AMEL5-5SMJZ [AIMTEC]
AC/DC Converter; Product Weight (grams): 43; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-63; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 5; Max Output current (A): 1; Efficiency (%): 76; Max Capacitive load (µF): 4000; Package type: Encapsulated; Mounting: PCB; W (in): 1.13; L (in): 2.12; H (in): 0.75; W (mm): 28.8; L (mm): 53.8; H (mm): 19; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55011 Class B; Case material: Plastic (fl;型号: | AMEL5-5SMJZ |
厂家: | AIMTEC |
描述: | AC/DC Converter; Product Weight (grams): 43; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-63; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 5; Max Output current (A): 1; Efficiency (%): 76; Max Capacitive load (µF): 4000; Package type: Encapsulated; Mounting: PCB; W (in): 1.13; L (in): 2.12; H (in): 0.75; W (mm): 28.8; L (mm): 53.8; H (mm): 19; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55011 Class B; Case material: Plastic (fl PC 输入元件 光电二极管 |
文件: | 总3页 (文件大小:530K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AMEL5-MJZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• High efficiency up to 81%
• No load consumption ≤ 0.3W
• IEC/EN/UL60601, 2xMOPP
• Leakage current <80µA
• Operating Temp: -25 °C to +70 °C
• Input: 85-264VAC, 47-63Hz, or 100-370VDC
• Over current, Over Voltage Protection
Models
Single output
Efficiency
(%)
Maximum
capacitive
Load
(µF)
Output
Voltage
(V)
Output
Current max
(A)
Input Voltage
Input Voltage
(VDC)
Model
(VAC/Hz)
230
VAC
AMEL5-5SMJZ
AMEL5-12SMJZ
AMEL5-15SMJZ
AMEL5-24SMJZ
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
100-370
100-370
100-370
100-370
5
12
15
24
1
4000
820
820
330
76
80
81
81
0.42
0.333
0.23
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
264 VAC
Typical
Maximum
120
Units
mA
mA
A
A
µA
Current (full load)
70
10
20
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
80
2A/250V
0.3
Recommended slow blow type
No load (110/230VAC)
W
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise *
Conditions
Typical
±2
±0.5
±1
Maximum
Units
%
%
%
mV p-p
10-100% load
20MHz Bandwidth
115VAC
50
10
80
100
Hold-up time
ms
230VAC
*Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit.
Isolation Specifications
Parameters
Conditions
Typical
4000
>1000
Rated
Units
VAC
MΩ
Tested I/O voltage
Isolation Resistance
60 sec
General Specifications
Parameters
Switching frequency
Protection class
Conditions
Auto recovery
Typical
140
Class II
Maximum
Units
KHz
Over Current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
Cooling
110 - 280
Zener diode clamp
Continuous, hiccup, Auto recovery
-25 to 70
-25 to +105
% of Iout
See derating curve
°C
°C
°C
95
95
0.02
% /°C
Free air convection
Non condensing
Humidity
% RH
www.aimtec.com
F 052e R10
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL5-MJZ
5 Watt | AC-DC / DC-DC Converter
Case material
Weight
Plastic (flammability to UL 94V-0)
43
g
Dimensions (L x W x H)
MTBF
2.12 x 1.13 x 0.75 inches 53.80 x 28.80 x 19.00mm
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals cULus
Medical Electrical Equipment
IEC\EN\UL 60601-1, 2 x MOPP, CSA-C22.2 No. 601.1-M90
EN55011, class B
IEC 61000-4-2, Contact ±6KV/ Air ±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, ±4KV with the recommended
circuit below
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Standards
Surge Immunity
IEC 61000-4-5, ±1KV, Criteria B, ±2KV/4KV with the recommended
circuit below
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC 61000-4-6, 10 Vrms, Criteria A
IEC 61000-4-8, 10 A/m, Criteria A
IEC 61000-4-11, 0-70%, Criteria B
Dimensions
53.80
(2.12)
Case Temperature
Measurement point
45.72
(1.80)
1
3
1
3
TOP VIEW
10.16
(0.40)
28.80
(1.13)
20.32
(0.80)
TOP VIEW
4
+
4
5
2
2
19.00
(0.75)
DIV: 5.08 (0.2)
Ø 1.5 (Ø 0.06)
Ø 1.00
(0.04)
Pin Out Specifications
Pin
1
2
3
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
4
www.aimtec.com
F 052e R10
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL5-MJZ
5 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
Free Air Convection
100
100
80
70
60
80
75
Safe Operating Area
Input 100-264VAC or
120-370VDC
70
Safe Operating Area
60
40
20
40
20
0
85
(100)
0
264
(370)
100
(120)
70
0
20
40
5560
80
- 25
-
20
100
º C
Ambient Temperature
Input Voltage VAC (VDC)
Typical application circuit
Single Output
FUSE
1A/250V
NTC
3
4
+ Vout
- Vout
AC L
AC L
+
MOV
S14K350
AC
DC
C1
1µF/50V
C2
AC N
AC N
EMC recommended circuit
Single Output
LCM
2.2mH
LDM
4.7µH/2A
FUSE
2A/250V
NTC
+Vout
+Vout
AC L
AC N
CY1
1nF/
400VAC
+
CX
0.1µF/
275VAC
MOV
S14K350
AC
DC
C1
1µF/50V
C2
CY2
1nF/
400VAC
AC N
GND
AC L
- Vout
- Vout
Model
C2
5 Vout
12 & 15 Vout
24 Vout
220 µF / 35V
100 µF / 35V
47 µF / 35V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R10
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only