E SERIESE ELECTROMAGNETIC FLOWMETER  
(SEPARATE TYPE)  
DATA SHEET  
FMF1,2/FMH  
The electromagnetic flowmeter is an instrument to measure  
the volumetric flow rate of liquid simply by applying a mag-  
netic field from the outside utilizing the fact that an electric  
conductor which crosses a magnetic field at a certain velocity  
causes voltage to be induced in proportion to the velocity,  
which is known as Faraday’s law.  
This flowmeter is designed with the latest electronics tech-  
nology, realizing a compact and light-weight structure and  
measurement with high accuracy.  
FEATURES  
1. High accuracy  
When conductivity is above 5 µS/cm, flow rate of liquid  
can be measured regardless of density and viscosity. The  
measurement accuracy is as high as 0.6% of rate.  
2. Free power supply  
The flowmeter operates on power supply 100 to 230V AC,  
50/60Hz.  
• Mounting method :  
3. Grounding electrode  
Mounted via flange insertion type on oppo-  
site (with Guide rings)  
··· 3A to 100A  
Use of the grounding electrode of Hasteroy C in the flow-  
meter allows installation without an earth ring.  
Note 1) Guide ring : A ring-shaped guide used for  
centering the sensor when a wafer type  
is mounted on the piping.  
Note 2) Flange with meter size 3A or 6A can be  
used for 15A.  
or flange mounting  
··· 15A to 300A  
4. Change of settings.  
The setting of various parameters can be changed from  
the outside of the case cover. Application of the supplied  
magnetic stick to the outside glass surface enables the  
setting to change without opening the case cover.  
5. Stable measurement of flow rate  
• Fluid pressure :  
A digital filter for pulsating or noisy flow signal, flow rate  
output low cut, and damping function allows flow rate  
measurement to be stabilized.  
0 to 2000kPa or flange operating pressure,  
whichever is lower.  
• Meter size and measurement range  
6. Self-diagnosis function  
See the following table for the full scale of  
measurable flow rate.  
Since self-diagnosis function is provided for empty detec-  
tion, trouble, and maloperation, the flowmeter can be  
used with safety.  
Min.measurement range Max. measurement range  
Meter size  
[m3/h]  
[m3/h]  
7. Simultaneous display of instantaneous flow and total  
flow 2-stage display with LCD backlight which is visible in  
the dark.  
3A Note 3)  
6A Note 3)  
15A  
0 to 0.012  
0 to 0.06  
0 to 0.3  
0 to 0.24  
0 to 1.2  
0 to 6.0  
25A  
0 to 0.6  
0 to 12.0  
0 to 36.0  
0 to 60.0  
0 to 180.0  
0 to 240.0  
0 to 600.0  
0 to 1080  
0 to 1800  
0 to 2400  
40A  
0 to 1.8  
50A  
0 to 3.0  
80A  
0 to 9.0  
SPECIFICATIONS  
100A  
0 to 12.0  
0 to 30.0  
0 to 54.0  
0 to 90.0  
0 to 120.0  
Detector (Model: FMF)  
150A Note 4)  
200A Note 4)  
250A Note 4)  
300A Note 4)  
• Measurement item :  
General-use industrial water, waste water,  
and other liquids with conductivity of more  
than 5µs/cm.  
Wafer type or flange type  
• Structure :  
Note 3) Meter size 3A and 6A : Wafer type only  
Note 4) Meter size 150A or more : Flange type only  
EDS6-120  
Aug.3, 2001  
Date  
FMF1,2/FMH  
Fluid temperature :  
Fault diagnosis function :  
Various faults can be diagnosed by hard-  
ware check and process check.  
Zero point adjustment :  
–25 to +130˚C (PFA, TFE lining)  
[˚C]  
130  
Zero point is automatically calibrated with  
key operation.  
Low cut :  
0 to 10% FS settable  
50  
0
Momentary output can be cut to 0% at  
flow rate below the set cutoff point.  
