MPM30T3512CM [MPD]
MPM-30CM Series;型号: | MPM30T3512CM |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MPM-30CM Series |
文件: | 总2页 (文件大小:263K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPM-30CM
Chassis Mount, 30W
Single, Dual & Triple Out
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 30W Output Power
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Conditions
Min.
85
47
Typ.
Max.
265
440
Units
VAC
Hz
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• Single, Dual & Triple Outputs
• Meets EN 55022 B
See Model Selection Guide
115 VAC
230 VAC
20.0
40.0
Inrush Current
A Pk
EMI
Output
Parameter
Meets CISPR Pub. 22/FCC Class B
• Meets IEC Safety Class II
• Chassis Mount Case
Conditions Min. Typ.
Max.
Units
Output Voltage
Output Current
See Model Selection Guide
See Model Selection Guide
PCB Mount Models
& DIN Rail Mount
Option Available!
Output Voltage Accuracy, Note 1
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
1.0
2.0
1.0
1.0
5.0
5.0
%
%
%
%
%
%
VIN = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
0.2
0.5
2.5
2.5
4.0
1.5
1.0
20
3.3 & 5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
1.8
1.3
Ripple & Noise (20 MHz)
%VP-P of VO
Hold-Up Time
mSec
%/°C
% of VO
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 4
Overload Protection, Note 5
General
0.02
120
Zener Diode Clamp
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Parameter
Conditions
Input to Output 3,000
Input to Output, Flash Tested For 60S 4,700
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
Typ.
Max.
Units
VAC
VAC
M
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
100
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EMC Compliance
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
100
kHz
Conditions
Min.
-25
-40
Typ.
+25
Max.
+71
+85
Units
°C
°C
Ambient
MicroPower Direct
292 Page Street
Suite D
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
%
Stoughton, MA 02072
USA
Physical
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
6.72 Oz (191g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
250
kHours
Safety Standards
Safety Approvals
Safety Class
UL 60950, EN 60950
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output 1 (Vout 1)
Current (A)
Output 2 (Vout 2)
Output 3 (Vout 3)
Current (A)
Capacitive
Load
Effi-
ciency
(%, Typ)
Model
Number
Current (A)
Current (A)
Voltage
Voltage
(VDC)
Voltage
(VDC)
(µF, Max)
(VDC)
115 VAC 230 VAC
Max.
Min.
Max. Min.
Max.
Min.
MPM-30S-05CM
MPM-30S-12CM
MPM-30S-15CM
MPM-30S-24CM
MPM-30S-48CM
MPM-30D-12CM
MPM-30D-15CM
MPM-30T-0512CM 0.572
MPM-30T-0512CMA 0.572
MPM-30T-0515CM 0.572
MPM-30T-5312CM 0.588
MPM-30T-3512CM 0.483
0.557
0.543
0.543
0.543
0.543
0.565
0.543
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
6.000
2.500
2.000
1.250
0.625
0.600
0.250
0.200
0.125
0.063
8,000
3,900
3,900
1,500
1,000
1,500
1,500
See Note 6 76
See Note 6 76
See Note 6 76
78
12.0
15.0
24.0
48.0
+12.0
+15.0
5.0
5.0
5.0
5.0
3.3
80
80
80
80
80
80
+1.300 +0.130 -12.0
+1.000 +0.100 -15.0
-1.300 -0.130
-1.000 -0.100
3.000
3.000
3.000
4.500
4.000
+0.600 +12.0
+0.600 +12.0
+0.300 +15.0
+0.900 +3.3
+0.800 +5.0
+0.600 +0.120 -12.0
+1.000 +0.200 -12.0
+0.500 +0.050 -15.0
+1.000 +0.220 +12.0
+1.500 +0.300 +12.0
-0.600 -0.120
-0.250 -0.050
-0.500 -0.050
+0.250 +0.050 See Note 6 71
+0.250 +0.050 See Note 6 71
Derating Curve
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±±4.
2. Load regulation is measured for an output change of 04 to 1004 at nominal input line.For multiple
output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not meet all specifications.
±. Output short circuit protection is provided by a“hiccup mode”circuit.The unit recovers automati-
cally when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit.
6. For triple output models, the maximum capacitive load for 5VDC and 3.3VDC outputs is 2,200 µF.
For all other outputs it is ±1,500 ꢀF.
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an
external 1.5A slow blow fuse also be used on the input for protection.
Pin Connections
Mechanical Dimensions, Chassis Mount
Pin
Single
Dual
Triple
1
2
3
4
5
6
7
AC-Neutral
AC-Line
+Vo
NC
Common
NC
+Vo
NC
-Vo
NC
NC
+Vo 2
+Vo 1
Common 2/3
-Vo 1
-Vo
+Vo 3
NC = No Connection
Model Number
A DIN Rail mounting kit is available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
• All dimensions are typical in inches (mm)
MicroPower Direct
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
MPM3515
36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS
MPM3515GQV
36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS
MPM3515GQV-AEC1
36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS
MPM3515GQVE-AEC1
36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS
©2020 ICPDF网 联系我们和版权申明