LTP5902IPC-IPRA1C1#PBF [Linear]
LTP5902-IPM - SmartMesh IP Wireless 802.15.4e PCBA Module with Antenna Connector; Pins: 66; Temperature Range: -40°C to 85°C;型号: | LTP5902IPC-IPRA1C1#PBF |
厂家: | Linear |
描述: | LTP5902-IPM - SmartMesh IP Wireless 802.15.4e PCBA Module with Antenna Connector; Pins: 66; Temperature Range: -40°C to 85°C PC 无线 电信 电信集成电路 |
文件: | 总34页 (文件大小:1129K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LTP5901-IPR/LTP5902-IPR
SmartMesh IP Network Manager
2.4GHz 802.15.4e
Wireless Embedded Manager
DescripTion
neTwork FeaTures
n
SmartMesh IP™ wireless sensor networks are self man-
aging, low power internet protocol (IP) networks built
from wireless nodes called motes. The LTP™5901-IPR/
LTP5902-IPR is the IP manager product in the Eterna®*
family of IEEE 802.15.4e printed circuit board assembly
solutions, featuring a highly integrated, low power radio
design by Dust Networks® as well as an ARM Cortex-M3
32-bit microprocessor running Dust’s embedded Smart-
Mesh IP networking software.
Complete Radio Transceiver, Embedded Processor,
and Networking Software for Forming a Self-Healing
Mesh Network
SmartMesh® Networks Incorporate:
n
n
Time Synchronized Network-Wide Scheduling
n
n
n
n
Per Transmission Frequency Hopping
Redundant Spatially Diverse Topologies
Network-Wide Reliability and Power Optimization
NIST Certified Security
n
SmartMesh Networks Deliver:
Based on the IETF 6LoWPAN and IEEE-802.15.4e stan-
dards, the LTP5901/2-IPR runs SmartMesh IP network
management software to monitor and manage network
performance and provide a data ingress/egress point via
a UART interface. The SmartMesh IP software provided
with the LTP5901/2-IPR is fully tested and validated, and
is readily configured via a software application program-
minginterface.WithDust’stime-synchronizedSmartMesh
IP networks, all motes in the network may route, source
or terminate data, while providing many years of battery
powered operation.
n
>99.999% Network Reliability Achieved in the
Most Challenging RF Environments
Sub 50µA Routing Nodes
n
n
Compliant to 6LoWPAN Internet Protocol (IP) and
IEEE 802.15.4e Standards
lTp5901/2-ipr FeaTures
n
Manages Networks of Up to 100 Nodes
n
Sub 1mA Average Current Consumption Enables
Battery Powered Network Management
SmartMesh IP motes deliver a highly flexible network
with proven reliability and low power performance in an
easy-to-integrate platform.
L, LT, LTC, LTM, Linear Technology, Dust, Dust Networks, Eterna, SmartMesh and the
Linear logo are registered trademarks and LTP, SmartMesh IP and the Dust Networks logo are
trademarks of Linear Technology Corporation. All other trademarks are the property of their
respective owners. Protected by U.S. Patents, including 7375594, 7420980, 7529217, 7791419,
7881239, 7898322, 8222965.
n
RF Modular Certification Include USA, Canada, EU,
Japan, Taiwan, Korea, India, Australia and New
Zealand
n
PCB Assembly with Chip Antenna (LTP5901-IPR) or
with MMCX Antenna Connector (LTP5902-IPR)
* Eterna is Dust Networks’ low power radio SoC architecture.
Typical applicaTion
EXPANDED VIEW
LTP5901-IPR
LTP5901/2-IPM
ANTENNA
+
UART
IN
LTC®2379-18 SPI
UART
SENSOR
µCONTROLLER
–
IN
HOST
APPLICATION
59012IPR TA01
MOTE
59012iprfa
1
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Table oF conTenTs
Network Features .......................................... 1
LTP5901/2-IPR Features.................................. 1
Typical Application ........................................ 1
Description.................................................. 1
SmartMesh Network Overview........................... 3
Absolute Maximum Ratings.............................. 4
Pin Configuration .......................................... 4
Order Information.......................................... 5
Recommended Operating Conditions................... 5
DC Characteristics......................................... 5
Radio Specifications ...................................... 6
Radio Receiver Characteristics.......................... 6
Radio Transmitter Characteristics....................... 7
Digital I/O Characteristics ................................ 7
Temperature Sensor Characteristics.................... 7
System Characteristics ................................... 8
UART AC Characteristics.................................. 8
Time AC Characteristics .................................. 9
Radio_INHIBIT AC Characteristics .....................10
Flash AC Characteristics.................................10
Flash SPI Slave AC Characteristics ....................10
External Bus AC Characteristics ........................11
Typical Performance Characteristics ..................14
Pin Functions..............................................19
Operation...................................................22
Power Supply..........................................................23
Supply Monitoring and Reset .................................23
Precision Timing.....................................................23
Application Time Synchronization ..........................23
Time References.....................................................23
Radio ......................................................................24
UARTs.....................................................................24
API UART Protocol .................................................24
CLI UART................................................................25
Autonomous MAC...................................................25
Security ..................................................................25
Temperature Sensor ...............................................25
Radio Inhibit ...........................................................25
Software Installation...............................................26
Flash Data Retention...............................................26
Networking .............................................................26
Applications Information ................................29
Regulatory and Standards Compliance...................29
Soldering Information.............................................29
Related Documentation..................................30
Package Description .....................................31
Revision History ..........................................33
Typical Application .......................................34
Related Parts..............................................34
59012iprfa
2
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
smarTmesh neTwork overview
ASmartMeshnetworkconsistsofaself-formingmulti-hop,
mesh of nodes, known as motes, which collect and relay
data, and a network manager that monitors and manages
network performance and security, and exchanges data
with a host application.
to the network manager in packets called health reports.
The network manager uses health reports to continually
optimizethenetworktomaintain>99.999%datareliability
even in the most challenging RF environments.
The use of TSCH allows SmartMesh devices to sleep in-
between scheduled communications and draw very little
power in this state. Motes are only active in timeslots
where they are scheduled to transmit or receive, typically
resulting in a duty cycle of < 1%. The optimization soft-
ware in the network manager coordinates this schedule
automatically. When combined with the Eterna low power
radio, every mote in a SmartMesh network—even busy
routing ones—can run on batteries for years. By default,
all motes in a network are capable of routing traffic from
other motes, which simplifies installation by avoiding the
complexity of having distinct routers vs non-routing end
nodes. Motesmaybeconfiguredasnon-routingtofurther
reduce that particular mote’s power consumption and to
support a wide variety of network topologies.
SmartMesh networks communicate using a time slotted
channel hopping (TSCH) link layer, pioneered by Dust
Networks. In a TSCH network, all motes in the network
are synchronized to within less than a millisecond. Time
in the network is organized into timeslots, which enables
collision-free packet exchange and per-transmission
channel-hopping. In a SmartMesh network, every device
has one or more parents (e.g. mote 3 has motes 1 and
2 as parents) that provide redundant paths to overcome
communicationsinterruptionduetointerference,physical
obstruction or multi-path fading. If a packet transmission
fails on one path, the next retransmission may try on a
different path and different RF channel.
A network begins to form when the network manager
instructsitsonboardaccesspoint(AP)radiotobeginsend-
ingadvertisements—packetsthatcontaininformationthat
enablesadevice tosynchronize tothenetworkandrequest
tojoin. Thismessageexchangeispartofthesecurityhand-
shakethatestablishesencryptedcommunicationsbetween
the manager or application, and mote. Once motes have
joined the network, they maintain synchronization through
time corrections when a packet is acknowledged.
ALL NODES ARE ROUTERS.
THEY CAN TRANSMIT AND RECEIVE.
THIS NEW NODE CAN JOIN
ANYWHERE BECAUSE ALL
NODES CAN ROUTE.
HOST
APPLICATION
59012IPR SNO02
At the heart of SmartMesh motes and network managers
is the Eterna IEEE 802.15.4e System-on-Chip (SoC), fea-
turing Dust Networks’ highly integrated, low power radio
design, plus an ARM Cortex-M3 32-bit microprocessor
runningSmartMeshnetworkingsoftware.TheSmartMesh
networking software comes fully compiled yet is configu-
rable via a rich set of application programming interfaces
(APIs) which allows a host application to interact with
the network, e.g. to transfer information to a device, to
configure data publishing rates on one or more motes,
or to monitor network state or performance metrics. Data
publishing can be uniform or different for each device,
with motes being able to publish infrequently or faster
NETWORK MANAGER
AP
Mote
1
Mote
2
Mote
3
59012IPR SNO01
An ongoing discovery process ensures that the network
continually discovers new paths as the RF conditions
change. In addition, each mote in the network tracks per-
formance statistics (e.g. quality of used paths, and lists of
potential paths) and periodically sends that information
than once per second as needed.
59012iprfa
3
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
absoluTe maximum raTings
(Notes 1, 2)
Operating Temperature Range
Supply Voltage on VSUPPLY..................................4.20V
Input Voltage on AI_0/1/2/3 Inputs........................1.98V
Voltage on Any Digital I/O Pin .... –0.3V to VSUPPLY + 0.3V
Input RF Level......................................................10dBm
Storage Temperature Range (Note 3)..... –55°C to 105°C
LTP5901I/LPT5902I.............................–40°C to 85°C
CAUTION: This part is sensitive to electrostatic discharge
(ESD). It is very important that proper ESD precautions
be observed when handling the LTP5901/LTP5902-IPR.
pin conFiguraTion
Pin functions shown in italics are currently not supported in software.
