AC/DC Power Supplies  
Electrical Specifications  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
20W Output Power  
Universal 85-264 VAC Input  
EN 60950 Approved  
Adjustable Output  
Input  
Parameter  
Conditions  
Min.  
85  
120  
47  
Typ.  
Max.  
264  
370  
63  
Units  
VAC  
VDC  
Hz  
Input Voltage Range  
Input Frequency  
Input Current  
See Model Selection Guide  
115 VAC  
230 VAC  
16.0  
30.0  
Meets EN55022 B  
>200 kHour MTBF  
Compact PC Mount Case  
Inrush Current  
A Pk  
EMI  
Meets CISPR Pub. 22/FCC Class B  
115 VAC  
230 VAC  
0.1  
0.3  
Safety Ground Leakage Current  
mA  
Output  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
Output Voltage  
Output Current  
Output Voltage Accuracy  
Line Regulation  
Load Regulation  
Ripple & Noise (20 MHz)  
See Model Selection Guide  
See Model Selection Guide  
2.0  
0.5  
See Model Selection Guide  
%
50  
20  
80  
mV Pk - Pk  
mSec  
115 VAC  
230 VAC  
Hold-Up Time  
Temperature Coefficient  
Short Circuit Protection  
Overload Protection  
General  
0.02  
%/°C  
Continuous (Autorecovery)  
Typ. 110% of Output Power  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
Input to Output 3,000  
Input to Ground 1,500  
Isolation Voltage  
EMI/RFI  
VAC  
Output to Ground  
Conducted  
Electrostatic Discharge (ESD)  
RF Field Susceptibility  
500  
EN 55022 Level B  
IEC/EN 61000-4-2 Level 3  
IEC/EN61000-4-3  
EMC Compliance  
Electrical Fast Transients/Bursts On Mains  
IEC/EN 61000-4-4 Level 3 2 kV  
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV  
Switching Frequency  
Environmental  
Parameter  
150  
kHz  
Conditions  
Min.  
-25  
Typ.  
+25  
Max.  
+70  
+90  
Units  
°C  
°C  
Ambient  
Case  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
-25  
+105  
°C  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 85  
%
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
2.75 x 1.88 x 0.92 Inches (70.0 x 48.0 x 23.5 mm)  
Non-Conductive Black Plastic (UL94-V0)  
5.65 Oz (160g)  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
200  
kHours  
Safety Standards  
Safety Approvals  
IEN 60950, IEC 60950  
IEN 60950, IEC 60950  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output 1 (Vout 1)  
Current (A)  
Model  
Number  
Efficiency  
(%, Typ)  
Current (A)  
Over Volt.  
Protection  
Voltage  
(VDC)  
Load  
115 VAC  
230 VAC  
Typ.  
(VDC)  
Reg.  
MPM-20S-03  
MPM-20S-05  
MPM-20S-12  
MPM-20S-15  
MPM-20S-24  
0.33  
0.33  
0.33  
0.33  
0.33  
0.18  
0.18  
0.18  
0.18  
0.18  
3.3  
5.0  
12.0  
15.0  
24.0  
4.10  
3.50  
1.60  
1.30  
0.85  
1.0%  
1.0%  
1.0%  
1.0%  
1.0%  
6.5  
6.5  
20.0  
20.0  
30.0  
82  
82  
82  
82  
82  
Derating Curve  
Dual & Triple Output Models Are Available.  
For more information, contact the factory:  
sales@micropowerdirect.com  
Notes:  
1. Load regulation is measured for an output change of 10% to 90% at nominal input  
line. For multiple output models, the loads are balanced.  
2. As shown in the connection diagram at right, a simple external circuit may be used to  
adjust the power supply output 10%.To adjust the output DOWN, connect a 5%, 3W resistor  
between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W  
resistor between the minus output pin and the Vout trim. Contact the factory for resistor values  
needed to achieve a specific output.  
3. It is recommended that a fuse be used on the input of a power supply for protection.  
For the MPM-20S series, a 3.15A/250 VAC slow blow should be used.  
Mechanical Dimensions  
Typical Connection  
Typical Component Values  
Vout  
3.3  
C1  
C2  
Fuse  
TVS  
330 µF/16V  
330 µF/16V  
220 µF/25V  
220 µF/25V  
220 µF/35V  
P6KE6.8A  
P6KE6.8A  
P6KE16A  
P6KE20A  
P6KE33A  
5.0  
3.15A/  
250 VAC  
12.0  
15.0  
24.0  
0.01 µF/25V  
Notes:  
Pin  
All dimensions are typical in inches (mm)  
Notes:  
Tolerance x.xx = 0.01 ( 0.25)  
1. C1 is a high frequency, low resistance electrolytic capacitor. Refer to the suppliers specifications  
for capacitance/current ratings.  
2. Voltage derating on all capacitors should be 80% or higher.  
3. C2 eliminates high frequency noise.  
4. The power supply includes an internalTVS.If the user requires a tighter OVP threshold,an external  
TVS may be connected as shown.  
Connections  
Pin  
Function  
1
2
3
AC-Ground  
AC-Neutral  
AC-Line  
-Vout  
4
8
+Vout  
Trim  
Trim  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM-20S-15

Universal Input, 20W Miniature, PC Mount AC/DC Power Supplies
MPD

MPM-20S-24

Universal Input, 20W Miniature, PC Mount AC/DC Power Supplies
MPD

MPM-20SV

20W Output Power
MPD

MPM-20SV-03

20W Output Power
MPD

MPM-20SV-05

20W Output Power
MPD

MPM-20SV-09

20W Output Power
MPD

MPM-20SV-12

20W Output Power
MPD

MPM-20SV-15

20W Output Power
MPD

MPM-20SV-24

20W Output Power
MPD

MPM-24M

24W Output Power
MPD

MPM-24MD-12xx

24W Output Power
MPD

MPM-24MD-15xx

24W Output Power
MPD