HFBR-4503 [AGILENT]

Plastic Optical Fiber Cable and Accessories for Versatile Link; 塑料光纤电缆及附件的通用链接
HFBR-4503
型号: HFBR-4503
厂家: AGILENT TECHNOLOGIES, LTD.    AGILENT TECHNOLOGIES, LTD.
描述:

Plastic Optical Fiber Cable and Accessories for Versatile Link
塑料光纤电缆及附件的通用链接

光纤 连接器 光纤网络连接器
文件: 总11页 (文件大小:270K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Plastic Optical Fiber  
Cable and Accessories for  
Versatile Link  
Technical Data  
HFBR-RXXYYY Series (POF)  
HFBR-EXXYYY Series (POF)  
Features  
Cable Description  
• Compatible with Agilent  
Versatile Link Family of  
Connectors and Fiber Optic  
Components  
• 1 mm Diameter Plastic  
Optical Fiber (POF) in Two  
Grades: Low Cost Standard  
POF with 0.22 dB/m Typical  
Attenuation, or High  
The HFBR-R/EXXYYY series of  
plastic fiber optic cables are  
constructed of a single step-index  
fiber sheathed in a black poly-  
ethylene jacket. The duplex fiber  
consists of two simplex fibers  
joined with a zipcord web.  
Standard attenuation and extra  
low loss POF cables are identical  
except for attenuation  
Performance Extra Low Loss  
POF with 0.19 dB/m Typical  
Attenuation  
500  
400  
300  
specifications.  
Polyethylene jackets on all plastic  
fiber cables comply with UL VW-1  
flame retardant specification (UL  
file # E89328).  
Applications  
• Industrial Data Links for  
Factory Automation and  
Plant Control  
• Intra-System Links; Board-  
to-Board, Rack-to-Rack  
• Telecommunications  
Switching Systems  
• Computer-to-Peripheral Data  
Links, PC Bus Extension  
• Proprietary LANs  
• Digitized Video  
200  
100  
Cables are available in  
unconnectored or connectored  
options. Refer to the Ordering  
Guide for part number  
information.  
620  
640  
660  
680  
700  
λ – WAVELENGTH – nm  
Figure 1. Typical POF Attenuation vs.  
Wavelength.  
• Medical Instruments  
• Reduction of Lightning and  
Voltage Transient  
Susceptibility  
• High Voltage Isolation  
2
Plastic Optical Fiber Specifications: HFBR-R/EXXYYY  
Absolute Maximum Ratings  
Parameter  
Symbol  
Min.  
-55  
Max.  
+85  
+85  
+70  
50  
Unit  
°C  
Note  
Storage and Operating Temperature  
Recommended Operating Temperature  
Installation Temperature  
TS,O  
TO  
TI  
-40  
-20  
°C  
°C  
1
2
Short Term Tensile  
Force  
Single Channel  
Dual Channel  
FT  
FT  
r
N
N
mm  
mm  
N
100  
Short Term Bend Radius  
Long Term Bend Radius  
Long Term Tensile Load  
Flexing  
25  
35  
3, 4  
4
r
FT  
1
1000  
Cycles  
Mechanical/Optical Characteristics, T = -40 to +85°C unless otherwise specified.  
A
Parameter  
Standard Cable,  
Symbol Min. Typ.[5] Max. Unit  
Condition  
Cable  
αO  
0.15  
0.15  
0.12  
0.12  
0.22  
0.19  
0.19  
0.16  
0.27 dB/m Source is HFBR-15XX  
(660 mm LED, 0.5 NA)  
Attenuation  
Type "R"  
Extra Low Loss,  
Type "E"  
0.23  
= 50 meters  
Reference  
Standard Cable,  
Type "R"  
αR  
0.24 dB/m Source is 650 nm,  
0.5 NA monochrometer,  
Attenuation  
Extra Low Loss,  
Type "E"  
0.19  
= 50 meters  
Note 7, Figure 1  
Numerical Aperture  
Diameter, Core and Cladding  
Diameter, Jacket  
Propagation Delay Constant  
Mass per Unit Length/Channel  
Cable Leakage Current  
Refractive Index Core  
Cladding  
NA  
DC  
DJ  
l/v  
0.46  
0.94  
2.13  
0.47  
1.00  
2.20  
5.0  
0.50  
1.06  
2.27  
>2 meters  
mm  
mm  
Simplex Cable  
ns/m Note 6  
5.3  
g/m  
nA  
Without Connectors  
50 kV, = 0.3 meters  
IL  
n
12  
1.492  
1.417  
Notes:  