1
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
GND
RESERVED
NC
GND
2
NC
3
RADIO_INHIBIT
TIMEn
4
5
6
7
8
9
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
GND
UART_TX
UART_TX_CTSn
UART_TX_RTSn
UART_RX
UART_RX_CTSn
UART_RX_RTSn
GND
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
RESERVED
NC
VSUPPLY
RESERVED
NC
NC
RESETn
TDI
NC
FLASH_P_ENn / EB_IO_LE1
EB_IO_OEn
EB_IO_WEn
RESERVED / UARTC1_RX
RESERVED / UARTC1_TX
EB_IO_CS0n
EB_DATA_5
EB_DATA_2
EB_DATA_3
GND
TDO
TMS
TCK
GND
RESERVED
RESERVED
RESERVED
RESERVED
EB_DATA_7
EB_DATA_6
EB_DATA_4
EB_DATA_0
NC
EB_ADDR_0
EB_ADDR_1
IPCS_SSn
EB_IO_LE2
GND
GND
31 32 33
34 35 36
PC PACKAGE
66-LEAD PCB
59012iprfa
4
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
orDer inFormaTion
LEAD FREE FINISH†
PART MARKING*
PACKAGE DESCRIPTION
TEMPERATURE RANGE
LTP5901IPC-IPMA#PBF
LTP5902IPC-IPMA#PBF
LTP5901IPC-IPMA#PBF
LTP5902IPC-IPMA#PBF
66-Lead (42mm × 24mm × 5.5mm) PCB with Chip Antenna
–40°C to 85°C
–40°C to 85°C
66-Lead (37.5mm × 24mm × 5.5mm) PCB with MMCX
Connector
†This product ships with the flash erased at the time of order. OEMs will need to program devices during development and manufacturing.
For legacy part numbers and ordering information go to: www.linear.com/ltp5901-ipr#orderinfo or www.linear.com/ltp5902-ipr#orderinfo
For more information on lead free part marking, go to: http://www.linear.com/leadfree/
*The temperature grade is identified by a label on the shipping container.
recommenDeD operaTing conDiTions
The l denotes the specifications which apply over
the full operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
SYMBOL PARAMETER
VSUPPLY Supply Voltage
Supply Noise
CONDITIONS
MIN
TYP
MAX
3.76
250
90
UNITS
V
l
l
l
Including Noise and Load Regulation
50Hz to 2MHz
2.1
mV
Operating Relative Humidity
Non-Condensing
10
–8
% RH
l
Temperature Ramp Rate While Operating in
Network
8
°C/min
Dc characTerisTics
The l denotes the specifications which apply over the full operating temperature range,
otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
OPERATION/STATE
CONDITIONS
MIN
TYP
MAX
UNITS
Power-On Reset
During Power-On Reset, Maximum 750µs + VSUPPLY Rise Time from 1V to
1.9V
12
mA
Doze
RAM on, ARM Cortex-M3, Flash, Radio, and Peripherals Off, All Data and
State Retained, 32.768kHz Reference Active
1.2
0.8
20
µA
µA
Deep Sleep
RAM on, ARM Cortex-M3, Flash, Radio, and Peripherals Off, All Data and
State Retained, 32.768kHz Reference Inactive
In-Circuit Programming
RESETn and FLASH_P_ENn Asserted, IPCS_SCK at 8MHz
mA
Peak Operating Current
8dBm
0dBm
System Operating at 14.7MHz, Radio Transmitting, During Flash Write.
Maximum Duration 4.33 ms.
30
26
mA
mA
Active
ARM Cortex-M3, RAM and Flash Operating, Radio and All Other Peripherals
Off. Clock Frequency of CPU and Peripherals Set to 7.3728MHz, VCORE =
1.2V
1.3
mA
Flash Write
Flash Erase
Single Bank Flash Write
3.7
2.5
mA
mA
Single Bank Page or Mass Erase
Radio Tx
0dBm
8dBm
Current with Autonomous MAC Managing Radio Operation, CPU Inactive.
Clock Frequency of CPU and Peripherals Set to 7.3728MHz.
5.4
9.7
mA
mA
Radio Rx
Current with Autonomous MAC Managing Radio Operation, CPU Inactive.
Clock Frequency of CPU and Peripherals Set to 7.3728MHz.
4.5
mA
59012iprfa
5
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
raDio speciFicaTions The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
l
l
l
l
l
Frequency Band
2.4000
2.4835
GHz
Number of Channels
Channel Separation
Channel Center Frequency
Raw Data Rate
15
5
2405 + 5 • (k-11)
250
MHz
MHz
kbps
V
Where k = 11 to 25, as Defined by IEEE.802.15.4
Antenna Pin ESD Protection HBM Per JEDEC JESD22-A114F (Note 2)
Range 25°C, 50% RH, +2dBi Omni-Directional Antenna, Antenna 2m Above
Ground
6000
Indoor
100
300
1200
m
m
m
Outdoor
Free Space
raDio receiver characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
PARAMETER
CONDITIONS
MIN
TYP
–93
–95
0
MAX
UNITS
dBm
dBm
dBm
Receiver Sensitivity
Receiver Sensitivity
Saturation
Packet Error Rate (PER) = 1% (Note 5)
PER = 50%
Maximum Input Level the Receiver Will
Properly Receive Packets
Adjacent Channel Rejection Desired Signal at –82dBm, Adjacent Modulated Channel 5MHz
(High Side) Above the Desired Signal, PER = 1% (Note 5)
22
19
40
36
42
–6
dBc
dBc
dBc
dBc
dBc
dBc
Adjacent Channel Rejection Desired Signal at –82dBm, Adjacent Modulated Channel 5MHz
(Low Side) Below the Desired Signal, PER = 1% (Note 5)
Alternate Channel Rejection Desired Signal at –82dBm, Alternate Modulated Channel 10MHz
(High Side) Above the Desired Signal, PER = 1% (Note 5)
Alternate Channel Rejection Desired Signal at –82dBm, Alternate Modulated Channel 10MHz
(Low Side)
Below the Desired Signal, PER = 1% (Note 5)
Second Alternate Channel
Rejection
Desired Signal at –82dBm, Second Alternate Modulated Channel
Either 15MHz Above or Below, PER = 1% (Note 5)
Co-Channel Rejection
Desired Signal at –82dBm, Undesired Signal is an 802.15.4
Modulated Signal at the Same Frequency, PER = 1%
LO Feed Through
–55
50
dBm
ppm
Frequency Error Tolerance
(Note 6)
Symbol Error Tolerance
50
ppm
dBm
Received Signal Strength
Indicator (RSSI) Input
Range
–90 to -10
RSSI Accuracy
6
1
dB
dB
RSSI Resolution
59012iprfa
6
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
raDio TransmiTTer characTerisTics The l denotes the specifications which apply over the
full operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Output Power
High Calibrated Setting
Low Calibrated Setting
Delivered to a 50Ω Load
8
0
dBm
dBm
Spurious Emissions
Conducted Measurement with a 50Ω Single-Ended
Load, 8dBm Output Power. All Measurements Made
with Max Hold.
30MHz to 1000MHz
R
BW
R
BW
R
BW
R
BW
R
BW
= 120kHz, V = 100Hz
< –70
–45
dBm
dBm
dBm
dBm
dBc
BW
1GHz to 12.75GHz
= 1MHz, V = 3MHz
BW
2.4GHz ISM Upper Band Edge (Peak)
2.4GHz ISM Upper Band Edge (Average)
2.4GHz ISM Lower Band Edge
= 1MHz, V = 3MHz
–37
BW
= 1MHz, V = 10Hz
–49
–45
BW
= 100kHz, V = 100kHz
BW
Harmonic Emissions
2nd Harmonic
Conducted Measurement Delivered to a 50Ω Load,
Resolution Bandwidth = 1MHz, Video Bandwidth =
1MHz.
–50
–45
dBm
dBm
3rd Harmonic
DigiTal i/o characTerisTics The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS (Note 7)
MIN
TYP
MAX
UNITS
l
l
V
V
Low Level Input Voltage
High Level Input Voltage
–0.3
0.6
V
V
IL
(Note 8)
VSUPPLY
– 0.3
VSUPPLY
+ 0.3
IH
l
l
V
V
Low Level Output Voltage
High Level Output Voltage
Type 1, I
Type 1, I
= 1.2mA
0.4
V
V
OL
OL(MAX)
OH(MAX)
= –0.8mA
VSUPPLY
– 0.3
VSUPPLY
+ 0.3
OH
l
l
V
V
Low Level Output Voltage
High Level Output Voltage
Type 2, Low Drive, I
Type 2, Low Drive, I
= 2.2mA
0.4
V
V
OL
OL(MAX)
OH(MAX)
= –1.6mA
VSUPPLY
– 0.3
VSUPPLY
+ 0.3
OH
l
l
V
V
Low Level Output Voltage
High Level Output Voltage
Type 2, High Drive, I
Type 2, High Drive, I
= 4.5mA
0.4
V
V
OL
OL(MAX)
OH(MAX)
= –3.2mA
VSUPPLY
– 0.3
VSUPPLY
+ 0.3
OH
Input Leakage Current
Input Driven to VSUPPLY or GND
50
50
nA
Pull-Up/Pull-Down Resistance
kΩ
TemperaTure sensor characTerisTics The l denotes the specifications which apply over
the full operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
PARAMETER
Offset
CONDITIONS
MIN
TYP
MAX
UNITS
°C
Temperature Offset Error at 25°C
0.25
0.033
Slope Error
°C/°C
59012iprfa
7
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
sysTem characTerisTics The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted.
