URF2412LP-20W [MORNSUN]
REGULATED SINGLE OUTPUT DC-DC CONVERTER;型号: | URF2412LP-20W |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | REGULATED SINGLE OUTPUT DC-DC CONVERTER DC-DC转换器 输出元件 |
文件: | 总6页 (文件大小:1369K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FEATURES
● Efficiency up to 89%
● 4:1 wide input voltage range
● Low temperature rise
● Short circuit protection
● 3KVAC isolation
URF_LP-20W SERIES
20W,WIDE INPUT, HIGH ISOLATED & REGULATED
SINGLE OUTPUT DC-DC CONVERTER
● Operating temperature range:
-40°C ~ +85°C
● Industry standard pinout
● Industrial level specifications
● Meet CISPR22/EN55022 CLASS A
Patent Protected RoHS
APPLICATION
PART NUMBER SYSTEM
URF_LP-20W series are applied to wide voltage
range input situation such as power systems, data
transmission device, battery power supply device,
telecommunication device, distributed power supply
system, remote control system, industrial robot system
etc.
URF2405LP-20W
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
SELECTION GUIDE
Input Current
(mA)(typ.)
Reflected
Ripple
Current
③
Input Voltage(VDC)
Output Output Current (mA)
Voltage
Max.
Capacitive
Load (µF)
Efficiency
①
(%, typ.)
@Max. Load
Nominal
(Range)
@Max.
②
Model
(VDC)
Max.
Min.
@No Load
Max
(mA,typ.)
Load
URF2405LP-20W
URF2412LP-20W
URF2415LP-20W
URF2424LP-20W
URF4805LP-20W
URF4812LP-20W
URF4815LP-20W
URF4824LP-20W
5
4000
1667
1334
834
200
84
947
60
15
15
20
35
10
10
10
10000
1600
1000
500
88
88
89
89
88
88
89
89
12
15
24
5
947
937
937
473
473
469
469
24
40
(9-36)
67
42
30
4000
1667
1334
834
200
84
10000
1600
1000
500
12
15
24
48
80
(18-75)
67
42
Note: ①series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting,
for example URF2405LP-20WA2S is chassis mounting ,URF2405LP-20WA4S is DIN-Rail mounting ;
②Absolute maximum rating without damage on the converter;
③The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
INPUT SPECIFICATIONS
Item
Test Conditions
24VDC input
Min.
-0.7
-0.7
--
Typ.
--
Max.
50
100
9
Unit
Input Surge Voltage (1sec.max.)
48VDC input
--
24VDC input
--
VDC
Start-up Voltage
48VDC input
--
--
17.8
--
24VDC input
7.8
16
--
--
Under Voltage Shutdown
Start-up Time
48VDC input
--
Nominal input& constant resistance load
Models ON
--
10
--
ms
Ctrl open or connect TTL high level (2.5-12VDC)
Ctrl connect GND or low level (0-1.2VDC)
Models OFF
Ctrl*
Input current (Models OFF)
--
1
--
mA
Input Filter
Pi Filter
Note: *The Ctrl control pin voltage is refer to GND.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 1of 6
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Unit
%
Output Voltage Accuracy
Line Regulation
±1
±0.2
±0.5
300
±3
±3
±0.5
±1
--
--
--
--
--
Full load, input voltage from low to high
5% to 100% load
Load Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Drift
Ripple & Noise*
500
±5
µs
%
25% load step change
100% load
±0.02
--
%/°C
mVp-p
--
20MHz bandwidth
--
--
--
--
--
--
--
70
100
--
Trim
±10%
5VDC output
12VDC output
15VDC output
24VDC output
6.2
15
--
--
--
--
--
VDC
Output Over Voltage Protection
18
28.8
150
Over Current Protection
Short Circuit Protection
%
Input voltage range
Hiccup, Continuous, automatic recovery
Note:* Ripple and noise tested with “parallel cable” method. See detailed operation instructions at DC-DC application notes.
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
--
Max.