1. Installation temperature is the range over which the cable can be bent and pulled  
without damage. Below -20°C the cable becomes brittle and should not be subjected to  
mechanical stress.  
2. Short Term Tensile Force is for less than 30 minutes.  
3. Short Term Bend Radius is for less than 1 hour nonoperating.  
4. 90° bend on 25 mm radius mandrel. Bend radius is the radius of the mandrel around  
which the cable is bent.  
5. Typical data are at 25°C.  
6. Propagation delay constant is the reciprocal of the group velocity for propagation delay  
of optical power. Group velocity is v=c/n where c is the velocity of light in free space  
(3xl08 m/s) and n is the effective core index of refraction.  
7. Note that αR rises at the rate of about 0.0067 dB/°C, where the thermal rise refers to  
the LED temperature changes above 25°C. Please refer to Figure 1 which shows the  
typical plastic optical fiber attenuation versus wavelength at 25°C.  
3
Plastic Fiber Connector  
Styles  
Connector Description  
HFBR-4503/4513 — Simplex Latching  
latching connector is available in  
parchment, off-white (HFBR-  
4506).  
HFBR-4525  
Four connector styles areavailable  
for termination of plastic optical  
fiber: simplex, simplex latching,  
duplex and duplex latching. All  
connectors provide a snap-in  
action when mated to Versatile  
Link components. Simplex  
connectors are color coded to  
facilitate identification of trans-  
mitter and receiver connections.  
Duplex connectors are keyed so  
that proper orientation is ensured  
during insertion. If the POF cable/  
connector will be used at extreme  
operating temperatures or  
experience frequent and wide  
temperature cycling effects, the  
cable/connector attachment can  
be strengthened with an RTV  
adhesive (see Plastic Connector-  
ing Instructions for more detail).  
The connectors are made of a  
flame retardant VALOX UL94 V-0  
material (UL file # E121562).  
HFBR-4516 — Duplex Latching  
The simplex latching connector is  
designed for rugged applications  
requiring a greater retention force  
— 80 Newtons ( 18 lb.) — than  
provided by a simplex nonlatching  
connector. When inserting the  
simplex latching connector into a  
module, the connector latch  
mechanism should be aligned  
with the top surface of the  
horizontal modules, or with the  
tall vertical side of the vertical  
modules. Misalignment of an  
inserted latching connector into  
either module will not result in a  
positive latch. The connector is  
released by depressing the rear  
section of the connector lever,  
and then pulling the connector  
assembly away from the module  
housing.  
HFBR-4526  
The duplex latching connector is  
designed for rugged applications  
requiring greater retention force  
than the nonlatching duplex con-  
nector. When inserting the duplex  
latching connector into a module,  
the connector latch mechanism  
should be aligned with the top  
surface of the dual combination of  
horizontal or vertical Versatile  
Link components. The duplex  
latching connector is available in  
gray (HFBR-4516).  
The simplex latching connector is  
available in gray (HFBR-4503) or  
blue (HFBR-4513).  
SIMPLEX CONNECTOR STYLES  
HFBR-4501/4511 — Simplex  
,
Feedthrough/Splice  
HFBR-4505/4515 Bulkhead Adapter  
DUPLEX CONNECTOR STYLES  
HFBR-4506 — Duplex  
, HFBR-4525  
The simplex connector provides a  
quick and stable connection for  
applications that require a  
component-to-connector retention  
force of 8 Newtons (1.8 lb.).  
These connectors are available in  
gray (HFBR-4501) or blue  
(HFBR-4511).  
HFBR-4526  
The HFBR-4505/4515 adapter  
mates two simplex connectors for  
panel/bulkhead feedthrough of  
HFBR-4501/4511 terminated  
plastic fiber cable. Maximum  
panel thickness is 4.1 mm (0.16  
inch). This adapter can serve as a  
cable in-line splice using two  
simplex connectors. The adapters  
are available in gray (HFBR-  
4505) and blue (HFBR-4515).  
This adapter is not compatible  
with POF duplex, POF simplex  
latching, or HCS connectors.  
Duplex connectors provide con-  
venient duplex cable termination  
and are keyed to prevent incorrect  
insertion into duplex configured  
modules. The duplex connector is  
compatible with dual combina-  
tions of horizontal or vertical  
Versatile Link components (e.g.,  
two horizontal transmitters, two  
vertical receivers, a horizontal  
transmitter with a horizontal  
receiver, etc.). The duplex non-  
4
Plastic Optical Fiber Connector Absolute Maximum Ratings  
Parameter  
Symbol  
TS,O  
TO  
Min.  
-40  
-40  
0
Max.  
85  
Unit  
°C  
Note  
Storage and Operating Temperature  
Recommended Operating Temperature  
Installation Temperature  
1
1
1
2
85  
70  
0.7  
100  
°C  
°C  
N-m  
OzF-in.  
Tl  
TN  
Nut Torque  
HFBR-4505/4515 Adapter  
Notes:  
1. Storage and Operating Temperatures refer to the ranges over which the connectors can be used when not subjected to mechanical  
stress. Installation Temperature refers to the ranges over which connectors may be installed onto the fiber and over which connectors  
can be connected and disconnected from transmitter and receiver modules.  
2. Recommended nut torque is 0.57 N-m.  
Plastic Optical Fiber Connector Mechanical/Optical Characteristics  
T = -40 to +85°C, Unless Otherwise Specified.  
A
Parameter  
Part Number  
Simplex,  
HFBR-4501/4511  
Symbol Min. Typ.[1] Max. Units Temp. °C Note  
Retention Force,  
Connector to  
Versatile Link  
Transmitters and  
Receivers  
FR-C  
7
3
8
N
+25  
-40 to +85  
2
Simplex Latching,  
HFBR-4503/4513  
Duplex,  
47  
11  
7
4
80  
12  
80  
22  
22  
+25  
-40 to +85  
+25  
-40 to +85  
HFBR-4506  
Duplex Latching,  
HFBR-4516  
Simplex,  
HFBR-4501/4511  
Simplex Latching,  
HFBR-4503/4513  
50  
15  
8.5  
+25  
-40 to +85  
Tensile Force,  
Connector to Cable  
FT  
N
3
8.5  
Duplex, HFBR-4506  
Duplex Latching,  
HFBR-4516  
14  
14  
35  
35  
Adapter Connector  
to Connector Loss  
Retention Force  
HFBR-4505/4515 with  
HFBR-4501/4511  
HFBR-4505/4515 with  
αCC  
FR-B  
FI  
0.7  
7
1.5  
8
2.8  
dB  
N
25  
4, 5  
6
Connector to Adapter HFBR-4501/4511  
Insertion Force,  
Connector to  
Versatile Link  
Transmitters and  
Receivers  
Simplex,  
HFBR-4501/4511  
8
30  
35  
N
Simplex Latching,  
HFBR-4503/4513  
Duplex, HFBR-4506  
16  
13  
22  
46  
51  
Duplex Latching  
HFBR-4516  
Notes:  
1. Typical data are at +25°C.  
2. No perceivable reduction in retention force was observed after 2000 insertions. Retention force of non-latching connectors is lower at  
elevated temperatures. Latching connectors are recommended for applications where a high retention force at high temperatures is  
desired.  
3. For applications where frequent temperature cycling over temperature extremes is expected, please contact Agilent Technologies for  
alternate connectoring techniques.  
4. Minimum and maximum limit for αCC for 0°C to +70°C temperature range. Typical value of αCC is at +25°C.  
5. Factory polish or field polish per recommended procedure.  
6. Destructive insertion force was typically at 178 N (40 lb.).  
5
Step-by-Step Plastic  
Cable Connectoring  
Instructions  
The following step-by-step guide  
describes how to terminate plastic  
fiber optic cable. It is ideal for  
both field and factory installation.  
Connectors can be easily installed  
on cable ends with wire strippers,  
cutters and a crimping tool.  
c) HFBR-4506 Parchment (off-  
white) Duplex Connector  
and HFBR-4526 Duplex  
Crimp Ring  
d) HFBR-4516 Gray Latching  
Duplex Connector and  
HFBR-4526 Duplex Crimp  
Ring  
Step 2  
Place the crimp ring and connec-  
tor over the end of the cable; the  
fiber should protrude about 3 mm  
(0.12 in.) through the end of the  
connector. Carefully position the  
ring so that it is entirely on the  
connector with the rim of the  
crimp ring flush with the connec-  
tor, leaving a small space between  
the crimp ring and the flange.  
Then crimp the ring in place with  
the crimping tool. One crimp tool  
is used for all POF connector  
crimping requirements.  
Step 1  
The zip cord structure of the  
duplex cable permits easy  
Finishing the cable is accom-  
plished with the Agilent  
HFBR-4593 Polishing Kit, consist-  
ing of a Polishing Fixture, 600  
grit abrasive paper and 3 µm pink  
lapping film (3M Company,  
separation of the channels. The  
channels should be separated a  
minimum of 100 mm (4 in) to a  
maximum of 150 mm (6 in) back  
from the ends to permit  
For applications with extreme  
temperature operation or frequent  
temperature cycling, improved  
connector to cable attachment  
can be achieved with the use of an  
RTV (GE Company, RTV-128 or  
Dow Corning 3145-RTV)  
adhesive. The RTV is placed into  
the connector prior to insertion of  
the fiber and the fiber is crimped  
normally. The connector can be  
polished after the RTV has cured  
and is then ready for use.  
OC3-14). The connector can be  
used immediately after polishing.  
connectoring and polishing.  
After cutting the cable to the  
desired length, strip off approxi-  
mately 7 mm (0.3 in.) of the outer  
jacket with the 16 gauge wire  
strippers. Excess webbing on the  
duplex cable may have to be  
trimmed to allow the simplex or  
simplex latching connector to  
slide over the cable.  
Materials needed for plastic fiber  
termination are:  
1. Agilent Plastic Optical Fiber  
Cable (Example: HFBR-  
RUS500, HFBR-RUD500,  
HFBR-EUS500, or HFBR-  
EUD500)  
2. Industrial Razor Blade or Wire  
Cutters  
When using the duplex connector  
and duplex cable, the separated  
duplex cable must be stripped to  
equal lengths on each cable. This  
allows easy and proper seating of  
the cable into the duplex  
3. 16 Gauge Latching Wire  
Strippers (Example: Ideal  
StripmasterTM type 45-092).  
4. HFBR-4597 Crimping Tool  
5. HFBR-4593 Polishing Kit  
Note: By convention, place the  
gray connector on the trans-  
mitter cable end and the blue  
connector on the receiver cable  
end to maintain color coding  
(different color connectors are  
mechanically identical).  
6. One of the following  
connectors:  
connector.  
a) HFBR-4501/4503 Gray  
Simplex/Simplex Latching  
Connector and HFBR-4525  
Simplex Crimp Ring  
b) HFBR-4511/4513 Blue  
Simplex/Simplex Latching  
Connector and HFBR-4525  
Simplex Crimp Ring  
Simplex connector crimp rings  
cannot be used with duplex con-  
nectors and duplex connector  
crimp rings cannot be used  
with simplex connectors because  
of size differences. The simplex  
crimp has a dull luster appear-  
ance; the duplex ring is glossy  
and has a thinner wall.  
6
dot is no longer visible.  
Note: Use of the pink lapping  
film fine polishing step results  
in approximately 2 dB  
improvement in coupling  
performance of either a  
Typically, the polishing fixture  
can be used 10 times; 10 duplex  
connectors or 20 simplex  
connectors, two at a time.  
transmitter-receiver link or a  
bulkhead/splice over a 600 grit  
polish alone. This fine polish is  
comparable to the Agilent  
factory polish. The fine  
polishing step may be omitted  
where an extra 2 dB of optical  
power is not essential, as with  
short link lengths. Proper  
polishing of the tip of the fiber/  
connector face results in a tip  
diameter between 2.5 mm  
(0.098 in.) minimum and 3.2  
mm (0.126 in.) maximum..  
Place the 600 grit abrasive paper  
on a flat smooth surface, pressing  
down on the connector, polish the  
fiber and the connector using a  
figure eight pattern of strokes  
until the connector is flush with  
the bottom of the polishing  
fixture. Wipe the connector and  
fixture with a clean cloth or  
tissue.  
Step 4  
Step 3  
Place the flush connector and  
polishing fixture on the dull side  
of the 3 µm pink lapping film and  
continue to polish the fiber and  
connector for approximately 25  
strokes. The fiber end should be  
flat, smooth and clean.  
Any excess fiber protruding from  
the connector end may be cut off;  
however, the trimmed fiber  
should extend at least 1.5 mm  
(0.06 in) from the connector end.  
HFBR-4593 Polishing Kit  
Insert the connector fully into the  
polishing fixture with the trimmed  
fiber protruding from the bottom  
of the fixture. This plastic polish-  
ing fixture can be used to polish  
two simplex connectors or simplex  
latching connectors simultane-  
ously, or one duplex connector.  
This cable is now ready for use.  
Note: The four dots on the  
bottom of the polishing fixture  
are wear indicators. Replace  
the polishing fixture when any  
7
Ordering Guide for POF Connectors and Accessories  
Plastic Optical Fiber Connectors  
HFBR-4501  
HFBR-4511  
HFBR-4503  
HFBR-4513  
HFBR-4506  
HFBR-4516  
HFBR-4505  
HFBR-4515  
Gray Simplex Connector/Crimp Ring  
Blue Simplex Connector/Crimp Ring  
Gray Simplex Latching Connector with Crimp Ring  
Blue Simplex Latching Connector with Crimp Ring  
Parchment Duplex Connector with Crimp Ring  
Gray Duplex Latching Connector with Crimp Ring  
Gray Adapter (Bulkhead/Feedthrough)  
Blue Adapter (Bulkhead/Feedthrough)  
Plastic Optical Fiber Accessories  
HFBR-4522  
HFBR-4525  
HFBR-4526  
HFBR-4593  
500 HFBR-0500 Products Port Plugs  
1000 Simplex Crimp Rings  
500 Duplex Crimp Rings  
Polishing Kit (one polishing tool, two pieces 600 grit  
abrasive paper, and two pieces 3 µm pink lapping film)  
Plastic Fiber Crimping Tool  
HFBR-4597  
Ordering Guide for POF  
Cable  
For Example:  
HFBR-RUD500 is a Standard  
Attenuation, Unconnectored,  
Duplex, 500 meter cable.  
HFBR-RMD010 is a Standard  
Attenuation, Standard Duplex  
Connectored, Duplex, 10 meter  
cable.  
Cable Length Tolerances:  
The plastic cable length  
tolerances are: +10%/-0%.  
NOTE: By convention, pre-  
connectored simplex POF cables  
have gray and blue colored  
connectors on the opposite ends  
of the same fiber; although  
oppositely colored, the  
connectors are mechanically  
identical. Duplex POF cables with  
duplex connectors use color-  
coded markings on the duplex  
fiber cable to differentiate  
between the channel.  
HFBR-RMD100 is a Standard  
Attenuation, Standard Duplex  
Connectored, Duplex, 100 meter  
cable.  
HFBR-RLS001 is a Standard  
Attenuation, Latching Simplex  
Connectored, Simplex, 1 meter  
cable.  
HFBR-  
Cable Code  
R = Standard Attenuation POF  
E = Extra Low Loss POF  
Length Code (measured from tip of  
connector to tip of connector)  
1-500 meters in 1 meter increments  
e.g. 015 = 15 meters  
1-10 meters in 1 decimeter increments  
e.g. 15D = 1.5 meters  
Connector Code  
U = Unconnectored  
N = Standard Simplex Connectors  
L = Latching Simplex Connectors  
M = Standard Duplex Connectors  
T = Latching Duplex Connectors  
Channel Code  
S = Simplex Cable  
D = Duplex Zipcord Cable  
Note: Not all possible combinations reflect available part numbers. Please contact  
your local Agilent representative for a list of current available cable part numbers.  
Connector Applications  
Attachment to Agilent Versatile Link Fiber Optic Components  
Bulkhead Feedthrough or Panel Mounting for HFBR-4501/4511 Simplex Connectors  
Versatile Link Mechanical Dimensions  
All dimensions in mm (inches).  
All dimensions ± 0.25 mm unless otherwise specified.  
Fiber Optic Cable Dimensions  
Panel Mounting – Bulkhead Feedthrough  
1.0 POF  
(0.039)  
0.230  
HCS  
(0.009)  
HFBR-4505 (Gray)/4515 (Blue) Adapters  
Bulkhead Feedthrough with Two HFBR-4501/  
4511 Connectors  
10  
Versatile Link Mechanical Dimensions, continued  
HFBR-4516 (Parchment) Duplex Latching  
Connector  
HFBR-4506 (Parchment) Duplex Connector  
HFBR-4503 (Gray)/4513 (Blue) Simplex  
Latching Connector  
HFBR-4501 (Gray)/4511 (Blue) Simplex  
Connector  
www.agilent.com/semiconductors  
For product information and a complete list of  
distributors, please go to our web site.  
For technical assistance call:  
Americas/Canada: +1 (800) 235-0312 or  
(408) 654-8675  
Europe: +49 (0) 6441 92460  
China: 10800 650 0017  
Hong Kong: (+65) 6271 2451  
India, Australia, New Zealand: (+65) 6271 2394  
Japan: (+81 3) 3335-8152(Domestic/Interna-  
tional), or 0120-61-1280(Domestic Only)  
Korea: (+65) 6271 2194  
Malaysia, Singapore: (+65) 6271 2054  
Taiwan: (+65) 6271 2654  
Data subject to change.  
Copyright © 2002 Agilent Technologies, Inc.  
Obsoletes 5963-3711E  
April 6, 2002  
5988-3625EN  

相关型号:

HFBR-4503B

Optical Networking Connector, Multi Mode, Simplex
AGILENT

HFBR-4503Z

Plastic Optical Fiber Cable and Accessories for Versatile Link
AVAGO

HFBR-4503Z

Fiber Optic Networking Connector, Multi Mode, Simplex
FOXCONN

HFBR-4505

Plastic Optical Fiber Cable and Accessories for Versatile Link
AGILENT

HFBR-4505

Plastic Optical Fiber Cable and Accessories for Versatile Link Telecommunications switching systems
AVAGO

HFBR-4505Z

Plastic Optical Fiber Cable and Accessories for Versatile Link
AVAGO

HFBR-4505Z

暂无描述
FOXCONN

HFBR-4506

Plastic Optical Fiber Cable and Accessories for Versatile Link
AGILENT

HFBR-4506

Plastic Optical Fiber Cable and Accessories for Versatile Link Telecommunications switching systems
AVAGO

HFBR-4506Z

Plastic Optical Fiber Cable and Accessories for Versatile Link
AVAGO

HFBR-4506Z

Fiber Optic Networking Connector, Multi Mode, Duplex
FOXCONN

HFBR-4511

Plastic Optical Fiber Cable and Accessories for Versatile Link
AGILENT