SYMBOL PARAMETER
Doze to Active State Transmit
CONDITIONS (Note 7)
MIN
TYP
5
MAX
UNITS
µs
Doze to Radio Tx or Rx
1.2
4
ms
Q
Q
Charge to Sample RF Channel RSSI
Charge Consumed Starting from Doze State
and Completing an RSSI Measurement
µC
CCA
l
l
l
l
l
Largest Atomic Charge Operation
RESETn Pulse Width
Flash Erase, 21ms Max Duration
200
µC
µs
µF
µH
MAX
125
Total Capacitance
Note 12
Note 12
6
3
Total Inductance
Number of Nodes in Network (Note 12)
Without external SRAM
With external SRAM
32
100
Motes
Motes
l
Network Upstream Throughput (Note 12)
Without external SRAM
With external SRAM
24
36
Pkts/s
Pkts/s
uarT ac characTerisTics The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS (Note 7)
MIN
TYP
MAX
UNITS
l
Permitted Rx Baud Rate Error
Both Application Programming Interface
(API) and Command Line Interface (CLI)
UARTs
–2
2
%
l
l
Generated Tx Baud Rate Error
Both API and CLI UARTs
–1
0
1
2
%
t
Assertion of UART_RX_RTSn to Assertion of
UART_RX_CTSn, or Negation of UART_RX_
RTSn to Negation of UART_RX_CTSn
ms
RX_RTS to RX_CTS
l
l
t
t
Assertion of UART_RX_CTSn to Start of Byte
0
0
20
22
ms
ms
RX_CTS to RX
End of Packet (End of the Last Stop Bit) to
Negation of UART_RX_RTSn
EOP to RX_RTS
l
t
t
t
t
Assertion of UART_TX_RTSn to Assertion of
UART_TX_CTSn
0
2
0
0
22
ms
BEG_TX_RTS to TX_CTS
END_TX_CTS to TX_RTS
TX_CTS to TX
Negation of UART_TX_CTSn to Negation of
UART_TX_RTSn
Bit
Period
l
l
Assertion of UART_TX_CTSn to Start of Byte
2
1
Bit
Period
End of Packet (End of the Last Stop Bit) to
Negation of UART_TX_RTSn
Bit
Period
EOP to TX_RTS
l
l
l
t
t
t
Receive Inter-Byte Delay
Receive Inter-Packet Delay
Transmit Inter-Packet Delay
100
ms
ms
RX_INTERBYTE
20
1
RX_INTERPACKET
TX_INTERPACKET
Bit
Period
l
t
Start of Byte to Negation of UART_TX_CTSn
0
µs
TX to TX_CTS
59012iprfa
8
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
uarT ac characTerisTics The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
t
EOP TO RX_RTS
t
RX_INTERPACKET
UART_RX_RTSn
UART_RX_CTSn
UART_RX
t
RX_RTS TO RX_CTS
t
RX_RTS TO RX_CTS
t
RX_CTS TO RX
t
RX_INTERBYTE
BYTE 0
BYTE 1
t
EOP TO TX_RTS
t
TX_INTERPACKET
UART_TX_RTSn
t
t
END_TX_CTS TO TX_RTS
TX_RTS TO TX_CTS
t
END_TX_RTS TO TX_CTS
t
TX TO TX_CTS
UART_TX_CTSn
UART_TX
t
TX_CTS TO TX
BYTE 0
BYTE 1
59012IPR F01
Figure 1. API UART Timing
Time ac characTerisTics The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS (Note 7)
MIN
125
0
TYP
MAX
UNITS
µs
l
l
t
t
TIMEn Signal Strobe Width
STROBE
Delay from Rising Edge of TIMEn to the Start of
Time Packet on API UART
100
ms
RESPONSE
l
t
Delay from End of Time Packet on API UART to
Falling Edge of Subsequent TIMEn
0
ns
TIME_HOLD
l
l
Timestamp Resolution (Note 9)
1
5
µs
µs
Network-Wide Time Accuracy (Note 10)
t
STROBE
t
TIME_HOLD
TIMEn
t
RESPONSE
UART_TX
TIME INDICATION PAYLOAD
59012IPR F02
Figure 2. Timestamp Timing
59012iprfa
9
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
raDio_inhibiT ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS (Note 7)
MIN
TYP
MAX
UNITS
l
l
t
Delay from Rising Edge of RADIO_
INHIBIT to Radio Disabled
20
ms
RADIO_OFF
t
Maximum RADIO_INHIBIT Strobe Width
2
s
RADIO_INHIBIT_STROBE
t
RADIO_INHIBIT_STROBE
RADIO_INHIBIT
t
RADIO_OFF
RADIO STATE
ACTIVE/OFF
OFF
ACTIVE/OFF
59012IPR F03
Figure 3. RADIO_INHIBIT Timing
Flash ac characTerisTics The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS (Note 7)
MIN
TYP
MAX
21
UNITS
ms
l
l
l
t
t
t
Time to Write a 32-Bit Word (Note 11)
Time to Erase a 2k Byte Page (Note 11)
Time to Erase 256k Byte Flash Bank (Note 11)
Data Retention
WRITE
21
ms
PAGE_ERASE
MASS_ERASE
21
ms
25°C
85°C
105°C
100
20
8
Years
Years
Years
Flash spi slave ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS (Note 7)
MIN
TYP
MAX
UNITS
l
l
l
t
t
t
Setup from Assertion of FLASH_P_ENn to
Assertion of RESETn
0
ns
FP_EN_to_RESET
Delay from the Assertion RESETn to the First
Falling Edge of IPCS_SSn
125
10
µs
µs
FP_ENTER
Delay from the Completion of the Last Flash SPI
Slave Transaction to the Negation of RESETn
and FLASH_P_ENn
FP_EXIT
l
t
IPCS_SSn Setup to the Leading Edge of
IPCS_SCK
15
ns
SSS
l
l
l
l
l
l
t
t
t
t
t
t
IPCS_SSn Hold from Trailing Edge of IPCS_SCK
IPCS_SCK Period
15
300
15
5
ns
ns
ns
ns
ns
ns
SSH
CK
IPCS_MOSI Data Setup
DIS
DIH
DOV
OFF
IPCS_MOSI Data Hold
IPCS_MISO Data Valid
3
IPCS_MISO Data Three-State
0
30
59012iprfa
10
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Flash spi slave ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
t
FP_EN_TO_RESET
FLASH_P_ENn
RESETn
t
t
FP_EXIT
FP_ENTER
t
t
SSH
SSS
IPCS_SSn
IPCS_SCK
t
CK
t
DIS
t
DIH
IPCS_MOSI
59012IPR F04
Figure 4. Flash Programming Interface Timing
exTernal bus ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
l
l
t
EB_IO_LE0, EB_IO_LE1, EB_IO_LE2 Pulse
Width
100
ns
LEPW
t
EB_DATA_[7:0] Address Hold from the
Rising Edge of EB_IO_LE0, EB_IO_LE1, and
EB_IO_LE2
EB_DATA_[7:0] During Address
Phase
90
90
ns
ns
AH
l
t
EB_ADDR_[1:0] Address Valid Until
EB_DATA_[7:0] Data Latched
AV_to_DL
l
l
l
t
t
t
EB_CS0n Asserted Until EB_OEn Asserted
EB_CS0n Asserted
150
100
50
ns
ns
ns
CSn_to_OEn
CSn
EB_ADDR_[1:0], EB_IO_WEn Setup to
EB_CSn Asserted
SU_to_CSn
l
t
EB_ADDR_[1:0], EB_IO_WEn Hold from
EB_CSn Negated
50
ns
H_from_CSn
59012iprfa
11
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
exTernal bus ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
t
LEPW
EB_IO_LE0
EB_IO_LE1
t
LEPW
t
LEPW
EB_IO_LE2
EB_DATA_[7:0]
EB_ADDR_[1:0]
t
t
t
AH
AH
AH
X
A[25:18] A[17:10] A[9:2] D[31:24] D[23:16] D[7:0] D[15:8]
X
t
AV_to_DL
XX
11
10
01
00
t
CSn_OFF
EB_IO_CS0n
EB_IO_OEn
t
CSn_to_OEn
59012IPR F05
Figure 5. External Bus Read Timing
t
LEPW
EB_IO_LE0
t
LEPW
EB_IO_LE1
t
LEPW
EB_IO_LE2
EB_DATA_[7:0]
EB_ADDR_[1:0]
t
t
t
AH
AH
AH
X
A[25:18] A[17:10] A[9:2]
D[31:24]
11
D[23:16]
10
D[7:0]
D[15:8]
01
X
XX
00
00
t
SU_to_CSn
t
H_from_CSn
EB_IO_WEn
EB_IO_CS0n
t
CSn
t
CSn_OFF
59012IPR F06
Figure 6. External Bus Write Timing
59012iprfa
12
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
exTernal bus ac characTerisTics The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12)
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 6: IEEE Std. 802.15.4-2006 requires transmitters to maintain a
frequency tolerance of better than 40ppm.
Note 7: Per pin I/O types are provided in the Pin Functions section.
Note 8: V maximum voltage input must respect the VSUPPLY maximum
IH
Note 2: ESD (electrostatic discharge) sensitive device. ESD protection
devices are used extensively internal to Eterna. However, high electrostatic
discharge can damage or degrade the device. Use proper ESD handling
precautions.
Note 3: Extended storage at high temperature is discouraged, as this
negatively affects the data retention of Eterna’s calibration data. See
FLASH Data Retention section for details.
voltage specification.
Note 9: See the SmartMesh IP Manager API Guide for the time indication
notification definition.
Note 10: Network time accuracy is a statistical measure and varies over
the temperature range, reporting rate and the location of the device relative
to the manager in the network. See Typical Performance Characteristics
section for a more detailed description.
Note 4: Actual RF range is subject to a number of installation-specific
variables including, but not restricted to ambient temperature, relative
humidity, presence of active interference sources, line-of-sight obstacles,
and near-presence of objects (for example, trees, walls, signage, and so
on) that may induce multipath fading. As a result, range varies.
Note 11: Code execution from flash banks being written or erased is
suspended until completion of the flash operation.
Note 12: Guaranteed by design. Not production tested.
Note 5: As specified by IEEE Std. 802.15.4-2006: Wireless Medium
Access Control (MAC) and Physical Layer (PHY) specifications for Low-
Rate Wireless Personal Area Networks (LR-WPANs) http://standards.ieee.
org/findstds/standard/802.15.4-2011.html.
59012iprfa
13
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Typical perFormance characTerisTics
2.0
1.8
1.6
1.4
1.2
1.0
In mesh networks data can propagate from the manager
to the nodes, downstream, or from the motes to the man-
ager, upstream, via a sequence of transmissions from one
device to the next. As shown in Figure 8, data originating
from mote P1 may propagate to the manager directly or
through P2. As mote P1 may directly communicate with
the manager, mote P1 is referred to as a 1-hop mote. Data
originatingfrommoteD1,mustpropagatethroughatleast
one other mote, P2 or P1, and as a result is referred to as
a 2-hop mote. The fewest number of hops from a mote to
the manager determines the hop depth.
0.8
0.6
0.4
0.2
0
0
30
5
10
15
20
25
PACKET RATE (PACKETS/s)
59012IPR F07a
As described in the Application Time Synchronization
section,Eternaprovidestwomechanismsforapplications
to maintain a time base across a network. The synchro-
nization performance plots that follow were generated
using the more precise TIMEn input. Publishing rate is
the rate a mote application sends upstream data. Syn-
chronization improves as the publishing rate increases.
Baseline synchronization performance is provided for a
network operating with a publishing rate of zero. Actual
performance for applications in network will improve
as publishing rates increase. All synchronization testing
was performed with the 1-hop mote inside a temperature
chamber. Timing errors due to temperature changes and
temperature differences both between the manager and
this mote and between this mote and its descendents
therefore propagated down through the network. The
synchronization of the 3-hop and 5-hop motes to the
manager was thus affected by the temperature ramps
even though they were at room temperature. For 2°C/
minute testing the temperature chamber was cycled
between –40°C and 85°C at this rate for 24 hours. For
8°C/minutetesting,thetemperaturechamberwasrapidly
cycled between 85°C and 45°C for eight hours, followed
by rapid cycling between –5°C and 45°C for eight hours,
and lastly, rapid cycling between –40°C and 15°C for
eight hours.
Figure 7a. Supply Current vs Packet Rate
2.5
2.0
1.5
5 HOPS
4 HOPS
3 HOPS
2 HOPS
1 Hop
1.0
0.5
0
0
30
5
10
15
20
25
REPORTING INTERVAL (s)
59012IPR F07b
Figure 7b. Packet Latency vs Reporting Interval
MANAGER
P1
P2
1 HOP
P3
2 HOP
D1
3 HOP
D2
5800IPM F08
Figure 8. Example Network Graph
59012iprfa
14
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Typical perFormance characTerisTics
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
1 Hop, Room Temperature
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
3 Hops, Room Temperature
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
5 Hops, Room Temperature
30
60
14
12
10
8
µ = –0.2
σ = 1.7
N = 89699
µ = 0.0
µ = –0.2
σ = 3.6
N = 89698
σ = 0.9
25
20
15
10
N = 89700
50
40
30
20
6
4
5
0
10
0
2
0
–30 –20
0
10 20 30
–40
40
40
40
–30 –20
0
10 20 30
–10
–30 –20
0
10 20 30
–40
40
–40
40
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G02
59012IPR G01
59012IPR G03
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
1 Hop, 2°C/Min.
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
3 Hops, 2°C/Min.
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
5 Hops, 2°C/Min.
20
15
10
5
14
12
10
8
7
6
5
4
3
2
1
0
µ = 1.5
µ = 0.9
µ = 1.0
σ = 3.3
σ = 3.9
σ = 7.7
N = 93812
N = 93846
N = 93845
6
4
2
0
0
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–40
40
–40
–40
40
–10
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G04
59012IPR G05
59012IPR G06
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
1 Hop, 8°C/Min.
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
3 Hops, 8°C/Min.
TIMEn Synchronization Error
0 Packet/s Publishing Rate,
5 Hops, 8°C/Min.
12
10
8
14
12
7
6
µ = 3.6
µ = 1.1
µ = 1.0
σ = 5.0
σ = 3.8
σ = 7.4
N = 88144
N = 88179
N = 88178
10
8
5
4
3
6
6
4
4
2
0
2
1
0
2
0
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–40
40
–40
–40
40
–10
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G07
59012IPR G08
59012IPR G09
59012iprfa
15
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Typical perFormance characTerisTics
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
1 Hop, Room Temperature
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
3 Hops, Room Temperature
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
5 Hops, Room Temperature
60
50
40
30
60
50
40
30
50
40
30
20
10
0
µ = 0.0
µ = –0.2
σ = 1.2
µ = –0.2
σ = 1.2
σ = 1.2
N = 22753
N = 17008
N = 17007
20
10
0
20
10
00
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–40
40
40
40
–40
40
40
40
–40
40
40
40
–10
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G10
59012IPR G11
59012IPR G12
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
1 Hop, 2°C/Min.
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
3 Hops, 2°C/Min.
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
5 Hops, 2°C/Min.
35
30
25
20
35
30
25
20
15
10
5
45
40
35
30
25
20
15
10
5
µ = 0.5
µ = 0.1
µ = 0.1
σ = 1.9
σ = 1.5
σ = 1.5
N = 85860
N = 85858
N = 85855
15
10
5
0
0
0
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–40
–40
–40
–10
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G13
59012IPR G13
59012IPR G15
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
1 Hop, 8°C/Min.
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
3 Hops, 8°C/Min.
TIMEn Synchronization Error
1 Packet/s Publishing Rate,
5 Hops, 8°C/Min.
60
50
40
30
60
50
40
30
50
40
30
20
10
0
µ = 0.2
µ = 0.0
µ = –1.0
σ = 1.3
N = 33929
σ = 1.4
σ = 1.3
N = 33932
N = 33930
20
10
0
20
10
0
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–30 –20
0
10 20 30
–40
–40
–40
–10
–10
–10
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
SYNCHRONIZATION ERROR (µs)
59012IPR G16
59012IPR G17
59012IPR G18
59012iprfa
16
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Typical perFormance characTerisTics
As described in the SmartMesh Network Overview sec-
tion, devices in network spend the vast majority of their
time inactive in their lowest power state (Doze). On a
synchronous schedule a mote will wake to communicate
with another mote. Regularly occurring sequences which
wake, perform a significant function and return to sleep
are considered atomic. These operations are considered
atomic as the sequence of events can not be separated
into smaller events while performing a useful function.
For example, transmission of a packet over the radio is an
atomicoperation.Atomicoperationsmaybecharacterized
in either charge or energy. In a time slot where a mote
successfully sends a packet, an atomic transmit includes
setuppriortosendingthemessage,sendingthemessage,
receiving the acknowledgment and the post processing
needed as a result of the message being sent. Similarly
in a time slot when a mote successfully receives a packet,
an atomic receive includes setup prior to listening, listen-
ing until the start of the packet transition, receiving the
packet, sending the acknowledge and the post processing
required due to the arrival of the packet.
To ensure reliability each mote in the network is provided
multiple time slots for each packet it nominally will send
and forward. The time slots are assigned to communicate
upstreamwithatleasttwodifferentmotes.Whencombined
with frequency hopping this provides temporal, spatial
and spectral redundancy. Given this approach a mote will
often listen for a message that it will never receive, since
the time slot is not being used by the transmitting mote.
It has already successfully transmitted the packet. Since
typicallythreetimeslotsarescheduledforeveryonepacket
to be sent or forwarded, motes will perform more of these
atomic idle listens than atomic transmit or atomic receive
sequences. Examples of transmit, receive and idle listen
atomic operations are shown below.
59012iprfa
17
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
Typical perFormance characTerisTics
Atomic Operation—Maximum Length Transmit with Acknowledge, 7.25ms Time Slot (54.5µC Total Charge at 3.6V)
Atomic Operation—Maximum Length Receive with Acknowledge, 7.25ms Time Slot (32.6µC Total Charge at 3.6V)
Atomic Operation—Idle Listen, 7.25ms Time Slot (6.4µC Total Charge at 3.6V)
Figure 9.
59012iprfa
18
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
pin FuncTions Pin functions shown in italics are currently not supported in software.
The following table organizes the pins by functional
groups. For those I/O with multiple functions the alternate
functions are shown on the second and third line in their
respective row. The No column provides the pin number.
The second column lists the function. The Type column
lists the I/O type. The I/O column lists the direction of the
signal relative to Eterna. The Pull column shows which
signals have a fixed passive pull-up or pull-down. The
Description column provides a brief signal description.
NO POWER SUPPLY
GND
TYPE
Power
Power
Power
Power
Power
Power
Power
Power
Power
Power
I/O
-
PULL DESCRIPTION
1
-
-
-
-
-
-
-
-
-
-
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Ground Connection
Power Supply Input to Eterna
11 GND
20 GND
30 GND
34 GND
37 GND
42 GND
56 GND
66 GND
55 VSUPPLY
-
-
-
-
-
-
-
-
-
NO RADIO
TYPE
I/O
PULL DESCRIPTION
64 RADIO_INHIBIT
1 (Note 13)
Radio Inhibit
4
5
6
-
GPIO17
GPIO18
GPIO19
ANTENNA
1
1
I/O
I/O
I/O
N/A
-
-
-
-
General Purpose Digital I/O
General Purpose Digital I/O
1
General Purpose Digital I/O
N/A
Chip Antenna (LTP5901) or MMCX Connector (LPT5902)
NO ANALOG
TYPE
I/O
PULL DESCRIPTION
7
8
9
AI_2
AI_1
AI_3
Analog
Analog
Analog
Analog
I
I
I
I
-
-
-
-
Analog Input 2
Analog Input 1
Analog Input 3
Analog Input 0
10 AI_0
NO RESET
TYPE
I/O
PULL DESCRIPTION
15 RESETn
1
I
UP
Reset Input, Active Low
NO JTAG
16 TDI
TYPE
I/O
PULL DESCRIPTION
1
1
1
1
I
O
I
UP
-
JTAG Test Data In
17 TDO
18 TMS
19 TCK
JTAG Test Data Out
JTAG Test Mode Select
UP
I
DOWN JTAG Test Clock
59012iprfa
19
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
pin FuncTions Pin functions shown in italics are currently not supported in software.
NO SPECIAL PURPOSE
TYPE
I/O
PULL DESCRIPTION
63 TIMEn
1 (Note 13)
I
-
Time Capture Request, Active Low
NO CLI AND EXTERNAL MEMORY
25 EB_DATA_7
TYPE
I/O
I/O
I/O
I/O
I/O
PULL DESCRIPTION
1
1
1
1
2
-
-
-
-
-
External Bus Data Bit 7
26 EB_DATA_6
External Bus Data Bit 6
External Bus Data Bit 4
External Bus Data Bit 0
27 EB_DATA_4
28 EB_DATA_0
31 UARTC0_TX
EB_IO_LE0
O
O
CLI UART 0 Transmit
External Bus I/O Latch Enable 0 for External Address Bits A[25:18]
32 UARTC0_RX
EB_DATA_1
1
I
-
CLI UART 0 Receive
External Bus Data Bit 1
I/O
38 EB_IO_LE2
40 EB_ADDR_1
41 EB_ADDR_0
43 EB_DATA_3
44 EB_DATA_2
45 EB_DATA_5
46 EB_IO_CS0n
47 UARTC1_TX
48 UARTC1_RX
49 EB_IO_WEn
50 EB_IO_OEn
1
2
2
1
1
1
2
2
1
2
2
O
O
-
-
-
-
-
-
-
-
-
-
-
External Bus I/O Latch Enable 2 for External Address Bits A[9:2]
External Bus Address Bit 1
External Bus Address Bit 0
External Bus Data Bit 3
O
I/O
I/O
I/O
O
External Bus Data Bit 2
External Bus Data Bit 5
External Bus Chip Select 0
O
CLI UART 1 Transmit
I
CLI UART 1 Receive
O
External Bus Write Enable Strobe
External Bus Output Enable Strobe
O
NO IPCS SPI/FLASH PROGRAMMING (NOTE 14)
33 IPCS_MISO
TYPE
I/O
PULL DESCRIPTION
2
1
1
1
1
O
I
-
-
-
-
SPI Flash Emulation (MISO) Master in Slave Out Port
35 IPCS_MOSI
SPI Flash Emulation (MOSI) Master Out Slave in Port
SPI Flash Emulation (SCK) Serial Clock Port
SPI Flash Emulation Slave Select, Active Low
36 IPCS_SCK
I
39 IPCS_SSn
I
51 FLASH_P_ENn
EB_IO_LE1
I
O
UP Flash Program Enable, Active Low
UP External Bus I/O Latch Enable 1
NO API UART
TYPE
I/O
I
PULL DESCRIPTION
57 UART_RX_RTSn
58 UART_RX_CTSn
59 UART_RX
1 (Note 13)
-
-
-
-
-
-
UART Receive (RTS) Request to Send, Active Low
UART Receive (CTS) Clear to Send, Active Low
UART Receive
1
O
I
1 (Note 13)
60 UART_TX_RTSn
61 UART_TX_CTSn
62 UART_TX
1
O
I
UART Transmit (RTS) Request to Send, Active Low
UART Transmit (CTS) Clear to Send, Active Low
UART Transmit
1 (Note 13)
2
O
Note 13: These inputs are always enabled and must be driven or pulled to
a valid state to avoid leakage.
Note 14: Embedded programming over the IPCS SPI bus is only available
when RESETn is asserted.
59012iprfa
20
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
pin FuncTions
VSUPPLY: System and I/O Power Supply. Provides power
to the module. The digital-interface I/O voltages are also
set by this voltage.
latches the network timestamp with sub-microsecond
resolution on the rising edge of the TIMEn signal and
produces a packet on the API serial port containing the
timing information.
ANTENNA: Multiplexed Receiver Input and Transmitter
Output Pin. The impedance presented to the MMCX con-
nectorshouldbe50Ω,single-endedwithrespecttoground.
UARTC0_RX, UARTC0_TX, UARTC1_RX, UARTC1_TX:
The CLI UART provides a mechanism for monitoring,
configuration and control of Eterna during operation. On
the LTP5901/2-IPR CLI UART 0 is used when Eterna is not
configured to support external RAM and CLI UART 1 is
used when Eterna is configured to support external RAM.
For a complete description of the supported commands
see the SmartMesh IP Manager CLI Guide.
RESETn:Theasynchronousresetsignalisinternallypulled
up. Resetting Eterna will result in the ARM Cortex-M3
rebooting and loss of network connectivity. Use of this
signal for resetting Eterna is not recommended, except
during power-on and in-circuit programming.
RADIO_INHIBIT: The radio inhibit function is currently
not supported by software. RADIO_INHIBIT provides a
mechanism for an external device to temporarily disable
radiooperation.Failuretoobservethetimingrequirements
defined in the RADIO_INHIBIT AC Characteristics section,
may result in unreliable netowrk operation. In designs
where the RADIO_INHIBIT function is not needed the
input must either be tied, pulled or actively driven low to
avoid excess leakage.
EB_DATA_0 through EB_DATA_7, EB_ADDR_0, EB_
ADDR_1, EB_IO_LE1 through EB_IO_LE2, EB_IO_CS0n,
EB_IO_WEn, EB_IO_ENn: The external bus provides a
multiplexed address data bus enabling the Cortex-M3
direct access of external byte wide RAM. The additional
RAM is used by network management software enabling
thesupportofalargernetworkofmoteswithhigherpacket
throughput. To support the addressing needed, each
latch signal, EB_IO_LE0, EB_IO_LE1, and EB_IO_LE2 will
strobe to latch 8-bits of address from the EB_DATA[7:0]
bus.EB_IO_LE0,EB_IO_LE1,andEB_IO_LE2correspond
to addres bits [25:18], [17:10] and [9:2] respectively.
EB_ADDR_0 and EB_ADDR_1 correspond to the lower
two bits of address. For systems with 256k bytes or less
EB_IO_LE2canbeignored.EB_IO_CS0n,EB_IO_WEnand
EB_IO_OEn provide chip select, write enable and output
enable control of the external RAM.
TMS, TCK, TDI, TDO: JTAG port supporting software
debug and boundary scan.
SLEEPn: The SLEEPn function is not currently supported
in software. The SLEEPn input must either be tied, pulled
or actively driven high to avoid excess leakage.
UART_RX,UART_RX_RTSn,UART_RX_CTSn,UART_TX,
UART_TX_RTSn,UART_TX_CTSn:TheAPIUARTinterface
includes bi-directional wake up and flow control. Unused
inputsignalsmustbedrivenorpulledtotheirinactivestate.
FLASH_P_ENn, IPCS_SSn, IPCS_SCK, IPCS_MISO,
IPCS_SSn: The In-circuit programming control system
(IPCS)busenablesin-circuitprogrammingofEterna’sflash
memory. IPCS_SCK is a clock and should be terminated
appropriately for the driving source to prevent overshoot
and ringing.
TIMEn:StrobingtheTIMEninputisthemostaccuratemeth-
odtoacquirethenetworktimemaintainedbyEterna.Eterna
59012iprfa
21
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
TheLTP5901/LTP5902istheworld’smostenergy-efficient
IEEE 802.15.4 compliant platform, enabling battery and
energyharvestedapplications.Withapowerful32-bitARM
Cortex-M3, best-in-class radio, flash, RAM and purpose-
built peripherals, Eterna provides a flexible, scalable and
robust networking solution for applications demanding
minimal energy consumption and data reliability in even
the most challenging RF environments.
Shown in Figure 10, Eterna integrates purpose-built pe-
ripheralsthatexcelinbothlowoperating-energyconsump-
tion and the ability to rapidly and precisely cycle between
operating and low power states. Items in the gray shaded
region labeled analog core correspond to the analog/RF
components.
32kHz
DIGITAL CORE
ANALOG CORE
32kHz, 20MHz
TIMERS
SCHED
VOLTAGE REFERENCE
PRIMARY
CORE REGULATOR
CLOCK REGULATOR
ANALOG REGULATOR
DC/DC
SRAM
72kB
CONVERTER
PMU/
RELAXATION
OSCILLATOR
FLASH
512kB
CLOCK
CONTROL
PA
DC/DC
CONVERTER
PoR
20MHz
FLASH
CONTROLLER
802.15.4
MOD
LPF
DAC
AES
PA
CODE
802.15.4
FRAMING
DMA
PLL
AUTO
MAC
SYSTEM
802.15.4
DEMOD
BPF
PPF
LNA
ADC
LIMITER
AGC
RSSI
BAT
LOAD
IPCS
SPI
SLAVE
CLI
UART
(2 PIN)
API
ADC
CTRL
10-BIT
ADC
UART
(6 PIN)
VGA
PTAT
4-BIT
DAC
59012IPR F10
Figure 10. Eterna Block Diagram
59012iprfa
22
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
POWER SUPPLY
with other wireless products. In addition, precise timing
enablesnetworkstoreducespectraldeadtime, increasing
total network throughput.
Eterna is powered from a single pin, VSUPPLY, which
powers the I/O cells and is also used to generate internal
supplies.Eterna’stwoon-chipDC/DCconvertersminimize
Eterna’senergyconsumptionwhilethedeviceisawake.To
conserve power the DC/DC converters are disabled when
the device is in low power state. Eterna’s integrated power
supply conditioning architecture, including the two inte-
gratedDC/DCconvertersandthreeintegratedlowdropout
regulators, provides excellent rejection of supply noise.
Eterna’s operating supply voltage range is high enough
to support direct connection to lithium-thionyl chloride,
Li-SOCl2, sources and wide enough to support battery
operation over a broad temperature range.
APPLICATION TIME SYNCHRONIꢀATION
In addition to coordinating time slots across the network,
which is transparent to the user, Eterna’s timing manage-
mentisusedtosupporttwomechanismstosharenetwork
time. Having an accurate, shared, network-wide time base
enables events to be accurately time stamped or tasks to
be performed in a synchronized fashion across a network.
Eterna will send a time packet through its serial interface
when one of the following occurs:
• Eterna receives an API request to read time
• The TIMEn signal is asserted
SUPPLY MONITORING AND RESET
TheuseofTIMEnhastheadvantageofbeingmoreaccurate.
The value of the timestamp is captured in hardware relative
to the rising edge of TIMEn. If an API request is used, due
to packet processing, the value of the timestamp may be
capturedseveralmillisecondsafterreceiptofthepacketdue
topacketprocessing.SeesectionTIMEnACCharacteristics,
for the time function’s definition and specifications.
Eterna integrates a power-on reset (PoR) circuit. As the
RESETn input pin is nominally configured with an internal
pull-up resistor, no connection is required. For a graceful
shutdown, the software and the networking layers should
be cleanly halted via API commands prior to assertion of
theRESETnpin.SeetheSmartMeshIPManagerAPIGuide
for details on the disconnect and reset commands. Eterna
includes a soft brown-out monitor that fully protects the
flash from corruption in the event that power is removed
while writing to flash. Integrated flash supervisory func-
tionality, in conjunction with a fault tolerant file system,
yields a robust non-volatile storage solution.
TIME REFERENCES
Eterna includes three clock sources: an internal relaxation
oscillator, a low power oscillator designed for a 32.768kHz
crystal, and the radio reference oscillator designed for a
20MHz crystal.
PRECISION TIMING
Relaxation Oscillator
A major feature of Eterna over competing 802.15.4 prod-
uct offerings is its low power dedicated timing hardware
and timing algorithms. This functionality provides timing
precision two to three orders of magnitude better than
any other low power solution available at the time of
publication. Improved timing accuracy allows motes to
minimize the amount of radio listening time required to
ensure packet reception thereby lowering even further
the power consumed by SmartMesh networks. Eterna’s
patented timing hardware and timing algorithms provide
superior performance over rapid temperature changes,
further differentiating Eterna’s reliability when compared
The relaxation oscillator is the primary clock source for
Eterna, providing the clock for the CPU, memory subsys-
tems, and all peripherals. The internal relaxation oscillator
is dynamically calibrated to 7.3728MHz. The internal re-
laxation oscillator typically starts up in a few μs, providing
anexpedient, lowenergymethodfordutycyclingbetween
active and low power states. Quick start-up from the doze
state,definedintheStateDiagramsection,allowsEternato
wakeupandreceivedataovertheUARTandSPIinterfaces
by simply detecting activity on the appropriate signals.
59012iprfa
23
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
32.768kHz Crystal
API UART PROTOCOL
Once Eterna is powered up and the 32.768kHz crystal
source has begun oscillating, the 32.768kHz crystal re-
mains operational while in the active state, and is used as
the timing basis when in doze state. See the State Diagram
section, for a description of Eterna’s operational states.
The API UART protocol was created with the goal of sup-
portingawiderangeofcompanionmultipointcontrolunits
(MCUs)whilereducingpowerconsumptionofthesystem.
The receive half of the API UART protocol includes two ad-
ditional signals in addition to UART_RX: UART_RX_RTSn
and UART_RX_CTSn. The transmit half of the API UART
protocol includes two additional signals in addition to
UART_TX: UART_TX_RTSn and UART_TX_CTSn. The
API UART protocol is referred to as Mode 4.
20MHz Crystal
The 20MHz crystal source provides a frequency reference
for the radio, and is automatically enabled and disabled
by Eterna as needed.
In the figures accompanying the protocol descriptions,
signals driven by the companion processor are drawn
in black and signals driven by Eterna are drawn in blue.
RADIO
Eterna includes the lowest power commercially available
2.4GHz IEEE 802.15.4e radio by a substantial margin.
(Please refer to section Radio Specifications, for power
consumption numbers). Eterna’s integrated power ampli-
fier is calibrated and temperature-compensated to con-
sistently provide power at a limit suitable for worldwide
radio certifications. Additionally, Eterna uniquely includes
a hardware-based autonomous MAC that handles precise
sequencing of peripherals, including the transmitter, the
receiver, and advanced encryption standard (AES) periph-
erals. The hardware-based autonomous media access
controller (MAC) minimizes CPU activity, thereby further
decreasing power consumption.
UART Mode 4
UART Mode 4 incorporates level-sensitive flow control
on the TX channel and requires no flow control on the
RX channel, supporting 115200 baud. The use of level-
sensitive flow control signals enables higher data rates
with the option of using a reduced set of the flow control
signals; however, Mode 4 has specific limitations. First,
the use of the RX flow control signals (UART_RX_RTSn
and UART_RX_CTSn) for Mode 4 are optional provided
the use is limited to the industrial temperature range
(–40°Cto85°C);otherwise, theflowcontrolismandatory.
If RX flow control signals are not used, UART_RX_RTSn
shouldbetiedtoVSUPPLY(inactive)andUART_RX_CTSn
should be left unconnected. Second, unless the com-
panion processor is always ready to receive a packet,
the companion processor must negate UART_TX_CTSn
prior to the end of the current packet. Failure to negate
UART_TX_CTSn prior to the end of a packet may result
in back to back packets. Third, the companion processor
UARTS
The principal network interface is through the applica-
tion programming interface (API) UART. A command-line
interface (CLI) is also provided for support of test and
debug functions. Both UARTs sense activity continuously,
consumingvirtuallynopoweruntildataistransferredover
the port and then automatically returning to their lowest
power state after the conclusion of a transfer. The defini-
tion for packet encoding on the API UART interface can
be found in the SmartMesh IP Manager API Guide and the
CLI command definitions can be found in the SmartMesh
IP Manager CLI Guide.
must wait at least t
between transmitting
RX_INTERPACKET
packets on UART_RX. See the UART AC Characteristics
section for complete timing specifications. Packets are
HDLCencodedwithonestopbitandnoparitybit. Theflow
control signals for the TX channel are shown in Figure 11.
TransfersareinitiatedbyEternaassertingUART_TX_RTSn.
59012iprfa
24
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
The UART_TX_CTSn signal may be actively driven by the
companion processor when ready to receive a packet or
UART_TX_CTSn may be tied low if the companion pro-
cessor is always ready to receive a packet. After detecting
a logic ‘0’ on UART_TX_CTSn Eterna sends the entire
packet. Following the transmission of the final byte in
the packet Eterna negates UART_TX_RTSn and waits for
to remain inactive during the majority of the radio activity.
The autonomous MAC, provides software-independent
timing control of the radio and radio-related functions,
resultinginsuperiorreliabilityandexceptionallylowpower.
SECURITY
Network security is an often overlooked component of a
complete network solution. Proper implementation of se-
curity protocols is significant in terms of both engineering
effort and market value in an OEM product. Eterna system
solutionsprovideaFIPS-197validatedencryptionscheme
that includes authentication and encryption at the MAC
and network layers with separate keys for each mote.
This not only yields end-to-end security, but if a mote is
somehowcompromised,communicationfromothermotes
is still secure. A mechanism for secure key exchange al-
lows keys to be kept fresh. To prevent physical attacks,
Eternaincludeshardwaresupportforelectronicallylocking
devices, thereby preventing access to Eterna’s flash and
RAM memory and thus the keys and code stored therein.
t
, defined in the UART AC Characteristics
TX_INTERPACKET
section, before asserting UART_TX_RTSn again.
For details on the timing of the UART protocol, see the
UART AC Characteristics section.
UART_TX_RTSn
UART_TX_CTSn
UART_TX
BYTE 0
BYTE 1
59012IPR F11
Figure 11. UART Mode 4 Transmit Flow Control
CLI UART
The command line interface (CLI) UART port is a two
wire protocol (TX and RX) that operates at a fixed 9600
baud rate with one stop bit and no parity. The CLI UART
interfaceisintendedtosupportcommandlineinstructions
and response activity.
TEMPERATURE SENSOR
Eterna includes a calibrated temperature sensor on chip.
The temperature readings are available locally through
Eterna’s serial API, in addition to being available via the
network manager. The performance characteristics of
the temperature sensor can be found in the Temperature
Sensor Characteristics section.
AUTONOMOUS MAC
Eterna was designed as a system solution to provide a
reliable, ultralow power, and secure network. A reliable
network capable of dynamically optimizing operation
over changing environments requires solutions that are
far too complex to completely support through hardware
acceleration alone. As described in the Precision Timing
section,propertimemanagementisessentialforoptimizing
a solution that is both low power and reliable. To address
theserequirementsEternaincludestheautonomousMAC,
which incorporates a coprocessor for controlling all of
the time-critical radio operations. The autonomous MAC
provides two benefits: first, preventing variable software
latency from affecting network timing and second, greatly
reducing system power consumption by allowing the CPU
RADIO INHIBIT
The RADIO_INHIBIT input enables an external control-
ler to temporarily disable the radio software drivers (for
example, to take a sensor reading that is susceptible to
radio interference). When RADIO_INHIBIT is asserted
the software radio drivers will disallow radio operations
including clear channel assessment, packet transmits, or
packet receipts. If the radio is active in the current time
slot when RADIO_INHIBIT is asserted the radio will be
disabledafterthepresentoperationcompletes. Fordetails
on the timing associated with RADIO_INHIBIT, see the
RADIO_INHIBIT AC Characteristics section.
59012iprfa
25
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
SOFTWARE INSTALLATION
Where:
Devices are supplied with the flash erased, requiring pro-
gramming as part of the OEMs manufacturing procedure.
The US Department of Commerce places restrictions on
export of systems and software supporting encryption.
All of Linear/Dust product software produced to date
contains encryption and is subject to export regulations
and may be provided only via MyLinear, https://www.
linear.com/mylinear. Customers purchasing SmartMesh
products will receive a certificate containing a registration
key and registration instructions with their order. After
registering with the key, customers will be able to
download SmartMesh software images from MyLinear.
Once registered, customers will receive automated e-mail
notifications as software updates are made avaialbe.
AF = acceleration factor
Ea = activation energy = 0.6eV
–5
k = 8.625 • 10 eV/°K
T
T
= is the specified temperature retention in °C
USE
= actual storage temperature in °C
STRESS
Example: Calculate the effect on retention when storing
at a temperature of 105°C.
T
T
= 105°C
STRESS
= 85°C
USE
AF = 2.8
So the overall retention of the flash would be degraded
by a factor of 2.8, reducing data retention from 20 years
at 85°C to 7.1 years at 105°C.
Linear Technology offers the DC9010, in circuit program-
mer for the Eterna based products. While the DC9010, is
provided as a finished product, the design documents are
provided as a reference for customers.
NETWORKING
Oncesoftwarehasbeenloaded,devicescanbeconfigured
via either the CLI or API ports. Configuration commands
and settings are defined in SmartMesh IP Manager API
Guide and SmartMesh IP Manager CLI Guide.
The LTP5901-IPR/LTP5902-IPR network manager pro-
vides the ingress/egress point for at the wired to wireless
mesh network boundary, via the API UART interface. The
complexity of the mesh network management is handled
entirely within the embedded software, which provides
dynamic network optimization, deterministic power man-
agement, intelligent routing, and configurable bandwidth
allocation while achieving carrier class data reliability and
low power operation.
FLASH DATA RETENTION
Eterna contains internal flash (non-volatile memory) to
store calibration results, unique ID, configuration settings
and software images. Flash retention is specified over the
operatingtemperaturerange.SeeElectricalCharacteristics
and Absolute Maximum Ratings sections.
Dynamic Network Optimization
Non destructive storage above the operating temperature
range of –40°C to 85°C is possible; although, this may
result in a degradation of retention characteristics.
Dynamic network optimization allows Eterna to address
the changing RF requirements in harsh industrial en-
vironments resulting in a network that is continuously
self-monitoringandself-adjusting.Themanagerperforms
dynamicnetworkoptimizationbaseduponperiodicreports
on network health and link quality that it receives from
the network motes. The manager uses this information
to provide performance statistics to the application layer
and proactively solve problems in the network. Dynamic
The degradation in flash retention for temperatures >85°C
can be approximated by calculating the dimensionless
acceleration factor using the following equation.
Ea
k
1
1
•
−
AF = e
T
+273
T
+273
USE
STRESS
59012iprfa
26
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
requirements, such as request/response, fast file trans-
fer, and alerting. Relevant configuration parameters are
described in the SmartMesh IP Users Guide. The design
trade-offs between network performance and current
consumption are supported via the SmartMesh Power
and Performance Estimator.
network optimization not only maintains network health,
but also allows Eterna to deliver deterministic power
management. One of the key advantages of SmartMesh
networking solutions is the network manager is aware of
and tracking the success or failure of every packet trans-
action, so not only can the network be optimized, but the
solution can be rigorously tested to produce a system
solution with better than 99.999% reliability.
IP Manager Options
The IP Manager can operate with or without external
SRAM, as described in the LTP5901 and LTP5902 Inte-
gration Guide. When used without external SRAM, the IP
manager is limited to managing networks of 32 motes
or fewer and is limited to a maximum packet throughput
of 24 packets per second. With external SRAM, the IP
Managersupportsmanagingnetworksofupto100motes
and the packet throughput of the IP Manager increases
from 24 packets per second to 36 packets per second.
Deterministic Power Management
Deterministic power management balances traffic in the
network by diverting traffic around heavily loaded motes
(for example, motes with high reporting rates). In do-
ing so, it reduces power consumption for these motes
and balances power consumption across the network.
Deterministic power management provides predictable
maintenance schedules to prevent down time and lower
the cost of network ownership. When combined with field
devices using Eterna’s industry-leading low power radio
technology,deterministicpowermanagementenablesover
a decade of battery life for network motes.
State Diagram
In order to provide capabilities and flexibility in addition
to ultra low power, Eterna operates in various states, as
shown in Figure 12 Eterna State Diagram and described
in this section. State transitions shown in red are not
recommended.
Intelligent Routing
Intelligent routing provides each packet with an optimal
path through the network. The shortest distance between
two points is a straight line, but in RF the quickest path is
notalwaystheonewiththefewesthops.Intelligentrouting
finds optimal paths by considering the link quality (one
path may lose more packets than another) and the retry
schedule, in addition to the number of hops. The result
is reduced network power consumption, elimination of
in-network collisions, and unmatched network scalability
and reliability.
Start-Up
Start-up occurs asa resultofeithercrossing the power-on
reset threshold or asserting RESETn. After the comple-
tion of power-on reset or the falling edge of an internally
synchronized RESETn, Eterna loads its fuse table which,
as described in the previous section, includes setting
I/O direction. In this state, Eterna checks the state of
the FLASH_P_ENn and RESETn and enters the serial
flash emulation mode if both signals are asserted. If the
FLASH_P_ENnpinisnotassertedbutRESETnisasserted,
Eterna automatically reduces its energy consumption to
a minimum until RESETn is released. Once RESETn is
de-asserted, Eterna goes through a boot sequence, and
then enters the active state.
Configurable Bandwidth Allocation
SmartMesh networks provide configurations that enable
users to make bandwidth and latency versus power trade-
offs both network-wide and on a per device basis. This
flexibly enables solutions that tailored to the application
59012iprfa
27
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
Serial Flash Emulation
Operation
When both RESETn and FLASH_P_ENn are asserted,
Eterna disables normal operation and enters a mode to
emulate the operation of a serial flash. In this mode, its
flash can be programmed.
Once Eterna has completed start-up, Eterna transitions to
the operational group of states (active/CPU active, active/
CPU inactive, and Doze). There, Eterna cycles between the
various states, automatically selecting the lowest pos-
sible power state while fulfilling the demands of network
operation.