Note) Output low cut and total low cut are  
set at the same value.  
-25  
[˚C]  
-20  
10  
25  
60  
0% signal lock :  
Ambient tempertaure  
Display and output can be locked to 0%  
with status input.  
A digital filter is included in the converter  
especially for pulsating or noisy flow sig-  
nals.  
Ambient temperature fluid temperature allowable range  
Material :  
Filter :  
Lining  
Tefron(PFA, TFE)  
Signal electrode  
Earth electrode  
Earth ring Note 2)  
Empty detection :  
Hasteroy C-4 equivalent  
Absence of liquid is detected and status  
signal is outputted only when diameter is  
more than 10A and conductivity is more  
than 20µS/cm.  
Housing case  
Aluminum alloy  
SUS316 equivalent  
Aluminum alloy  
Flange Note 3)  
Case of terminal box  
Flow switch : 0 to 130% FS  
Status signal is outputted by setting high/  
low limit flow.  
Note 1) Materials of fluid wetted parts should be selected in  
consideration of erosion due to measuring fluid. Re-  
fer to the table of material selection on the attached  
sheet.  
Dumping time constant :  
1 to 99.999 sec  
Density setting :  
Available from 0.01 to 5.00g/cm3, and the  
weight of the fluid can also be indicated.  
Note 2) For earth ring attachments, see CODE SYMBOLS.  
Note 3) Flange type only  
Converter case :  
Aluminum alloy  
Wiring connection port :  
G /2 (with water-proof gland)  
Finish color : Silver, Lid ....Beige  
Protection class :  
IP67  
Grounding : D-class grounding (100or less)  
Mass : 4.5kg  
Wiring connection port :  
1
G /2  
Finish color : Silver, Lid ....Beige  
Protection class :  
1
IP67  
Grounding : D-class grounding (100or less)  
Conveter (Model: FMH)  
Mounting method :  
Mounting on the pipe or wall  
Input/output signal :  
Length of exclusive signal cable :  
50m or less  
Current output; 4 to 20mA DC  
Load rasistance 0 to 600Ω  
Pulse output; open-collector  
Capacity; 16 to 30V DC, 0.22A or less  
ON voltage; 2V or less  
Other specifications  
For different materials of the electrode and earth-ring, con-  
tact with Fuji Electric.  
Standard performance  
Max. 5kHz  
Accuracy rating of display and pulse output :  
Status output; open-collector  
Capacity: 16 to 30V DC, 0.22A or less  
ON voltage; 2V or less  
Status input; voltage input  
Capacity: 16 to 30V DC  
Flow velocity  
Accuracy  
0.7m/s or more  
±0.5% of rate  
0.0035  
Qv  
±
100 % of rate  
0.7m/s 0or less  
Qv : Measuring flow velocity  
Internal resistance: 2kΩ  
Accuracy rating of analog output :  
Pulse output :  
Span setting :  
Total pulses are outputted by setting total  
constant. Pulse width 0.1 to 2000ms is  
settable.  
Flow rate full scale(FS) can be set by set-  
ting flow rate unit and flow rate value.  
Display cubic volume; m3, L, mL  
Display time unit ; /d, /h, /min, /s  
Flow velocity  
Accuracy  
0.7m/s or more  
±0.6% of rate  
0.0035  
Qv  
±
100+0.1 % of rate  
0.7m/s 0or less  
Qv : Measuring flow velocity  
Power consumption :  
14VA or less  
Operating condition :  
Flow direction change :  
Flow direction can be reversed in flow di-  
Ambient temperature;  
rection mode.  
–25 to 60˚C (Detector : PFA, TFE lining)  
–20 to 60˚C (Converter)  
Ambient humidity; 95% RH or less (Note)  
Power voltage; 100 to 230V AC +10%,  
-15%  
Power frequency; 50/60Hz  
(Note)  
If ambient humidity exceeds 95% RH, se-  
lect a submersible type in FMB model.  
Flow display :  
Total display :  
Real unit flow display, % display or user  
unit display is possible. Max 6 disits.  
Totaled volume can be displayed by set-  
ting the unit of cubic volume.  
Displayed cubic volume unit ; m3, L, mL  
Totaled value is held when power failure  
occurs.  
2
Length of straight pipe for installing the electromagnetic flowmeter  
The length of the up-stream/down-stream straight pipe of the flowmeter should be long enough to ensure accurate measure-  
ments. See below.  
1-1) Upstream reducer pipe  
2-1) Downstream reducer pipe  
Flowmeter  
Flowmeter  
Flowing direction  
Flowing direction  
5D  
Downstream straight pipe unnecessary  
1-2) Upstream diffuser pipe  
2-2) Downstream diffuser pipe  
Flowmeter  
Flowmeter  
Flowing direction  
Flowing direction  
5D  
Downstream straight pipe unnecessary  
2-3) Various downstream valves  
1-3) Various upstream valves  
Flowmeter  
Flowmeter  
Flowing direction  
Flowing direction  
Note)  
10D  
2
3D  
Note) "5D" with sluice valve fully open  
1-4) Upstream 90° bend  
2-4) Downstream 90° bend  
Flowmeter  
Flowmeter  
Flowing  
direction  
Flowing direction  
2
3D  
5D  
1-5) Upstream T-pipe  
2-5) Downstream T-pipe  
Flowmeter  
Flowmeter  
Flowing  
direction  
Flowing direction  
5D  
2
3D  
Minimum length of straight pipe between up-stream/down-stream joints and flowmeter.  
Note 1) D=diameter of measuring pipe.  
Note 2) Do not put any objects, which affect magnetic field, electromotive force and flow velocity profile, in the measuring pipe.  
Note 3) Use a straight pipe (2D to 3D) on the down-steam side, if the drift to the up-stream side is affected by installing valves,  
etc.  
3
FMF1,2/FMH  
Mounting posture of electromagnetic flowmeter  
The flowmeter can be installed vertically, horizontally, or at other angle. When installing, be sure to observe the following points.  
q The measuring pipe should always fill with fluid which flows in the piping.  
Fluid may not fill up the pipe.  
Air are apt to from.  
Fluid may not  
fill up the pipe.  
Good  
Good  
Pump  
Example of mounting posture  
w The signal electrode should be at a level with the ground. And also signal electrode and ground electrode should always keep  
contact with fluid. If the signal electrode or the ground electrode is upper position against the fluid, correct measurements  
cannot be expected due to air bubbles on the fluid.  
Signal electrode  
Ground electrode  
Ground  
Ground  
< Good >  
< Good >  
Ground electrode  
Signal electrode  
Signal electrode  
Ground  
electrode  
Ground  
Ground  
< No good >  
< No good >  
Position of electrode  
How to connect the grounding cable contacting with measuring liquid.  
Since the electromagnetic flowmeter is provided with a grounding electrode, flow rate of liquid can be measured without an earth  
ring. However, if stray potential exists in a pipeline, the potential in the pipeline may fluctuate.  
In this case, the earth ring (option) of the same material as signal electrode and ground electrode should be mounted on the  
upstream and downstream sides of the flowmeter to connect to the grounding terminal.  
For liquid that contains attachments or deposits, take the liquid contacting ground from the optional earth rings and metallic pipe  
(without lining).  
Grounding connection  
In case of metallic  
pipe without linging  
Without earth ring  
With earth ring  
4
CODE SYMBOLS  
Separate type electromagnetic flowmeter Detector (wafer type)  
1
2
3
4
5
6
7
8
9
10 11 12 13  
14  
FMF 1  
1 - H 0 A 0 -  
Description  