--
Unit
Input-Output, Tested for 1 minute and leakage current less than 5 mA
(Except the pin of Ctrl)
Isolation Voltage
3000
VAC
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
Input-Output, Test at 500VDC
Input-Output,100KHz/0.1V
1000
--
--
1000
300
--
--
--
--
--
MΩ
pF
--
KHz
PWM mode
MIL-HDBK-217F@25℃
1000
K hours
Case Material
Plastic (UL94-V0)
51.50×26.50×12.00
PCB mounting
Size
mm
g
A2S Chassis mounting
A4S DIN-Rail mounting
PCB mounting
76.00×31.50×21.20
76.00×31.50×25.80
--
--
--
25
47
67
--
--
--
Weight
A2S Chassis mounting
A4S DIN-Rail mounting
ENVIRONMENTAL SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
--
Max.
95
Unit
%
Storage Humidity
Operating Temperature
Storage Temperature
The Max. Case Temperature
Lead Temperature
Cooling
Non condensing
5
Power derating (above 65℃, see Figure 3)
-40
-40
--
--
85
--
125
105
°C
Operating Temperature curve range
1.5mm from case for 10 seconds
--
--
--
300
Free air convection
10-55Hz, 10G, 30 Min. along X, Y and Z
Shake
EMC SPECIFICATIONS
CE
CISPR22/EN55022 CLASS A(Without External Circuit)/ CLASS B(External Circuit Refer to Figure1-②)
CISPR22/EN55022 CLASS A(Without External Circuit)/ CLASS B(External Circuit Refer to Figure1-②)
EMI
RE
ESD
RS
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
IEC/EN61000-4-5
IEC/EN61000-4-6
Contact ±4KV
10V/m
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria A
EFT
±2KV
(External Circuit Refer to Figure1-①)
(External Circuit Refer to Figure1-①)
EMS
Surge
±2KV
CS
3 Vr.m.s
Voltage dips, short and
interruptions immunity
IEC/EN61000-4-29 0%-70%
perf. Criteria B
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 2of 6
EMC RECOMMENDED CIRCUIT
Recommended external circuit parameters:
Model
FUSE
MOV
LDM1
TVS
C0
Vin:24V
Vin:48V
FUSE
MOV
CY2
LDM2
V in
Vin
+Vo
Choose according to actual input current
LDM1
+
S14K35
S14K60
LOAD
EUT
C1
TVS
C0
56μH
-Vo
(0V)
GND
GND
SMCJ48A
330μF/50V
1μF /50V
SMCJ90A
330μF/100V
1μF /100V
CY1
①
②
C1
(Figure1)
Note: In Figure 1,part①is EMS recommended external circuit, part② is EMI
LDM2
4.7μH
recommended external circuit. Choose according to requirements.
CY1,CY2
1nF/5KV
EMC RECOMMENDED CIRCUIT PCB LAYOUT
(Figure 2)
Note: The pad space between input and output (CY1/CY2) must≥2mm.