POWER-ON
RESET
VSUPPLY > PoR
RESETn LOW AND
FLASH_P_ENn LOW
LOAD FUSE
SETTINGS
SET RESETn HIGH AND
FLASH_P_ENn HIGH
FOR 125µs, THEN
SERIAL FLASH
EMULATION
SET RESETn LOW
RESETn LOW AND
FLASH_P_ENn HIGH
RESETn HIGH
AND
FLASH_P_ENn
HIGH
RESET
DEASSERT
RESETn
BOOT
START-UP
ASSERT RESETn ASSERT RESETn
ASSERT RESETn
CPU AND
PERIPHERALS
INACTIVE
CPU
ACTIVE
ACTIVE
DEEP SLEEP
DOZE
CPU
INACTIVE
LOW POWER SLEEP
COMMAND
HW OR PMU EVENT
OPERATION
INACTIVE
59012IPR F12
Figure 12. Eterna State Diagram
59012iprfa
28
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
operaTion
Active State
Doze State
In the active state, Eterna’s relaxation oscillator is running
and peripherals are enabled as needed. The ARM Cortex-
M3cyclesbetweenCPU-activeandCPU-inactive(referred
to in the ARM Cortex-M3 literature as sleep now mode).
Eterna’s extensive use of DMA and intelligent peripherals
that independently move Eterna between active state and
doze state minimizes the time the CPU is active, signifi-
cantly reducing Eterna’s energy consumption.
The doze state consumes orders of magnitude less cur-
rent than the active state and is entered when all of the
peripherals and the CPU are inactive. In the Doze state
Eterna’s full state is retained, timing is maintained, and
Eterna is configured to detect, wake, and rapidly respond
to activity on I/Os (such as UART signals and the TIMEn
pin). In the doze state the 32.768kHz oscillator and as-
sociated timers are active.
applicaTions inFormaTion
REGULATORY AND STANDARDS COMPLIANCE
The RoHS-compliant design features include:
• RoHS-compliant solder for solder joints
• RoHS-compliant base metal alloys
Radio Certification
The LTP5901 and LTP5902 have been certified under a
single modular certification, with the module name of
ETERNA2.Followingtheregulatoryrequirementsprovided
in the ETERNA2 Users Guide can enable customers to
ship products in the supported geographies, by simply
completing an unintentional radiator scan of the finished
product(s). The ETERNA2 Users Guide also provides the
technical information needed to enable customers to fur-
ther certify either the modules or products based upon the
modules in geographies that have not or do not support
modular certification.
• RoHS-compliant precious metal plating
• RoHS-compliant cable assemblies and connector
choices
• Halogen-free mold compound
• RoHS-compliant and 245°C re-flow compatible
Note: Customers may elect to use certain types of lead-
free solder alloys in accordance with the European Com-
munity directive 2011/65/EU. Depending on the type of
solder paste chosen, a corresponding process change to
optimize reflow temperatures may be required.
Compliance to Restriction of Hazardous Substances
(RoHS)
SOLDERING INFORMATION
Restriction of hazardous substances 2(RoHS 2) is a
directive that places maximum concentration limits on
the use of certain hazardous substances in electrical and
electronic equipment. Linear Technology is committed to
meeting the requirements of the European Community
directive 2011/65/EU.
The LTP5901 and LTP5902 are suitable for both eutectic
PbSn and RoHS-6 reflow. The maximum reflow solder-
ing temperature is 260°C. A more detailed description of
layoutrecommendations,assemblyproceduresanddesign
considerations is included in the LTP5901 and LTP5902
Hardware Integration Guide.
This product has been specifically designed to utilize
RoHS-compliant materials and to eliminate or reduce the
use of restricted materials to comply with 2011/65/EU.
59012iprfa
29
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
relaTeD DocumenTaTion
TITLE
LOCATION
DESCRIPTION
SmartMesh IP Users Guide
SmartMesh IP Manager API Guide
http://www.linear.com/docs/41880
http://www.linear.com/docs/41883
Theory of operation for SmartMesh IP networks and motes
Definitions of the applications interface commands available over
the API UART
SmartMesh IP Manager CLI Guide
http://www.linear.com/docs/41882
http://www.linear.com/docs/41877
http://www.linear.com/docs/42916
Definitions of the command line interface commands available
over the CLI UART
LTP5901 and LTP5902 Hardware
Integration Guide
Recommended practices for designing with the LTP5901 and
LTP5902
ETERNA2 Users Guide
The ETERNA2 module user’s guide covering certification
requirements for certified geographies and support
documentation enabling customer certification in additional
geographies for the LTP5901 and LTP5902
SmartMesh IP Tools Guide
http://www.linear.com/docs/42453
The user’s guide for all IP related tools, and specifically the
definition for the on-chip Application Protocol (OAP)
59012iprfa
30
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
package DescripTion
Please refer to http://www.linear.com/product/LTP5901-IPR#packaging for the most recent package drawings.
2.54
.039
1.00
.945
24.00
.039
1.00
1.57
40.00
.039
1.00
1.213
1.122
30.80
28.50
1.102
1.063
1.031
28.00
27.00
26.20
R.010 TYP
0.25
1.654
42.00
.039 TYP
1.00
.079
.039
0
2.00
1.00
0.00
4X
.035
0.90
.039
.08
1.00
2.00
.039 1.00
59012IPR F12
Figure 13. LTP5901 Mechanical Drawing
59012iprfa
31
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
package DescripTion
Please refer to http://www.linear.com/product/LTP5901-IPR#packaging for the most recent package drawings.
.100
2.54
.177
4.50
.039
.945
1.00
24.00
.039
1.00
.029
0.73
1.40 35.50
1.272 32.30
.039
1.00
1.213 30.80
1.122 28.50
1.102 28.00
1.063 27.00
1.031 26.20
R.010 TYP
0.25
1.476
37.50
.039 TYP
1.00
4X
.035
0.90
.079
.039
2.00
1.00
0
0.00
.039
.079
1.00
2.01
.039 1.00
59012IPR F13
Figure 14. LTP5902 Mechanical Drawing
59012iprfa
32
For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
LTP5901-IPR/LTP5902-IPR
revision hisTory
REV
DATE
DESCRIPTION
PAGE NUMBER
A
11/15 Updated ordering part number options.
Added total inductance, capacitance.
5, 27
8
Added Software Installation section.
26
59012iprfa
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representa-
tionth t th in er ne n o its cu tsde ri edhe will ot infr istinat nt ts.
33
ae tconctiofciriasscbreinningeonexgperigh
LTP5901-IPR/LTP5902-IPR
Typical applicaTion
Power over Ethernet Network Manager
SMSC 8710A
(10/100 PHY)
ATMEL SAM4E
LTP5902-IPR
ANTENNA
TXP
TXM
RXP
RXM
PWM
TIMEn
MII
MII
UART
UART
RJ45
1
+
–
14
12
13
1
3
2
TX
TX
2
3
+
10
11
9
5
4
6
RX
RX
–
6
COILCRAFT
ETHI - 230LD
4
5
7
8
LT4265
(PoE PD
INTERFACE
CONTROLLER)
LT8300
(ISOLATED
FLYBACK
0.1µF
100V
SMAJ58A
TVS
CONVERTER)
3.3V
59012IPR TA02
relaTeD parTs
PART NUMBER
LTC5800-IPR
LTP5901-IPM
DESCRIPTION
COMMENTS
QFN Network Manager
IP Wireless Mesh Manager
IP Wireless Mesh Mote PCB Module
with Chip Antenna
Includes Modular Radio Certification in the United States, Canada, Europe, Japan, South
Korea, Taiwan, India, Australia and New Zealand
LTP5902-IPM
LTC2379-18
IP Wireless Mesh Mote PCB Module
with MMCX Antenna Connector
Includes Modular Radio Certification in the United States, Canada, Europe, Japan, South
Korea, Taiwan, India, Australia and New Zealand
18-Bit,1.6Msps/1Msps/500ksps/
250ksps Serial, Low Power ADC
2.5V Supply, Differential Input, 101.2dB SNR, 5V Input Range, DGC
LTC3388-1/
LTC3388-3
20V High Efficiency Nanopower
Step-Down Regulator
860nA I in Sleep, 2.7V to 20V Input, V : 1.2V to 5.0V, Enable and Standby Pins
Q OUT
LTC3588-1
Piezoelectric Energy Generator with
Integrated High Efficiency Buck
Converter
V : 2.7V to 20V; V
: Fixed to 1.8V, 2.5V, 3.3V, 3.6V; I = 0.95μA; 3mm × 3mm
IN
OUT(MIN) Q
DFN-10 and MSOP-10E Packages
Ultralow Voltage Step-Up Converter and V : 0.02V to 1V; V = 2.5V, 3V, 3.7V, 4.5V Fixed; I = 6μA; 3mm × 4mm DFN-12 and
IN OUT
LTC3108-1
LTC3459
LTC4265
LT8300
Q
Power Manager
SSOP-16 Packages
Micropower Synchronous Boost
Converter
V : 1.5V to 5.5V; V
= 10V; I = 10μA; 2mm × 2mm DFN, 2mm × 3mm DFN or
OUT(MAX) Q
IN
SOT-23 Package
IEEE 802.3at High Power PD Interface
Controller with 2-Event Classification
2-Event Classification Recognition, 100mA Inrush Current, Single-Class Programming
Resistor, Full Compliance to 802.3at
100V Micropower Isolated Flyback
Converter with 150V/260mA Switch
6V ≤ V ≤ 100V, No Opto Flyback , 5-Lead TSOT-23 Package
IN
59012iprfa
LT 1115 REV A • PRINTED IN USA
LinearTechnology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417
34
●
●
LINEAR TECHNOLOGY CORPORATION 2014
(408)432-1900 FAX: (408) 434-0507 www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR
相关型号:
LTP5902IPC-IPRB1C1#PBF
LTP5902-IPM - SmartMesh IP Wireless 802.15.4e PCBA Module with Antenna Connector; Pins: 66; Temperature Range: -40°C to 85°C