Meter size (5th code)  
S
A
C
D
T
E
F
G
3A  
6A  
15A  
25A  
40A  
50A  
80A  
100A  
Lining material (6th code)  
T
P
TFE (adhesive Tefron) : applied for meter size 15A to 100A  
PFA (mold Tefron) : applied for meter size 3A to 6A  
Earth ring material (7th code)  
0
None  
H
Hasteroy C  
Electrode matertal (9th code)  
Hasteroy C  
H
0
Flange (10th code)  
None  
Guide ring (11th code)  
1
7
For JIS 10K  
For JIS 75M (Meter size 80A, 100A only)  
Wiring connection port size (12th code)  
A
0
G1/2(PF1/2) female screw with water-proof gland  
Application (13th code)  
Standard  
Optional specifications (14th code)  
None  
Stainless tag plate  
Y
A
Note 1) Items with the asterisk mark will be manufactured as order.  
5
FMF1,2/FMH  
Separate type electromagnetic flowmeter Detector (flange type)  
1
2
3
4
5
6
7
8
9
10 11 12 13  
14  
FMF 2  
T
1 - H 1 0 A 0 -  
Description  
Meter size (5th code)  
C
D
T
E
F
15A  
25A  
40A  
50A  
80A  
G
H
J
K
L
100A  
150A  
200A  
250A  
300A  
Lining material (6th code)  
TFE (adhesive Tefron)  
T
Earth ring material (7th code)  
0
None  
H
Hasteroy C  
Electrode matertal (9th code)  
Hasteroy C  
H
1
Flange (10th code)  
For JIS 10K  
Guide ring (11th code)  
None  
0
Wiring connection port size (12th code)  
A
0
G1/2(PF1/2) female screw with water-proof gland  
Application (13th code)  
Standard  
Optional specifications (14th code)  
None  
Stainless tag plate  
Y
A
Note 1) Items with the asterisk mark will be manufactured as order.  
Separate type electromagnetic flowmeter Converter  
1
2
3
4
5
6
7
8
9
10 11 12 13  
FMH 1 N A 1 -  
Y
Description  
Application (4th digit)  
1
Standard  
Power supply (5th digit)  
AC100 230V  
N
Mounting method (6th digit)  
Pipe mount  
Wall mount  
A
B
Wiring lead-in port (7th digit)  
A
G1/2(PF1/2) female, with water-proof gland  
Optional specification (9th digit)  
None  
With parameter setting function  
Y
A
Cable termination (10th digit)  
None  
Y
Cable length (11 to 13th digit)  
0 0 0  
0 1 0  
0 2 0  
0 3 0  
0 4 0  
0 5 0  
Nothing  
10m  
20m  
30m  
40m  
50m  
6
OUTLINE DIAGRAM (Unit: mm)  
(Wafer type detector)  
< Stainless tag >  
Option  
Wiring lead-in port G1/2  
88  
35  
67.5  
20  
Water-proof  
gland  
3A,6A 15A  
25A  
40A  
50A  
80A  
100A  
Meter size  
W1  
69  
75  
62  
191  
2
69  
75  
62  
191  
2
91  
95  
104  
112  
82  
119  
130  
90  
103  
163  
110  
287  
8
133  
190  
130  
327  
9
B
F
73  
H
213  
3.5  
231  
5
247  
5.5  
Mass ( Kg )  
B
W1  
(Flange type detector)  
< Stainless tag >  
Option  
Wiring lead-in port  
67.5  
88  
35  
Water-proof  
gland  
20  
N-øB  
15A 25A 40A 50A 80A 100A  
Meter size  
W1  
W2  
66.5 87 100 116 100 130  
200 200 200 200 200 250  
95 125 140 155 185 210  
C
ø
øD  
øC  
70  
90 105 120 150 175  
N-øB  
4-12 4-15 4-15 4-19 8-19 8-19  
JIS 10K  
flange  
T
14  
52  
18  
70  
20  
20  
20  
22  
øG  
85 100 130 155  
H
191 213 231 247 287 327  
F
62  
3
73  
4
82  
6
90 110 130  
16 17  
Mass ( Kg )  
8
W1-03  
T
(Note) W2 are dimensions after positioning to piping.  
The lining flare sections are not glued before  
positioning to piping  
W2 (Note)  
(There are about 30mm protruding of each side.)  
7
FMF1,2/FMH  
OUTLINE DIAGRAM (Unit: mm)  
1
G /  
Wiring lead-in port  
2
ø80  
67  
35  
Water-proof  
gland  
N-øB  
W1  
T
W2 (Note)  
Meter size  
150A 200A 250A 300A  
< Stainless tag >  
Option  
W1  
W2  
øD  
170  
195  
250  
250  
0
0
0
0
300 -3 350  
450  
500  
-3  
-5  
-5  
280  
240  
330  
290  
400  
355  
445  
400  
øC  
N-øB  
8-23 12-23 12-25 16-25  
JIS 10K  
flange  
T
25  
212  
368  
148  
29  
28  
268  
430  
179  
53  
30  
320  
486  
207  
79  
31  
370  
572  
250  
81  
øG  
H
F
20  
Mass (kg)  
(Note) W2 are dimensions after positioning to piping.  
The lining flare sections are not glued before  
positioning to piping  
(There are about 30mm protruding of each side.)  
8
OUTLINE DIAGRAM (Unit: mm)  
(Pipe mount type converter)  
Mounting pipe  
JIS 2B  
Water-proof gland  
78  
108  
70  
49  
U-bolt M8  
229  
199  
Wiring lead-in  
1
G /  
port  
2
(Wall mount type converter)  
Water-proof gland  
229  
199  
80  
60  
78  
ø7  
Wiring lead-in  
1
G /  
port  
2
ø7  
9
FMF1,2/FMH  
EXTERNAL CONNECTION DIAGRAM  
Shield of flow rate  
signal cable  
Flow rate signal  
Excitation  
Converter<FMH>  
Outer shield  
Detecter<FMF>  
Inner shield  
V9 V8 P7 G2 X2  
+
N
L
M2 M1 2S  
2
1
1S  
3
M2 M1  
2
1
3
SE  
Total pulse  
output  
Power supply  
Special signal cable  
Current output  
Status input  
Status output  
FLOW RATE – FLOW VELOCITY CONVERSION DIAGRAM  
3 4 5 6 810-2  
2
3
4 5 6 810-1  
2
3
4 5 6 8 1  
2
3
4 5 6 8 10  
2
3
4 5 6 8 102  
2
3
4 5 6 8  
L/s  
10  
8
6
5
4
3
2
1
0.8  
0.7  
0.5  
m3/ h  
L/min  
10-2  
2
3
4 5 6 810-1  
4 5 6 8 1  
2
3
4 5 6 8 1  
2
3
4 5 6 8 10  
2
3
4 5 6 8102  
4 5 6 8103  
2
3
4 5 6 8103  
4 5 6 8104  
2
3
2
3
2
3
4 5 6 8 10  
2
3
4 5 6 8102  
Flow rate  
2
3
2
3
2
3
4 5  
SCOPE OF DELIVERY  
HOW TO CONNECT CABLE  
Detecter (mounting bolt and packing should be prepared  
separately).  
1. Press the terminal spring by inserting a minus driver  
(small) through the opening at top.  
Converter ×1 (with metal fixtures for pipe-mount or wall-  
2. Insert terminated cable into the cable lead-in port as  
shown below.  
mount)  
Special signal cable ×1 (length; by specifing)  
3. When the driver is removed, the cable is fixed (connected)  
by the spring force in the terminal.  
Magnetic stick  
Minus driver (small)  
10 15mm  
SPARE PARTS  
Guide rings (note) / for wafer type.  
Note) Not supplied for 80A and 100A JIS 10K.  
Cable  
ITEMS SPECIFIED AT ORDERING  
Note) Cable should be securely fixed with the supplied  
water-proof gland.  
1. Type, specification code.  
2. Flow measurement range and mesurement fluid.  
3. When ordering “with stainless tag plate,” specify Tag No.  
(up to 16 alphanumeric characters) as needed.  
4. When ordering “with parameter setting,” complete and  
send the attached parameter designation table.  
10  
If you want the instrument with certain parameters factory set as you desire, specify them in the following parameter designation  
tables 1 and 2.  
Company :  
Name :  
Sector :  
Telephone No. :  
Measured fluid :  
<Parameter designation table 1>  
Put check marks into which precede items to modify for.  
Standard set value  
Item selection or  
value designation  
Setting item  
Range  
Item to select  
Example  
020.0s  
(Note 1)  
Damping  
5.0s  
1.0 to 99.0s  
.
[s]  
LCD  
1st line  
indication  
Real scale  
indication  
<1st line, 2nd line>  
<Designation of 1st line indication> According to selection of left item,  
Select an item from the following. designate necessary item and value.  
Real scale indication  
Volume unit: mL, L, m3  
Mass unit: g, kg  
q Real scale indication  
Volume unit: mL, L, m3  
Mass unit: g, kg  
Unit: m3/h  
Time unit: /s, /min, /h  
Arbitrary real scale indication Unit factor: 0.00001 to  
9999999  
Time unit: /s, /min, /h  
w Arbitrary real scale unit  
Unit factor: 0.00001 to  
9999999  
Unit name: Arbitrary value  
of 4 characters  
1000000  
*Value converted the units into L  
Unit name:  
None.  
e Percent indication (%)  
Percent indication  
t/h  
1000000  
t
Total real scale indication Volume unit: mL, L, m3  
Mass unit: g, kg  
r Total real scale indication  
Volume unit: mL, L, m3  
Mass unit: g, kg  
Arbitrary total real scale Unit factor: 0.00001 to  
indication  
9999999  
t Arbitrary total real scale unit  
Unit factor: 0.00001 to  
9999999  
Unit name: Arbitrary value  
of 4 charactes  
*Value converted the units into L  
Unit name:  
TAG No. indication  
Bar graph indication  
Non-display  
<Designation of 2nd line indication> According to selection of left item,  
Select an item from the following. designate necessary item and value.  
None  
None  
None  
y TAG No. indication  
u Bar graph indication  
(Percent indication can also  
be indicated simultaneously  
in 1% step)  
LCD  
2nd line  
indication  
Total real scale  
indication  
Real scale indication  
Volume unit: mL, L, m3  
Mass unit: g, kg  
Unit: m3  
i Non-display  
Time unit: /s, /min, /h  
Arbitrary real scale indication Unit factor:0.00001 to  
9999999  
1000000  
t/h  
*Value converted the units into L  
Unit name:  
Percent indication  
None.  
Total real scale indication Volume unit: mL, L, m3  
Mass unit: g, kg  
Arbitrary total real scale Unit factor: 0.00001 to  
indication  
9999999  
Value converted the units into L  
1000000  
t
*
Unit name:  
TAG No. indication  
Bar graph indication  
Non-display  
None  
None  
None  
Range  
By table-1  
(Note 5)  
0.5 to 10 m/s  
converted to flow velocity.  
Volume unit  
Time unit: /s, /min,  
/h, /d  
:
mL, L, m3 Must be designated in 4 significant digits. 100.0  
Value:  
Instantaneous  
output  
low-cut point  
Total  
None.  
0.0%  
0.0% to 10.0%  
FORWARD  
.
None.  
Value:  
%
3.5%  
FORWARD  
/REVERSE (Note4) FORWARD/REVERSE  
FORWARD  
direction  
FORWARD/REVERSE  
Volume unit:  
Total constant 1m3  
(Note 2)  
Value: 0.001 to 1000  
Unit : mL, L, m3  
mL, L, m3  
(Total value  
per pulse)  
Total pulse  
width  
30ms  
0.1 to 2000ms  
None.  
.
[ms]  
50.0[ms]  
(Note 3)  
Filter  
off  
on  
off  
on  
off  
None.  
11  
FMF1,2/FMH  
<Parameter designation table 2>  
Standard set value  
Item selection or  
value designation  
Setting item  
Range  
Item to select  
Example  
(Note 1)  
Empty detection off  
function  
on  
off  
on  
off  
Alarm output value  
3.6mA  
4mA  
24.8mA  
Upper/Lower Upper limit value Upper limit value: 0 to 130%  
Upper limit alarm  
Lower limit alarm  
Alarm output value  
3.6mA  
4mA  
24.8mA  
Upper limit value:  
Upper limit  
value:  
120.0%  
Lower limit  
value:  
limit alarm  
: 130%  
Lower limit value Lower limit value: 0 to 130%  
: 0%  
Upper/Lower limit alarm ꢀꢀꢀꢀ.ꢀꢀꢀ%  
Lower limit value:  
0.0%  
ꢀꢀꢀꢀ.ꢀꢀꢀ%  
Specific gravity 1.000g/cm3  
0.01 5g/cm3  
Up to 16 alphanumerics  
None  
None  
g/cm3  
0.95g/cm3  
F-100  
TAG-NO  
Blank unless  
designated  
STANDARD  
Flow  
STANDARD  
OPPOSITE  
STANDARD  
OPPOSITE  
None  
direction  
(Note 1) Standard set value refers to parameter set value as factory set in case parameter setting is not designated.  
(Note 2) Designate so that the number of total pulse outputs will be below 5kHz at the maximum flow rate (to meet the following equation).  
Range [m3/h] / (total constant [m3] × 3600) 5000  
(Note 3) Designate the total pulse width so as to hold: (Total constant [m3]) × 3600/range [m3/h] total pulse width [ms]/500  
(Note 4) When selecting FORWARD/REVERSE from the total direction, total pulse is only outputted in the FORWARD direction.  
(Note 5) Factory-set range before shipment (unless specified).  
Table-1  
Meter size Range [m3/h] Meter size Range [m3/h] Meter size Range [m3/h]  
3A  
0.05  
0.2  
1.2  
3.5  
40A  
50A  
80A  
100A  
14.0  
14.0  
35.0  
55.0  
150A  
200A  
250A  
300A  
120.0  
220.0  
350.0  
350.0  
6A  
15A  
25A  
(Material selection table of electrode/earth ring)  
Material of  
Measurable liquid  
electrode/earth ring  
Unmeasurable liquid  
SUS316  
Water and waste water, weak acid, weak alkali  
Inorganic acid, organic acid, chloride or alike  
Example: 25% acetic acid or less, hydroiodic acid,  
butyric acid, aqueous ammonia or alike  
Hastelloy C-4 or  
equivalent  
Suitable for intermediate oxidation and reduction  
and can be used for various fields.  
Chloride, high-temperature strong acids  
(nitric acid, hydrochloric acid, sulfuric acid),  
ferric chloride or alike  
Example: Sea water, formic acid, acetic acid, aqueous  
ammonia, normal-temperature nitric acid and sulfuric  
acid or alike  
Titanium  
Tantalum  
Resistant to sea water, most oxidative acids, chloride, Reductive acids such as hydrochloric acid,  
sulfide and alkali.  
sulfuric acid, phosphoric acid, oxalic acid  
Example: Sea water, saline water, aqueous ammonia,  
chlorine water, polyelectrolyte, acetic acid, ferric  
chloride or alike  
Resistant to most chemicals.  
(particularly, strong acids)  
Sodium hydroxide, potassium hydroxide,  
hydroflouric acid, fuming sulfuric acid or  
alike  
Example: Hydrochloric acid, sulfuric acid, nitric acid,  
aqua regia, ferric chloride, hypochlorous acid, sodium  
hypochlorite, PAC (Polyaluminum chloride) or alike  
Platinum-iridium (Pt-Ir)  
Resistant to almost chemicals.  
Aqua regia  
(Note): The electrode/earth ring for E-series electromagnetic flowmeter use Hastelloy C-4 or equivalent.  
If other material except Hastelloy C-4 is required, select a model that uses other material from the separate type  
electromagnetic flowmeter (FMB/C series) of Fuji Electric.  
Caution on Safety  
*Before using this product, be sure to read its instruction manual in advance.  
Head Office  
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan  
http://www.fesys.co.jp/eng  
Sales Div.  
International Sales Dept.  
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan  
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187  
http: //www.fic-net.jp/eng  
Printed in Japan  
Information in this catalog is subject to change without notice.  

相关型号:

EDS6-121A

VORTEX FLOWMETER (Eggs DELTA)
FUJI

EDS6-122A

VORTEX FLOWMETER (DELTA FLOWPET)
FUJI

EDS6-123I

ULTRASONIC FLOWMETER M-Flow ">PW>
FUJI

EDS6-125

OPTICAL DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
FUJI

EDS6-126

OPTICAL DIFFERENTIAL PRESSURE TRANSMITTER REMOTE SEAL TYPE
FUJI

EDS6-128C

EQUALIZING VALVE, OVAL FLANGE
FUJI

EDS6-132F

HYBRID ULTRASONIC FLOWMETER (PULSE">(Pulse Doppler method Transit Time method)
FUJI

EDS6-141D

ULTRASONIC FLOWMETER(2-Path System type)
FUJI

EDS6-33B

FCX SERIES DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-34F

FCX SERIES REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-35D

FCX SERIES FLOW TRANSMITTER
FUJI

EDS6-50I

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE WITH CARRIER RINGS
FUJI