EMI TEST WAVEFORM(RECOMMENDED CIRCUIT 1-②)
URF2405LP-20W CE (Class B, Positive line)
URF4815LP-20W CE (Class B, Positive line)
URF2405LP-20W RE(Class B, Horizontal)
URF2405LP-20W CE (Class B, Negative line)
URF4815LP-20W CE (Class B, Negative line)
URF2405LP-20W RE(Class B, Vertical)
URF4815LP-20W RE(Class B, Horizontal)
URF4815LP-20W RE(Class B, Vertical)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 3of 6
PRODUCT TYPICAL PERFORMANCE CURVE
Temperature Derating Graph
120
100
80
60
40
20
0
Safe Operating Area
-40
0
40 65 8085
120
Operating Temp(°C)
(Figure 3)
Efficiency VS Input Voltage curve
(Full Load)
Efficiency VS Output Load curve
(Vin=Vin-nominal)
URF2405LP-20W
URF2405LP-20W
100
95
90
85
80
75
70
65
60
55
50
100
90
80
70
60
50
40
30
20
10
0
9
12 15 18 21 24 27 30 33 36
Input Voltage(V)
5
10 20 30 40 50 60 70 80 90 100
Total Output Current (%)
Efficiency VS Input Voltage curve
Efficiency VS Output Load curve
(Vin=Vin-nominal)
URF4815LP-20W
(Full Load)
URF4815LP-20W
100
95
90
85
80
75
70
65
60
55
50
100
90
80
70
60
50
40
30
20
10
0
18 24 30 36 42 48 54 60 66 72 75
5
10 20 30 40 50 60 70 80 90 100
Input Voltage(V)
Total Output Current (%)
URF-LP-20W OUTLINE DIMENSIONS, RECOMMENDED FOOTPRINT
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 4of 6
URF_LP-20WA2S SCHASSIS MOUNTING OUTLINE DIMENSIONS
Footprint Details:
Pin
1
2
3
4
5
6
Function
Ctrl
GND
Vin
0V
Trim
+Vo
URF_LP-20WA4S DIN-RAIL MOUNTING OUTLINE DIMENSIONS
DIN-rail modules are fitting to TS35 rails
Footprint Details:
Pin
1
2
3
4
5
6
Function
Ctrl
GND
Vin
0V
Trim
+Vo
PACKAGE DIAGRAM
PCB mounting Series(Without heat sink)
Special Package Series(A2S/A4S)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 5of 6
TEST CONFIGURATIONS
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
Oscilloscope
Lin
Current
Probe
Load
Cin
DC
DC
Lin(4.7µH)
Cin(220µF, ESR < 1.0Ω at 100 KHz)
TRIM APPLICATION & TRIM RESISTANCE
Application circuit for TRIM (Part in broken line is the interior of models) Formula for resistance of TRIM
+Vo
+Vo
aR
-a
aR
-a
2
Vref
Vo’-Vref
Vo’-Vref
Vref
-R
3
up:
R
T
=
a=
a=
R
1
2
R
2
1
R1
down:
-R3
R
T
=
R
RT
R
1
R1
R3
Vref
R2
Trim
R3
Vref
R2
Trim
RT
0V
Trim down
0V
Trim up
Note: Leave open if not used. Value for R1, R2, R3, and V refer to the above table 1. RT: Resistance of Trim. a: User-defined parameter, no actual
ref
meanings. Vo’: The trim up/down voltage.
(Table 1)
Vo
5(VDC)
12(VDC)
15(VDC)
24 (VDC)
Parameter
R1(KΩ)
2.883
2.864
12.1
2.5
10.971
2.864
17.8
14.497
2.864
17.8
24.872
2.863
20
R2(KΩ)
R3(KΩ)
Vref(V)
2.5
2.5
2.5
DESIGN CONSIDERATIONS
1) Recommended circuit
All the URF_LP-20W Series have been tested according to the following recommended test circuit before leaving the factory (see Figure 4).
If you want to further decrease the input/output ripple, you can increase a capacitance-values properly or choose capacitors with low ESR, but
the total capacitance of the filter capacitor must not exceed the Max Capacitive Load. The recommended capacitance of its filter capacitor sees
Table 2.
Output voltage
(VDC)
Single Output
Vin
Cout(μF) Cin(μF)
+Vo
0V
5
470
Cin
Cout
DC DC
100
12/15
24
220
100
GND
(Figure 4)
(Table 2)
2) It is not recommended to increase the output power capability by connecting two or more converters in parallel.The product is not
hot-swappable
Note:
1. Min. load shouldn't be less than 5%, otherwise ripple maybe increased dramatically, If the product operates under min. load, it may not be
guaranteed to meet all specifications listed. Operation under minimum load will not damage the converter.
2. Max. Capacitive Load is tested at input voltage range and full load.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all test methods are based on our corporate standards.
5. All characteristics are for listed models, and non-standard models may perform differently. Please contact our technical support for more details.
6. Please contact our technical support for any specific requirement.
7. Specifications of this product are subject to changes without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: info@mornsun.cn
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URF_LP-20W
2013.05.24-A/1
Page 6of 6
相关型号: