the user needs to drive several fans in parallel  
from a single PWM output or drive larger server fans, the  
MOSFET needs to handle the higher current requirements. The  
only other stipulation is that the MOSFET should have a gate  
voltage drive, VGS, less than 3.3 V, for direct interfacing to the  
PWM pin of the ADT7470. VGS of the chosen MOSFET can be  
greater than 3.3 V as long as the pull-up on its gate is tied to 5 V.  
Configuration Register 1 Bit[6], at address 0x40, configures the  
fan drive for high or low frequency operation. If this bit is set to  
0, which is the default, high frequency fan drive is selected. If  
this bit is set to 1, low frequency fan drive is selected. All four  
PWM outputs on the ADT7470 have the same drive frequency.  
HIGH FREQUENCY FAN DRIVE  
One of the important features of fan controllers is the PWM  
drive frequency. Most fans are driven asynchronously at low  
frequency (30 Hz to 100 Hz). Increasingly, the devices drive  
fans at greater than 20 kHz. These controllers are meant to drive  
4-wire fans with PWM control built-in internal to the fan in  
Figure 17. The ADT7470 supports high frequency PWM (great  
than 20 kHz), as well as 1.4 kHz and other low frequency PWM.  
This allows the user to drive 3-wire or 4-wire fans.  
The MOSFET should also have a low on resistance to ensure  
that there is not significant voltage drop across the FET. This  
would reduce the voltage applied across the fan and, therefore,  
the maximum operating speed of the fan.  
Figure 18 shows how a 3-wire fan can be driven using low  
frequency PWM control where the control method is low-side,  
low frequency switching.  
If using 3-wire fans this mode, care should be taken to ensure  
that incomplete tach information does not occur at low PWM  
duty cycles, or short PWM pulse widths.  
Figure 18 shows the ideal interface when interfacing a tach  
signal from a 12 V fan (or greater voltage) to a 5 V (or less)  
logic device. In all cases, the tach signal from the fan must be  
kept below 5 V maximum to prevent damage to the ADT7470.  
The three resistors in Figure 18 ensure that the tach voltage  
is kept within safe levels for typical desktop and notebook  
systems.  
12V  
V
10k  
10kΩ  
1N4148  
TACH  
TACH  
4.7kΩ  
3.3V  
12V  
12V  
GND  
ADT7470  
10k  
10kΩ  
12V  
TACH/AIN  
1N4148  
PWM_IN  
FAN  
10kΩ  
TACH  
PWM  
4.7kΩ  
3.3V  
ADT7470  
10kΩ  
Figure 17. Driving a 4-Wire Fan  
Q1  
NDT3055L  
PWM  
Figure 18. Driving a 3-Wire Fan Using an N-Channel MOSFET  
Rev. E | Page 20 of 40  
 
 
 
 
 
Data Sheet  
ADT7470  
Figure 19 shows a fan drive circuit using an NPN transistor  
such as a general-purpose MMBT2222. While these devices  
are inexpensive, they tend to have much lower current handling  
capabilities and higher on resistance than MOSFETs. When  
choosing a transistor, care should be taken to ensure that it  
meets the fan’s current requirements. This is the only major  
difference between a MOSFET and NPN transistor fan driver  
circuit.  
Table 16. Fan Drive Frequency  
Register  
High Frequency Drive Low Frequency Drive  
0x74[6:4]  
(0x40[6] = 0)  
(0x40[6] = 1)  
000  
001  
010  
011  
100  
101  
110  
111  
1.4 kHz  
11 Hz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
14.7 Hz  
22.1 Hz  
29.4 Hz  
35.3 Hz  
44.1 Hz  
58.8 Hz  
88.2 Hz  
When using transistors, ensure that the base resistor is  
chosen such that the transistor is fully saturated when the fan  
is powered on. Otherwise, there are power inefficiencies in the  
implementation.  
INVERTED PWM OUTPUT  
12V  
12V  
The PWM duty cycle can be inverted by writing to the PWM  
Configuration registers. If the PWM duty cycle is inverted, then  
a PWM duty cycle setting of 33% results in an output duty cycle  
of 66%, as the PWM waveform is inverted.  
10kΩ  
12V  
FAN  
1N4148  
TACH/AIN  
10kΩ  
TACH  
4.7kΩ  
3.3V  
Table 17. PWM1/PWM2 Configuration (Register 0x68)  
Bit No.  
Mnemonic Description  
ADT7470  
5
INV1  
0 = PWM1 duty cycle not inverted  
470Ω  
(default).  
1 = PWM1 duty cycle inverted.  
0 = PWM2 duty cycle not inverted  
(default).  
Q1  
MMBT2222  
PWM  
4
INV2  
1 = PWM2 duty cycle inverted.  
Figure 19. Driving a 3-Wire Fan Using an NPN Transistor  
Low Frequency  
Table 18. PWM3/PWM4 Configuration (Register 0x69)  
Bit No.  
Mnemonic Description  
SETTING THE FAN DRIVE FREQUENCY  
5
INV3  
0 = PWM3 duty cycle not inverted  
Configuration Register 2 Bits[6:4] configure the fan drive  
frequency in both high and low frequency drive mode.  
(default).  
1 = PWM3 duty cycle inverted.  
4
INV4  
0 = PWM4 duty cycle not inverted  
(default).  
1 = PWM4 duty cycle inverted.  
FAN FULL SPEED FUNCTION  
When Pin 13 is configured for full speed operation, pulling the  
pin low will cause all fans to run at the maximum PWM duty  
cycle. A Logic 1 is output on the PWM pins in this case.  
Rev. E | Page 21 of 40  
 
 
 
 
ADT7470  
Data Sheet  
FAN SPEED MEASUREMENT  
R1 and R2 should be chosen such that  
TACH INPUTS  
2 V < VPULL-UP × R2/(RPULL-UP + R1 + R2) < 5 V  
Pin 6, Pin 7, Pin 4, and Pin 9 are open-drain tach inputs  
intended for fan speed measurement.  
The fan inputs have an input resistance of nominally 160 kΩ to  
ground, which should be taken into account when calculating  
resistor values.  
Signal conditioning in the ADT7470 accommodates the slow  
rise and fall times typical of fan tachometer outputs. The maxi-  
mum input signal range is 0 V to 5 V, even where VCC is less  
than 5 V. If these inputs are supplied from fan outputs that  
exceed 0 V to 5 V, either resistive attenuation of the fan signal  
or diode clamping must be included to keep inputs within an  
acceptable range. Figure 20 to Figure 23 show circuits for most  
common fan tach outputs.  
With a pull-up voltage of 12 V and pull-up resistor less than  
1 kΩ, suitable values for R1 and R2 are 100 kΩ and 47 kΩ.  
This gives a high input voltage of 3.83 V.  
V
12V  
CC  
ADT7470  
TACH  
O/P  
If the fan tach output has a resistive pull-up to VCC, it can be  
connected directly to the fan input, as shown in Figure 20.  
TACH  
FAN SPEED  
COUNTER  
PULLUP  
TYP. <1k  
OR TOTEM-POLE  
R1  
10k  
ZD1  
ZENER*  
12V  
V
CC  
*CHOOSE ZD1 VOLTAGE APPROX. 0.8 V  
CC  
PULLUP  
4.7k  
TYP  
ADT7470  
Figure 22. Fan with Strong Tach.  
Pull-Up to > VCC or Totem-Pole Output, Clamped with Zener and Resistor.  
TACH  
FAN SPEED  
COUNTER  
TACH  
OUTPUT  
V
12V  
CC  
Figure 20. Fan with Tach Pull-Up to VCC  
ADT7470  
<1k  
If the fan output has a resistive pull-up to 12 V (or other voltage  
greater than 5 V), the fan output can be clamped with a Zener  
diode, as shown in Figure 21. The Zener diode voltage should  
be chosen so that it is greater than VIH of the tach input but less  
than 5 V, allowing for the voltage tolerance of the Zener. A value  
of between 3 V and 5 V is suitable.  
R1*  
TACH  
FAN SPEED  
COUNTER  
TACH  
OUTPUT  
R2*  
*SEE TEXT  
Figure 23. Fan with Strong Tach.  
Pull-Up to > VCC or Totem-Pole Output, Attenuated with R1/R2.  
V
12V  
CC  
Pulse Stretching  
Pulse stretching of the PWM output is performed automatically  
in low frequency fan drive mode, to ensure that sufficient tach  
readings are taken from the fan.  
ADT7470  
PULLUP  
4.7k  
TYP  
TACH  
TACH  
OUTPUT  
FAN SPEED  
COUNTER  
ZD1*  
ZENER  
However, in high frequency fan drive mode, pulse stretching is  
disabled. If using 3-wire fans this mode, care should be taken to  
ensure that incomplete tach information does not occur at low  
PWM duty cycles, or short PWM pulse widths.  
*CHOOSE ZD1 VOLTAGE APPROX. 0.8 V  
CC  
Figure 21. Fan with Tach.  
Pull-Up to voltage > 5 V, for example, 12 V clamped with Zener diode.  
Disabling Tach measurement  
If the fan output has a resistive pull-up to 12 V (or other voltage  
greater than 5 V), the fan output can be clamped with a Zener  
diode, as shown in Figure 21. The Zener diode voltage should  
be chosen so that it is greater than VIH of the tach input but less  
than 5 V, allowing for the voltage tolerance of the Zener. A value  
of between 3 V and 5 V is suitable.  
The tach measurement for each fan can be disabled by writing  
to Configuration Register 2 Bits[3:0], at Address 0x74.  
If the fan has a strong pull-up (less than 1 kΩ) to 12 V, or a  
totem-pole output, a series resistor can be added to limit the  
Zener current, as shown in Figure 22. Alternatively, a resistive  
attenuator can be used, as shown in Figure 23.  
Rev. E | Page 22 of 40  
 
 
 
 
 
 
Data Sheet  
ADT7470  
The fan tachometer reading registers report back the number  
of 11.11 ms period clocks (90 kHz oscillator) gated to the fan  
speed counter, from the rising edge of the first fan tach pulse  
to the rising edge of the third fan tach pulse (assuming 2 pulses  
per revolution are being counted). Since the device is essentially  
measuring the fan tach period, the higher the count value,  
the slower the fan is actually running. A 16-bit fan tachometer  
reading of 0xFFFF indicates either that the fan has stalled or  
is running very slowly (<100 RPM).  
FAN SPEED MEASUREMENT  
The fan counter does not count the fan tach output pulses  
directly, because the fan speed may be less than 1000 RPM, and  
it would take several seconds to accumulate a reasonably large  
and accurate count. Instead, the period of the fan revolution is  
measured by gating an on-chip 90 kHz oscillator into the input  
of a 16-bit counter for N periods of the fan tach output, as shown  
in Figure 24, so the accumulated count is actually proportional  
to the fan tachometer period and inversely proportional to the  
fan speed.  
Fan Tach Limit Registers  
The fan tach limit registers are 16-bit values consisting of two  
bytes. Minimum limits determine fan under speed settings,  
while maximum limits determine fan over speed settings.  
N, the number of pulses counted, is determined by the settings  
of Register 0x43 (fan pulses per revolution register). This register  
contains two bits for each fan, allowing 1, 2 (default), 3, or 4  
tach pulses to be counted.  
Table 20. Fan Tach Limit Registers  
CLOCK  
Register Address  
Description  
Default  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x58  
0x59  
0x5A  
0x5B  
0x5C  
0x5D  
0x5E  
0x5F  
0x60  
0x61  
0x62  
0x63  
0x64  
0x65  
0x66  
0x67  
Tach 1 min low byte  
Tach 1 min high byte  
Tach 2 min low byte  
Tach 2 min high byte  
Tach 3 min low byte  
Tach 3 min high byte  
Tach 4 min low byte  
Tach 4 min high byte  
Tach 1 max low byte  
Tach 1 max high byte  
Tach 2 max low byte  
Tach 2 max high byte  
Tach 3 max low byte  
Tach 3 max high byte  
Tach 4 max low byte  
Tach 4 max high byte  
PWM  
TACH  
1
2
3
4
Figure 24. Fan Speed Measurement  
Fan Speed Measurement Registers  
The fan tachometer readings are 16-bit values consisting of  
a 2-byte read from the ADT7470.  
Table 19. Fan Speed Measurement Registers  
High Limit: Comparison  
Register Address  
Description  
Default  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x2A  
0x2B  
0x2C  
0x2D  
0x2E  
0x2F  
0x30  
0x31  
Tach 1 low byte  
Tach 1 high byte  
Tach 2 low byte  
Tach 2 high byte  
Tach 3 low byte  
Tach 3 high byte  
Tach 4 low byte  
Tach 4 high byte  
Because the actual fan tach period is being measured, exceeding  
a fan tach limit by 1 sets the appropriate status bit and can be  
used to generate an SMBALERT.  
Fan Speed Measurement Rate  
The fan tach readings are updated once every second by default.  
The fast tach bit (Register 0x40 Bit[5]) controls the frequency  
of tach measurements. Setting this bit to 1 increases the tach  
measurements from one per second, to one every 250 ms.  
Reading Fan Speed from the ADT7470  
Measuring fan speed involves a 2-register read for each meas-  
urement. The low byte should be read first. This causes the  
high byte to be frozen until both high and low byte registers  
are read from, preventing erroneous tach readings.  
Rev. E | Page 23 of 40  
 
 
ADT7470  
Data Sheet  
Fan Pulses per Revolution  
Calculating Fan Speed and Tachometer Limits  
Different fan models can output either 1, 2, 3, or 4 tach pulses  
per revolution. The number of tach pulses per rotation for each  
fan should be programmed into the fan pulses per revolution  
register (Register 0x43). If an incorrect value is programmed,  
then the fan speed cannot be determined using the equation in  
the Calculating Fan Speed section.  
Assuming that the measured number of tach pulses per rotation  
corresponds to the number of pulses counted as set in register  
0x43, fan speed is calculated by  
Fan Speed (RPM) = (90,000 × 60)/Fan Tach Reading  
where Fan Tach Reading is the 16-bit fan tachometer reading.  
For example:  
Alternatively, if the number of tach pulses per rotation is not  
know, this register can be used in determining the number  
of pulses/revolution output by a given fan. By plotting fan  
speed measurements at maximum speed with different pulses/  
revolution settings, the smoothest graph with the lowest ripple  
determines the correct pulses/revolution value.  
Tach 1 High Byte (Reg 0x2B) = 0x17  
Tach 1 Low Byte (Reg 0x2A) = 0xFF  
What is Fan 1 speed in RPM?  
Fan 1 tach reading = 0x17FF = 6143 decimal  
RPM = (f × 60)/Fan 1 tach reading  
RPM = (90000 × 60)/6143  
Fan Speed = 879 RPM  
Calculate the tachometer maximum and minimum limits at  
1000 RPM and 500 RPM as follows:  
1000 RPM  
(90,000 × 60)/1000 = 5400 decimal  
5400 decimal = 1518 hex  
Tach 1 maximum = 1518  
500 RPM  
(90,000 × 60)/500 = 10800 decimal  
10800 decimal = 2A30 hex  
Tach 1 minimum = 2A30  
Rev. E | Page 24 of 40  
 
Data Sheet  
ADT7470  
MANUAL FAN SPEED CONTROL  
Manual fan speed control on the ADT7470 allows the user to  
control the PWM duty cycle for each fan via the registers. The  
ADT7470 powers-up in manual fan control mode, with all  
PWM duty cycles set to maximum. The PWM Configuration  
registers determine whether the fans are in manual or automatic  
fan control mode.  
The value to be programmed into the PWM Current Duty  
Cycle registers can be calculated as follows:  
Value (decimal) = Desired PWM duty cycle/0.39  
Example 1: For a PWM Duty Cycle of 50%  
Value (decimal) = 50/0.39 = 128 decimal  
Value = 128 decimal or 80 hex  
SETTING THE PWM DUTY CYCLE  
Example 2: For a PWM Duty Cycle of 33%  
The ADT7470 allows the duty cycle of any PWM output to be  
manually adjusted. This can be useful if users want to change  
fan speed in software or want to adjust PWM duty cycle output  
for test purposes. The PWM current duty cycle registers  
(Register 0x32 to Register 0x35) can be written with 8-bit  
values in manual fan speed control mode to manually adjust  
the speeds of the cooling fans.  
Value (decimal) = 33/0.39 = 85 decimal  
Value = 85 decimal or 54 hex  
Table 21. PWM Current Duty Cycle Registers  
Register Address  
Description  
Default  
0x32  
0x33  
0x34  
0x35  
PWM1 duty cycle  
PWM2 duty cycle  
PWM3 duty cycle  
PWM4 duty cycle  
0xFF (100%)  
0xFF (100%)  
0xFF (100%)  
0xFF (100%)  
The PWM duty cycle for each output can be set anywhere from  
0% to 100%, in steps of 0.39%.  
Table 22.Fan Control Mode Configuration  
Register/Bit  
Mnenonic  
Description  
This bit determines fan behavior for PWM2 output.  
0 = Manual mode (PWM2 duty cycle controlled in software).  
0x68 Bit[6]  
BHVR2  
1 = Fastest speed calculated by all temperatures control PWM2 (automatic fan control mode).  
0x68 Bit[7]  
0x69 Bit[6]  
0x69 Bit[7]  
BHVR1  
BHVR4  
BHVR3  
This bit determines fan behavior for PWM1 output.  
0 = Manual mode (PWM1 duty cycle controlled in software).  
1 = Fastest speed calculated by all temperatures control PWM1 (automatic fan control mode).  
This bit determines fan behavior for PWM4 output.  
0 = Manual mode (PWM4 duty cycle controlled in software).  
1 = Fastest speed calculated by all temperatures control PWM4 (automatic fan control mode).  
This bit determines fan behavior for PWM3 output.  
0 = Manual mode (PWM3 duty cycle controlled in software).  
1 = Fastest speed calculated by all temperatures control PWM3 (automatic fan control mode).  
Rev. E | Page 25 of 40  
 
 
 
ADT7470  
Data Sheet  
AUTOMATIC FAN SPEED CONTROL  
In automatic fan speed control mode, fan speed automatically  
varies with temperature and without CPU intervention, once  
initial parameters are set up. The advantage is that when a  
system hangs, the user is guaranteed that the system is protected  
from overheating.  
PWM Min Duty Cycle  
The PWM min duty cycle registers, at address 0x6A to 0x6D,  
set the PWM duty cycle at which the fans turn on in automatic  
fan control mode.  
The value to be programmed into the PWM Min Duty Cycle  
registers can be calculated as follows:  
Automatic fan speed control mode is recommended for use  
only when temperatures > 8°C. In automatic fan control mode,  
if the temperature drops below 0°C, the fans automatically  
turn on.  
Value (decimal) = Desired PWM duty cycle/0.39  
Example: For a PWM Min Duty Cycle of 30%  
Value (decimal) = 30/0.39 = 77 decimal  
Value = 77 decimal or 4D hex  
For each thermal zone, when the temperature exceeds TMIN  
the fans turn on at PWMMIN duty cycle. When the temperature  
,
reaches TMIN + 20°C, the fans increase in speed to PWMMAX  
.
The PWM min duty cycle registers have a default value of  
0x80, which corresponds to a duty cycle of 50% on the PWM  
output pin.  
To configure each fan into automatic fan control mode, the  
BHVR bit for that fan must be set to 1. See Table 22 for more  
details.  
PWN Max Duty Cycle  
To control the fans in automatic fan control mode, a number of  
parameters for each fan should be set up. The PWM minimum  
and maximum duty cycles, as well as the minimum temperature  
at which each fan turns on, should be configured. Which  
TMP05 controls which fan also needs to be configured.  
For each fan, the maximum PWM duty cycle can be set by  
writing to Registers 0x38 to 0x3B.  
The value to be programmed into the PWM max duty cycle  
registers can be calculated as follows:  
Value (decimal) = Desired PWM duty cycle/0.39  
What follows are the automatic fan control configuration steps:  
Example: For a PWM Max Duty Cycle of 90%  
1. Put the fans into automatic fan control mode, by setting  
the BHVR bits for each fan to 1.  
Value (decimal) = 90/0.39 = 230 decimal  
Value = 230 decimal or E6 hex  
2. Determine which TMP05 is to control the fan, by  
configuring Registers 0x7C and 0x7D. Any TMP05, can  
control any fan, or the hottest TMP05 can control the fan.  
The PWM max duty cycle registers have a default value of 0xFF,  
which corresponds to a Logic 1 on the PWM output pin.  
PWM Current Duty Cycle  
3. Set the minimum temperature for each fan, by writing to  
Registers 0x6E to 0x70. When the temperature exceeds  
In automatic fan control mode, the current PWM duty cycle for  
each fan is recorded in the PWM current duty cycle registers,  
(0x02 to 0x35). By reading these registers, the user can keep  
track of the current duty cycle on each PWM output. During  
fan start up, these registers report back 0x00.  
T
MIN, the fan runs at PWMMIN.  
4. Set PWMMIN, the minimum PWM duty cycle, by writing to  
Registers 0x6A to 0x6D.  
5. Set PWMMAX, the maximum PWM duty cycle, by writing  
to registers 0x38 to 0x3B.  
FULLSPEED  
If the  
pin is activated, to blast the fans to the  
maximum possible PWM ( logic high), the PWM current duty  
cycle register is not updated.  
6. Write to the STRT bit in Configuration Register 1 (0x40  
Bit[0]) to start the ADT7470 monitoring cycle. Set Bit 7 in  
this register to 1 to enable the TMP05 start pulse.  
Rev. E | Page 26 of 40  
 
Data Sheet  
ADT7470  
REGISTER MAP  
Table 23. ADT7470 Register Map  
Address  
0x20  
0x21  
0x22  
0x23  
0x24  
0x25  
0x26  
0x27  
0x28  
0x29  
0x2A  
0x2B  
0x2C  
0x2D  
0x2E  
0x2F  
0x30  
0x31  
0x32  
0x33  
0x34  
0x35  
0x36  
0x37  
0x38  
0x39  
0x3A  
0x3B  
0x3C  
0x3D  
0x3E  
0x3F  
0x40  
0x41  
0x42  
0x43  
0x44  
0x45  
0x46  
0x47  
0x48  
0x49  
0x4A  
0x4B  
0x4C  
0x4D  
0x4E  
0x4F  
0x50  
0x51  
0x52  
0x53  
R/W  
Description  
Default  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0x00  
0x00  
0xFF  
0xFF  
0xFF  
0xFF  
0x00  
0x70  
0x41  
0x02  
0x01  
0xXX  
0xXX  
0x55  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
Lockable  
R
R
R
R
R
R
R
R
Temperature 1 Reading  
Temperature 2 Reading  
Temperature 3 Reading  
Temperature 4 Reading  
Temperature 5 Reading  
Temperature 6 Reading  
Temperature 7 Reading  
Temperature 8 Reading  
Temperature 9 Reading  
Temperature 10 Reading  
Tach 1 Low Byte  
Tach 1 High Byte  
Tach 2 Low Byte  
Tach 2 High Byte  
Tach 3 Low Byte  
Tach 3 High Byte  
Tach 4 Low Byte  
Tach 4 High Byte  
R
R
R
R
R
R
R
R
R
R
R/W  
R/W  
R/W  
R/W  
R
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
PWM1 Current Duty Cycle  
PWM2 Current Duty Cycle  
PWM3 Current Duty Cycle  
PWM4 Current Duty Cycle  
Reserved  
ADI Test Register 1  
y
y
PWM1 Max Duty Cycle  
PWM2 Max Duty Cycle  
PWM3 Max Duty Cycle  
PWM4 Max Duty Cycle  
ADI Test Register 2  
Device ID Register  
Company ID Number  
Revision Number  
R
R
R/W  
R
R
Configuration Register 1  
Interrupt Status Register 1  
Interrupt Status Register 2  
Fan Pulses per Revolution  
Temperature 1 Low Limit  
Temperature 1 High Limit  
Temperature 2 Low Limit  
Temperature 2 High Limit  
Temperature 3 Low Limit  
Temperature 3 High Limit  
Temperature 4 Low Limit  
Temperature 4 High Limit  
Temperature 5 Low Limit  
Temperature 5 High Limit  
Temperature 6 Low Limit  
Temperature 6 High Limit  
Temperature 7 Low Limit  
Temperature 7 High Limit  
Temperature 8 Low Limit  
Temperature 8 High Limit  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Rev. E | Page 27 of 40  
 
ADT7470  
Data Sheet  
Address  
0x54  
0x55  
0x56  
0x57  
0x58  
0x59  
0x5A  
0x5B  
0x5C  
0x5D  
0x5E  
0x5F  
0x60  
0x61  
0x62  
0x63  
0x64  
0x65  
0x66  
0x67  
0x68  
0x69  
0x6A  
0x6B  
0x6C  
0x6D  
0x6E  
0x6F  
0x70  
0x71  
0x72  
0x73  
0x74  
0x75  
0x76  
0x77  
0x78  
0x79  
0x7A  
0x7B  
0x7C  
0x7D  
0x7E  
0x7F  
0x80  
0x81  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
Description  
Default  
0x81  
0x7F  
0x81  
0x7F  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x80  
0x80  
0x80  
0x80  
0x5A  
0x5A  
0x5A  
0x5A  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
Lockable  
Temperature 9 Low Limit  
Temperature 9 High Limit  
Temperature 10 Low Limit  
Temperature 10 High Limit  
Tach 1 Min Low Byte  
Tach 1 Min High Byte  
Tach 2 Min Low Byte  
Tach 2 Min High Byte  
Tach 3 Min Low Byte  
Tach 3 Min High Byte  
Tach 4 Min Low Byte  
Tach 4 Min High Byte  
Tach 1 Max Low Byte  
Tach 1 Max High Byte  
Tach 2 Max Low Byte  
Tach 2 Max High Byte  
Tach 3 Max Low Byte  
Tach 3 Max High Byte  
Tach 4 Max Low Byte  
Tach 4 Max High Byte  
PWM1/2 Config Register  
PWM3/4 Config Register  
PWM1 Min Duty Cycle  
PWM2 Min Duty Cycle  
PWM3 Min Duty Cycle  
PWM4 Min Duty Cycle  
Temperature 1 TMIN  
y
y
y
y
y
y
Temperature 2 TMIN  
Temperature 3 TMIN  
Temperature 4 TMIN  
Interrupt Mask 1 Register  
Interrupt Mask 2 Register  
Configuration Register 2  
Reserved. Do not write to this register.  
Reserved. Do not write to this register.  
ADI Test Register 3  
y
Max TMP05 Temperature  
Reserved. Do not write to this register.  
Reserved. Do not write to this register.  
Reserved. Do not write to this register.  
TMP05 Zone Select 1  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
TMP05 Zone Select 2  
Reserved. Do not write to this register.  
GPIO Enable  
GPIO Config  
GPIO Status  
Rev. E | Page 28 of 40  
Data Sheet  
ADT7470  
DETAILED REGISTER DESCRIPTIONS  
Table 24. Register 0x20 to Register 0x29. Temperature Reading Registers (Power-On Default = 0x00).  
Register  
Address Read/Write Description  
Comments  
0x20  
0x21  
0x22  
0x23  
0x24  
0x25  
0x26  
0x27  
0x28  
0x29  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
8-bit Temperature 1 reading (from TMP05 sensor).  
8-bit Temperature 2 reading (from TMP05 sensor).  
8-bit Temperature 3 reading (from TMP05 sensor).  
8-bit Temperature 4 reading (from TMP05 sensor).  
8-bit Temperature 5 reading (from TMP05 sensor).  
8-bit Temperature 6 reading (from TMP05 sensor).  
8-bit Temperature 2 reading (from TMP05 sensor).  
8-bit Temperature 3 reading (from TMP05 sensor).  
8-bit Temperature 4 reading (from TMP05 sensor).  
8-bit Temperature 5 reading (from TMP05 sensor).  
Bit[7] = Sign bit, indicates if temperature is positive or  
negative  
Bits[6:0] = temperature result  
To calculate the temperature:  
Positive Temperature = ADC Code (decimal)  
Negative Temperature = ADC (decimal) minus 256  
Readings from daisy-chained TMP05 are processed and loaded into the temperature reading registers.  
Table 25. Register 0x2A to Register 0x31. Fan Tach Reading Registers (Power-On Default = 0x00).  
Register Address  
Read/Write  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Description  
0x2A  
0x2B  
0x2C  
0x2D  
0x2E  
0x2F  
0x30  
0x31  
Tach 1 low byte (8 MSBs of reading).  
Tach 1 high byte (8 LSBs of reading).  
Tach 2 high byte (8 MSBs of reading).  
Tach 2 low byte (8 LSBs of reading).  
Tach 3 high byte (8 MSBs of reading).  
Tach 3 low byte (8 LSBs of reading).  
Tach 4 high byte (8 MSBs of reading).  
Tach 4 low byte (8 LSBs of reading).  
The fan tach reading registers shown in Table 25 count the number of 11.11 µs periods (based on an internal 90 kHz clock) that occur  
between a number of consecutive fan tach pulses (default = 2). The number of tach pulses used to count can be changed using the fan  
pulses per revolution register (Register 0x43). This allows the fan speed to be accurately measured. Because a valid fan tachometer  
reading requires that two bytes are read, the low byte must be read first. Both the low and high bytes are then frozen until read. At power-  
on, these registers contain 0x0000 until such time as the first valid fan tach measurement is read in to these registers. This prevents false  
interrupts from occurring while the fans are spinning up.  
A count of 0xFFFF indicates that a fan is  
Stalled or blocked (object jamming the fan).  
Failed (internal circuitry destroyed).  
Not populated. The ADT7470 expects to see a fan connected to each tach. If a fan is not connected to that tach,  
its tach minimum high and low byte are set to 0xFFFF.  
Table 26. Register 0x32 to Register 0x35. Current PWM Duty Cycle Registers (Power-On Default = 0xFF).  
Register Address  
Read/Write Description  
0x32  
0x33  
0x34  
0x35  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
PWM1 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).  
PWM2 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).  
PWM3 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).  
PWM4 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).  
The current PWM duty cycle registers, shown in Table 26, reflect the PWM duty cycle driving each fan at any given time. When in  
automatic fan speed control mode, the ADT7470 reports the PWM duty cycles back through these registers. The PWM duty cycle values  
vary according to temperature in automatic fan speed control mode. During fan startup, these registers report back 0x00. In manual fan  
control mode, the PWM duty cycle outputs can be set to any duty cycle value by writing to these registers.  
Rev. E | Page 29 of 40  
 
 
 
ADT7470  
Data Sheet  
Table 27. Register 0x38 to Register 0x3B. PWM Max Duty Cycle Registers (Power-On Default = 0xFF).  
Register Address  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
0x38  
0x39  
0x3A  
0x3B  
PWM1 max duty cycle: PWM1 Min duty cycle value (register 0x6A) to 100% duty cycle.  
PWM2 max duty cycle: PWM2 Min duty cycle value (register 0x6B) to 100% duty cycle.  
PWM3 max duty cycle: PWM3 Min duty cycle value (register 0x6C) to 100% duty cycle.  
PWM4 max duty cycle: PWM4 Min duty cycle value (register 0x6D) to 100% duty cycle.  
Table 28. Register 0x3D. Device ID Register (Power-On Default = 0x70).  
Register Address  
Read/Write  
Description  
0x3D  
Read only  
Device ID.  
The device ID register contains the ADT7470 device ID value as a means of identifying the part over the bus.  
Table 29. Register 0x3E. Company ID Register (Power-On Default = 0x41).  
Register Address  
Read/Write  
Description  
0x3E  
Read only  
Company ID.  
The company ID register contains 0x41, the manufacturer ID number representative of the Analog Devices, Inc. product.  
Table 30. Register 0x3F. Revision Register (Power-On Default = 0x02).  
Register Address  
Read/Write  
Description  
0x3F  
Read only  
Revision Register.  
The revision register contains the revision number of the ADT7470.  
Table 31. Register 0x40. Configuration Register 1 (Power-On Default = 0x01).  
Bit Name  
Read/Write  
Description  
[0] STRT  
Read/Write  
Logic 1 enables monitoring and PWM control outputs based on the limit settings  
programmed.  
Logic 0 disables monitoring and PWM control based on the default power-up limit settings.  
The limit values programmed are preserved even if a Logic 0 is written to this bit and the  
default settings are enabled.  
[1] Reserved  
[2] Reserved  
[3] TODIS  
Read/Write  
Read/Write  
Read/Write  
Write Once  
Reserved. Write 0 to this bit.  
Reserved. Write 0 to this bit.  
Writing a 1 disables SMBus timeout.  
Once this bit is set, all lockable registers become read-only and cannot be modified until the  
ADT7470 is powered down and powered up again.  
[4] LOCK  
[5] FST_TCH  
[6] HF_LF  
Read/Write  
Enable Fast Tach measurement.  
0 = Tach measurement rate is 1 measurement per second  
1= Tach measurement rate is 1 measurement every 250ms  
This bit switches between high frequency and low frequency fan drive.  
0 (default) = high frequency fan drive (1.4 kHz or 22.5 kHz. See Configuration Register 2,  
Register 0x74, Bits [6:4]) in Table 44.  
Read/Write  
1 = low frequency fandrive (frequency determined by Configuration Register 2, Register 0x74,  
Bits[6:4]) in Table 44.  
[7] T05_STB  
Read/Write  
Select configuration for Pin 13.  
0 (default) =FULL SPEED input.  
1 = TMP05 start pulse output.  
Rev. E | Page 30 of 40  
 
Data Sheet  
ADT7470  
Table 32. Register 0x41. Interrupt Status Register 1 (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[0] R1T  
Read-only  
A 1 indicates that the Remote 1 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 2 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 3 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 4 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 5 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 6 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 7 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
[1] R2T  
[2] R3T  
[3] R4T  
[4] R5T  
[5] R6T  
[6] R7T  
[7] OOL  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
Read-only  
A 1 indicates that an out-of-limit event has been latched in Status Register 2. This bit is a  
logical OR of all status bits in Status Register 2. Software can test this bit in isolation to  
determine whether any of the temperature or fan speed readings represented by Status  
Register 2 are out of limit. This saves the need to read Status Register 2 every interrupt or  
polling cycle.  
Table 33. Register 0x42. Interrupt Status Register 2 (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[0] R8T  
Read-only  
A 1 indicates that the Remote 8 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 9 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
A 1 indicates that the Remote 10 temperature high or low limit has been exceeded.  
This bit is cleared on a read of the status register only if the error condition has subsided.  
[1] R9T  
Read-only  
Read-only  
Read-only  
[2] R10T  
[3] NORM  
A 1 indicates that the measured temperatures are normal (below TMIN), and the fans should  
be off.  
[4] Fan 1  
[5] Fan 2  
[6] Fan 3  
[7] Fan 4  
Read-only  
Read-only  
Read-only  
Read-only  
A 1 indicates that Fan 1 has gone above max speed or dropped below min speed.  
A 1 indicates that Fan 2 has gone above max speed or dropped below min speed.  
A 1 indicates that Fan 3 has gone above max speed or dropped below min speed.  
A 1 indicates that Fan 4 has gone above max speed or dropped below min speed.  
Rev. E | Page 31 of 40  
ADT7470  
Data Sheet  
Table 34. Register 0x43. Fan Pulses per Revolution Register (Power-On Default = 0x55).  
Bit Name  
Read/Write  
Description  
[1:0] Fan 1  
Read/Write  
Sets the number of pulses to be counted when measuring Fan 1 speed.  
Can be used to determine fan’s pulses per revolution number for unknown fan type.  
Pulses Counted  
00 = 1  
01 = 2 (default)  
10 = 3  
11 = 4  
[3:2] Fan 2  
[5:4] Fan 3  
[7:6] Fan 4  
Read/Write  
Read/Write  
Read/Write  
Sets the number of pulses to be counted when measuring Fan 2 speed.  
Can be used to determine fan’s pulses per revolution number for unknown fan type.  
Pulses Counted  
00 = 1  
01 = 2 (default)  
10 = 3  
11 = 4  
Sets the number of pulses to be counted when measuring Fan 3 speed.  
Can be used to determine fan’s pulses per revolution for unknown fan type.  
Pulses Counted  
00 = 1  
01 = 2 (default)  
10 = 3  
11 = 4  
Sets the number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan’s  
pulses per revolution for unknown fan type.  
Pulses Counted  
00 = 1  
01 = 2 (default)  
10 = 3  
11 = 4  
Table 35. Register 0x44 to Register 0x57. Temperature Limit Registers.  
Register Address  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
Power-On Default  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x81  
0x7F  
0x44  
0x45  
0x46  
0x47  
0x48  
0x49  
0x4A  
0x4B  
0x4C  
0x4D  
0x4E  
0x4F  
0x50  
0x51  
0x52  
0x53  
0x54  
0x55  
Temperature 1 low limit  
Temperature 1 high limit  
Temperature 2 low limit  
Temperature 2 high limit  
Temperature 3 low limit  
Temperature 3 high limit  
Temperature 4 low limit  
Temperature 4 high limit  
Temperature 5 low limit  
Temperature 5 high limit  
Temperature 6 low limit  
Temperature 6 high limit  
Temperature 7 low limit  
Temperature 7 high limit  
Temperature 8 low limit  
Temperature 8 high limit  
Temperature 9 low limit  
Temperature 9 high limit  
Temperature 10 low limit  
Temperature 10 high limit  
0x81  
0x7F  
0x81  
0x7F  
0x56  
0x57  
Exceeding any of the temperature limits shown in Table 35 by 1°C causes the appropriate status bit to be set in the interrupt status registers.  
High limits: An interrupt is generated when a value exceeds its high limit (> comparison).  
Low limits: An interrupt is generated when a value is equal to or below its low limit (comparison).  
Rev. E | Page 32 of 40  
 
Data Sheet  
ADT7470  
Table 36. Register 0x58 to Register 0x67. Fan Tachometer Limit Registers.  
Register Address  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
Power-On Default  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0xFF  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x58  
0x59  
0x5A  
0x5B  
0x5C  
0x5D  
0x5E  
0x5F  
0x60  
0x61  
0x62  
0x63  
0x64  
0x65  
0x66  
0x67  
Tach 1 min low byte  
Tach 1 min high byte  
Tach 2 min low byte  
Tach 2 min high byte  
Tach 3 min low byte  
Tach 3 min high byte  
Tach 4 min low byte  
Tach 4 min high byte  
Tach 1 max low byte  
Tach 1 max high byte  
Tach 2 max low byte  
Tach 2 max high byte  
Tach 3 max low byte  
Tach 3 max high byte  
Tach 4 max low byte  
Tach 4 max high byte  
Exceeding any of the tach min limit registers shown in Table 36 by 1 indicates that the fan is running too slowly or has stalled.  
The appropriate status bit is set in Interrupt Status Register 2 to indicate the fan failure.  
Exceeding any of the tach max limit registers by 1 indicates that the fan is too fast. The appropriate status bit is set in Interrupt Status  
Register 2 to indicate the fan failure.  
Table 37. Register 0x68. PWM1/PWM2 Configuration Register (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[0]  
N/A  
Set to 0 (default).  
[1]  
N/A  
Set to 0 (default).  
[2]  
N/A  
Set to 0 (default).  
[3]  
N/A  
Set to 0 (default).  
[4] INV2  
[5] INV1  
[6] BHVR2  
Read/Write  
Read/Write  
Read/Write  
Setting this bit to 1 inverts the PWM2 output. Default = 0.  
Setting this bit to 1 inverts the PWM1 output. Default = 0.  
This bit assigns fan behavior for PWM2 output.  
0 = manual fan control mode (PWM duty cycle controlled in software).  
1 = automatic fan control mode  
[7] BHVR1  
Read/Write  
This bit assigns fan behavior for PWM1 output.  
0 = manual fan control mode (PWM duty cycle controlled in software).  
1 = automatic fan control mode.  
Rev. E | Page 33 of 40  
 
ADT7470  
Data Sheet  
Table 38. Register 0x69. PWM3/PWM4 Configuration Register (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[0]  
N/A  
Set to 0 (default).  
[1]  
N/A  
Set to 0 (default).  
[2]  
N/A  
Set to 0 (default).  
[3]  
N/A  
Set to 0 (default).  
[4] INV4  
[5] INV3  
[6] BHVR4  
Read/Write  
Read/Write  
Read/Write  
Setting this bit to 1 inverts the PWM4 output. Default = 0  
Setting this bit to 1 inverts the PWM3 output. Default = 0  
This bit assigns fan behavior for PWM4 output.  
0 = manual fan control mode (PWM duty cycle controlled in software).  
1 = (automatic fan control mode.  
[7] BHVR3  
Read/Write  
This bit assigns fan behavior for PWM3 output.  
0 = manual fan control mode (PWM duty cycle controlled in software).  
1 = automatic fan control mode.  
Table 39. Register 0x6A to Register 0x6D. PWMMIN Duty Cycle Registers (Power-On Default = 0x80 (50% Duty Cycle).  
Register Address  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
0x6A  
0x6B  
0x6C  
0x6D  
PWM1 min duty cycle.  
PWM2 min duty cycle.  
PWM3 min duty cycle.  
PWM4 min duty cycle.  
Table 40. PWMMIN Duty Cycle Registers Detailed Description  
Bit Name  
Read/Write  
Description  
[7:0] PWM Duty Cycle  
Read/Write  
These bits define the PWNMIN duty cycle for PWMx (x = 1 to 4).  
0x00 = 0% duty cycle (fan off).  
0x40 = 25% duty cycle.  
0x80 = 50% duty cycle.  
0xFF = 100% PMW max duty cycle (full fan speed).  
Table 41. Register 0x6E to Register 0x71. TMIN Registers (Power-On Default = 0x5A (90°C)).  
Register Address  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
0x6E  
0x6F  
0x70  
0x71  
Temperature 1 TMIN  
Temperature 2 TMIN  
Temperature 3 TMIN  
Temperature 4 TMIN  
.
.
.
.
Table 41 shows the TMIN registers for each thermal zone. When the temperature measured exceeds TMIN, the appropriate fan runs at  
minimum speed (PWMMIN). They increase to maximum speed (PWMMAX) at TMIN + 20°C.  
Rev. E | Page 34 of 40  
 
Data Sheet  
ADT7470  
Table 42. Register 0x72. Interrupt Mask Register 1 (Power-On Default = 0x00).  
Bit Name  
[7] Not in use  
[6] R7T  
Read/Write  
Read/Write  
Read/Write  
Description  
Not in use. Write 0 to this bit.  
A 1 masks the Temperature 7 value from generating an interrupt on the SMBALERT  
output. The R1T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 6 value from generating an interrupt on the SMBALERT  
output. The R2T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 5 value from generating an interrupt on the SMBALERT  
output. The R3T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 4 value from generating an interrupt on the SMBALERT  
output. The R4T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 3 value from generating an interrupt on the SMBALERT  
output. The R5T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 2 value from generating an interrupt on the SMBALERT  
output. The R6T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 1 value from generating an interrupt on the SMBALERT  
output. The R7T bit is set as normal in the status register for out-of-limit conditions.  
[5] R6T  
[4] R5T  
[3] R4T  
[2] R3T  
[1] R2T  
[0] R1T  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Table 43. Register 0x73. Interrupt Mask Register 2 (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[7] Fan 4  
Read/Write  
A 1 masks the Fan 4 value from generating an interrupt on the SMBALERT output.  
The Fan 4 bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Fan 3 value from generating an interrupt on the SMBALERT output.  
The Fan 3 bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Fan 2 value from generating an interrupt on the SMBALERT output.  
The Fan 2 bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Fan 1 value from generating an interrupt on the SMBALERT output.  
The Fan 1 bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the pulsing of the SMBALERTwhile enabling daisy chain, writing to Bit [7]  
Register 0x40.  
A 1 masks the Temperature 10 value from generating an interrupt on the SMBALERT  
output. The R10T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 9 value from generating an interrupt on the SMBALERT  
output. The R9T bit is set as normal in the status register for out-of-limit conditions.  
A 1 masks the Temperature 8 value from generating an interrupt on the SMBALERT  
output. The R8T bit is set as normal in the status register for out-of-limit conditions.  
[6] Fan 3  
[5] Fan 2  
[4] Fan 1  
[3] Daisy chain  
[2] R10T  
[1] R9T  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
[0] R8T  
Rev. E | Page 35 of 40  
ADT7470  
Data Sheet  
Table 44. Register 0x74. Configuration Register 2 (Power-On Default = 0x00).  
Bit Name  
[7] SHDN  
[6:4] FREQ  
Read/Write  
Read/Write  
Read/Write  
Description  
Shutdown/low current mode.  
These bits control PWM1–PWM4 frequency when the fan drive is configured as a low  
frequency drive.  
Register 0x74[6:4]  
Register 0x40[6] = 1  
11.0 Hz  
14.7 Hz  
22.1 Hz  
29.4 Hz  
35.3 Hz  
44.1 Hz  
58.8 Hz  
88.2 Hz  
Register 0x40[6] = 0  
1.4 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
22.5 kHz  
000  
001  
010  
011  
100  
101  
110  
111  
[3] T4_dis  
[2] T3_dis  
[1] T2_dis  
[0] T1_dis  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Writing a 1 disables Tach 4 measurements.  
Writing a 1 disables Tach 3 measurements.  
Writing a 1 disables Tach 2 measurements.  
Writing a 1 disables Tach 1 measurements.  
Table 45. Register 0x78. Max TMP05 Temperature (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[7:0] TMP05_MAX  
Read-only  
This register indicates the maximum of all TMP05 temperatures.  
Table 46. Register 0x7C. TMP05 Zone Select 1 (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[7:4] zone_fan1[3:0]  
Read/Write  
These bits determine which temperature zone controls Fan 1.  
zone_fan1[3:0]  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
Description  
max_temperature from Register 0x78 controls Fan 1.  
Temperature 1 from Register 0x20 controls Fan 1.  
Temperature 2 from Register 0x21 controls Fan 1.  
Temperature 3 from Register 0x22 controls Fan 1.  
Temperature 4 from Register 0x23 controls Fan 1.  
Temperature 5 from Register 0x24 controls Fan 1.  
Temperature 6 from Register 0x25 controls Fan 1.  
Temperature 7 from Register 0x26 controls Fan 1.  
Temperature 8 from Register 0x27 controls Fan 1.  
Temperature 9 from Register 0x28 controls Fan 1.  
Temperature 10 from Register 0x29 controls Fan 1.  
1000  
1001  
1010  
[3:0] zone_fan2[3:0]  
Read/Write  
These bits determine which temperature zone controls Fan 2.  
zone_fan2[3:0]  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
Description  
max_temperature from Register 0x78 controls Fan 2.  
Temperature 1 from Register 0x20 controls Fan 2.  
Temperature 2 from Register 0x21 controls Fan 2.  
Temperature 3 from Register 0x22 controls Fan 2.  
Temperature 4 from Register 0x23 controls Fan 2.  
Temperature 5 from Register 0x24 controls Fan 2.  
Temperature 6 from Register 0x25 controls Fan 2.  
Temperature 7 from Register 0x26 controls Fan 2.  
Temperature 8 from Register 0x27 controls Fan 2.  
Temperature 9 from Register 0x28 controls Fan 2.  
Temperature 10 from Register 0x29 controls Fan 2.  
1000  
1001  
1010  
Rev. E | Page 36 of 40  
 
Data Sheet  
ADT7470  
Table 47. Register 0x7D. TMP05 Zone Select 2 (Power-On Default = 0x00).  
Description  
Bit Name  
Read/Write  
[7:4] zone_fan3[3:0]  
Read/Write  
These bits determine which temperature zone controls Fan 3.  
zone_fan3[3:0]  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
Description  
max_temperature from Register 0x78 controls Fan 3.  
Temperature 1 from Register 0x20 controls Fan 3.  
Temperature 2 from Register 0x21 controls Fan 3.  
Temperature 3 from Register 0x22 controls Fan 3.  
Temperature 4 from Register 0x23 controls Fan 3.  
Temperature 5 from Register 0x24 controls Fan 3.  
Temperature 6 from Register 0x25 controls Fan 3.  
Temperature 7 from Register 0x26 controls Fan 3.  
Temperature 8 from Register 0x27 controls Fan 3.  
Temperature 9 from Register 0x28 controls Fan 3.  
Temperature 10 from Register 0x29 controls Fan 3.  
1000  
1001  
1010  
[3:0] zone_fan4[3:0]  
Read/Write  
These bits determine which temperature zone controls Fan 4.  
zone_fan4[3:0]  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
Description  
max_temperature from Register 0x78 controls Fan 4.  
Temperature 1 from Register 0x20 controls Fan 4.  
Temperature 2 from Register 0x21 controls Fan 4.  
Temperature 3 from Register 0x22 controls Fan 4.  
Temperature 4 from Register 0x23 controls Fan 4.  
Temperature 5 from Register 0x24 controls Fan 4.  
Temperature 6 from Register 0x25 controls Fan 4.  
Temperature 7 from Register 0x26 controls Fan 4.  
Temperature 8 from Register 0x27 controls Fan 4.  
Temperature 9 from Register 0x28 controls Fan 4.  
Temperature 10 from Register 0x29 controls Fan 4.  
1000  
1001  
1010  
Table 48. Register 0x7F. GPIO Enable (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Description  
[7:6] Reserved  
[5:4] Reserved  
[3] GPIO1_en  
[2] GPIO2_en  
[1] GPIO3_en  
[0] GPIO4_en  
Reserved. Write 0x0 to these bits.  
Reserved. This bit should be set to 0.  
PWM1 becomes a GPIO.  
PWM2 becomes a GPIO.  
PWM3 becomes a GPIO.  
PWM4 becomes a GPIO.  
Rev. E | Page 37 of 40  
ADT7470  
Data Sheet  
Table 49. Register 0x80. GPIO CONFIG (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[7] GPIO1_d  
Read/Write  
This bit sets the direction of GPIO 1 when the PWM1 pin is configured as GPIO.  
1 = output; 0 = input.  
Data for GPIO 1 is set by the LSB of the PWM1 min duty cycle register.  
This bit sets the polarity of GPIO 1 when the PWM1 pin is configured as GPIO.  
1 = active high; 0 = active low.  
This bit sets the direction of GPIO 2 when the PWM2 pin is configured as GPIO.  
1= output; 0 = input.  
[6] GPIO1_p  
[5] GPIO2_d  
Read/Write  
Read/Write  
Data for GPIO 2 is set by the LSB of the PWM2 min duty cycle register.  
This bit sets the polarity of GPIO 2 when the PWM2 pin is configured as GPIO.  
1 = active high; 0 = active low.  
This bit sets the direction of GPIO 3 when the PWM3 pin is configured as GPIO.  
1= output; 0 = input.  
[4] GPIO2_p  
[3] GPIO3_d  
Read/Write  
Read/Write  
Data for GPIO 3 is set by the LSB of the PWM3 min duty cycle register.  
This bit sets the polarity of GPIO 3 when the PWM3 pin is configured as GPIO.  
1 = active high; 0 = active low.  
This bit sets the direction of GPIO 4 when the PWM4 pin is configured as GPIO.  
1= output; 0 = input.  
[2] GPIO3_p  
[1] GPIO4_d  
Read/Write  
Read/Write  
Data for GPIO 4 is set by the LSB of the PWM4 min duty cycle register.  
This bit sets the polarity of GPIO 4 when the PWM4 pin is configured as GPIO.  
1 = active high; 0 = active low.  
[0] GPIO4_p  
Read/Write  
Table 50. Register 0x81. GPIO Status (Power-On Default = 0x00).  
Bit Name  
Read/Write  
Description  
[7:4] GPIO_s  
Read/Write  
These bits indicate the status of the GPIO when the corresponding PWM pin is configured  
as GPIO.  
When GPIO is configured as an input, these bits are read-only. They are set when the input  
is asserted. (Asserted can be high or low depending on the setting of the GPIO polarity.)  
When GPIO is configured as an output, these bits are read/write. Setting these bits asserts  
the GPIO output. (Asserted can be high or low depending on the setting of GPIO4  
polarity.)  
[7] GPIO4_s  
[6] GPIO3_s  
[5] GPIO2_s  
[4] GPIO1_s  
[3:0] Reserved  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
Read/Write  
This bit indicates the status of GPIO 4 when the PWM4 pin is configured as GPIO.  
This bit indicates the status of GPIO 3 when the PWM3 pin is configured as GPIO.  
This bit indicates the status of GPIO 2 when the PWM2 pin is configured as GPIO.  
This bit indicates the status of GPIO 1 when the PWM1 pin is configured as GPIO.  
Test Bit. For Analog Devices use only.  
Rev. E | Page 38 of 40  
Data Sheet  
ADT7470  
OUTLINE DIMENSIONS  
0.197 (5.00)  
0.193 (4.90)  
0.189 (4.80)  
16  
1
9
8
0.158 (4.01)  
0.154 (3.91)  
0.150 (3.81)  
0.244 (6.20)  
0.236 (5.99)  
0.228 (5.79)  
0.010 (0.25)  
0.006 (0.15)  
0.020 (0.51)  
0.010 (0.25)  
0.069 (1.75)  
0.053 (1.35)  
0.065 (1.65)  
0.049 (1.25)  
0.010 (0.25)  
0.004 (0.10)  
0.041 (1.04)  
REF  
SEATING  
PLANE  
8°  
0°  
0.025 (0.64)  
BSC  
0.050 (1.27)  
0.016 (0.41)  
COPLANARITY  
0.004 (0.10)  
0.012 (0.30)  
0.008 (0.20)  
COMPLIANT TO JEDEC STANDARDS MO-137-AB  
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS  
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR  
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.  
Figure 25. 16-Lead Shrink Small Outline Package [QSOP]  
(RQ-16)  
Dimensions shown in inches and (millimeters)  
ORDERING GUIDE  
Model1  
ADT7470ARQZ  
ADT7470ARQZ-REEL  
ADT7470ARQZ-REEL7  
EVAL-ADT7470EBZ  
Temperature Range  
−40°C to +125°C  
−40°C to +125°C  
−40°C to +125°C  
Package Description  
16-Lead QSOP  
16-Lead QSOP  
16-Lead QSOP  
Evaluation Board  
Package Option  
RQ-16  
RQ-16  
RQ-16  
1 Z = RoHS Compliant Part.  
Rev. E | Page 39 of 40  
 
 
ADT7470  
NOTES  
Data Sheet  
Purchase of licensed I2C components of Analog Devices or one of its sublicensed Associated Companies conveys a license for the purchaser under the Philips I2C Patent  
Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips.  
©2004–2013 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective owners.  
D04684-0-4/13(E)  
Rev. E | Page 40 of 40  

相关型号:

EVAL-ADT7483EB

Dual Channel Temperature Sensor and Over Temperature Alarm
ONSEMI

EVAL-ADT7490EBZ

dBCool Remote Thermal Monitor and Fan Controller with PECI Interface
ADI

EVAL-ADT7516EB

SPI-/I2C-Compatible, Temperature Sensor,4-Channel ADC and Quad Voltage Output
ADI

EVAL-ADT7X20EBZ

±0.25°C Accurate, 16-Bit Digital I2C Temperature Sensor
ADI

EVAL-ADUC-CABLE1Z

MicroConverter® Multichannel 24-/16-Bit ADCs with Embedded 62 kB Flash and Single-Cycle MCU
ADI

EVAL-ADuC7020MKZ

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU
ADI

EVAL-ADUC7020QS

Precision Analog Microcontroller 12-bit Analog I/O, ARM7TDMI MCU
ADI

EVAL-ADuC7020QSPZ

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU
ADI

EVAL-ADuC7020QSZ

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU
ADI

EVAL-ADuC7023QSPZ

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU with Enhanced IRQ Handler
ADI

EVAL-ADuC7023QSPZ1

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU with Enhanced IRQ Handler
ADI

EVAL-ADuC7023QSPZ2

Precision Analog Microcontroller, 12-Bit Analog I/O, ARM7TDMI MCU with Enhanced IRQ Handler
ADI