MPM30T3512CM [MPD]

MPM-30CM Series;
MPM30T3512CM
型号: MPM30T3512CM
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MPM-30CM Series

文件: 总2页 (文件大小:263K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MPM-30CM  
Chassis Mount, 30W  
Single, Dual & Triple Out  
AC/DC Power Supplies  
Electrical Specifications  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
30W Output Power  
Input  
Parameter  
Input Voltage Range  
Input Frequency  
Input Current  
Conditions  
Min.  
85  
47  
Typ.  
Max.  
265  
440  
Units  
VAC  
Hz  
Universal 85-265 VAC Input  
EN 60950 Approved (UL)  
Single, Dual & Triple Outputs  
Meets EN 55022 B  
See Model Selection Guide  
115 VAC  
230 VAC  
20.0  
40.0  
Inrush Current  
A Pk  
EMI  
Output  
Parameter  
Meets CISPR Pub. 22/FCC Class B  
Meets IEC Safety Class II  
Chassis Mount Case  
Conditions Min. Typ.  
Max.  
Units  
Output Voltage  
Output Current  
See Model Selection Guide  
See Model Selection Guide  
PCB Mount Models  
& DIN Rail Mount  
Option Available!  
Output Voltage Accuracy, Note 1  
Line Regulation  
Load Regulation, Single Output  
Load Regulation, Dual Output  
Load Regulation, Triple Output - Primary  
Load Regulation, Triple Output - Aux.  
1.0  
2.0  
1.0  
1.0  
5.0  
5.0  
%
%
%
%
%
%
VIN = Min to Max  
IO = Min to Max  
IO = Min to Max  
IO = Min to Max  
IO = Min to Max  
0.2  
0.5  
2.5  
2.5  
4.0  
1.5  
1.0  
20  
3.3 & 5.0 VDC Output  
All Other Outputs  
115 VAC, 60 Hz  
1.8  
1.3  
Ripple & Noise (20 MHz)  
%VP-P of VO  
Hold-Up Time  
mSec  
%/°C  
% of VO  
Temperature Coefficient  
Over Voltage Protection  
Short Circuit Protection, Note 4  
Overload Protection, Note 5  
General  
0.02  
120  
Zener Diode Clamp  
Continuous (Autorecovery)  
Typ. 120% to 180% of Output Power  
Parameter  
Conditions  
Input to Output 3,000  
Input to Output, Flash Tested For 60S 4,700  
500 VDC  
Conducted  
Electrostatic Discharge (ESD)  
RF Field Susceptibility  
Electrical Fast Transients/Bursts On Mains  
Surge  
Min.  
Typ.  
Max.  
Units  
VAC  
VAC  
M  
Isolation Voltage  
Isolation Test Voltage  
Isolation Resistance  
EMI/RFI  
100  
EN 55022 Level B  
EN 61000-4-2 Level B  
EN 61000-4-3  
EMC Compliance  
EN 61000-4-4 Level 3 2 kV  
EN 61000-4-5 Level 3 1kV/2 kV  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
100  
kHz  
Conditions  
Min.  
-25  
-40  
Typ.  
+25  
Max.  
+71  
+85  
Units  
°C  
°C  
Ambient  
MicroPower Direct  
292 Page Street  
Suite D  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 95  
Humidity  
%
Stoughton, MA 02072  
USA  
Physical  
Case Size, Chassis Mount  
Case Size, DIN Rail Option  
Case Material  
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)  
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)  
Non-Conductive Plastic& Fiberglass (UL94-V0)  
6.72 Oz (191g)  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Weight  
Reliability Specifications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
250  
kHours  
Safety Standards  
Safety Approvals  
Safety Class  
UL 60950, EN 60950  
UL, cUL; File No. E245422  
IEC 61140 Class II  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output 1 (Vout 1)  
Current (A)  
Output 2 (Vout 2)  
Output 3 (Vout 3)  
Current (A)  
Capacitive  
Load  
Effi-  
ciency  
(%, Typ)  
Model  
Number  
Current (A)  
Current (A)  
Voltage  
Voltage  
(VDC)  
Voltage  
(VDC)  
F, Max)  
(VDC)  
115 VAC 230 VAC  
Max.  
Min.  
Max. Min.  
Max.  
Min.  
MPM-30S-05CM  
MPM-30S-12CM  
MPM-30S-15CM  
MPM-30S-24CM  
MPM-30S-48CM  
MPM-30D-12CM  
MPM-30D-15CM  
MPM-30T-0512CM 0.572  
MPM-30T-0512CMA 0.572  
MPM-30T-0515CM 0.572  
MPM-30T-5312CM 0.588  
MPM-30T-3512CM 0.483  
0.557  
0.543  
0.543  
0.543  
0.543  
0.565  
0.543  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
0.14  
5.0  
6.000  
2.500  
2.000  
1.250  
0.625  
0.600  
0.250  
0.200  
0.125  
0.063  
8,000  
3,900  
3,900  
1,500  
1,000  
1,500  
1,500  
See Note 6 76  
See Note 6 76  
See Note 6 76  
78  
12.0  
15.0  
24.0  
48.0  
+12.0  
+15.0  
5.0  
5.0  
5.0  
5.0  
3.3  
80  
80  
80  
80  
80  
80  
+1.300 +0.130 -12.0  
+1.000 +0.100 -15.0  
-1.300 -0.130  
-1.000 -0.100  
3.000  
3.000  
3.000  
4.500  
4.000  
+0.600 +12.0  
+0.600 +12.0  
+0.300 +15.0  
+0.900 +3.3  
+0.800 +5.0  
+0.600 +0.120 -12.0  
+1.000 +0.200 -12.0  
+0.500 +0.050 -15.0  
+1.000 +0.220 +12.0  
+1.500 +0.300 +12.0  
-0.600 -0.120  
-0.250 -0.050  
-0.500 -0.050  
+0.250 +0.050 See Note 6 71  
+0.250 +0.050 See Note 6 71  
Derating Curve  
Other output combinations are available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Notes:  
1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±±4.  
2. Load regulation is measured for an output change of 04 to 1004 at nominal input line.For multiple  
output models, the loads are balanced.  
3. Operation at no-load will not damage these units. However, they may not meet all specifications.  
±. Output short circuit protection is provided by ahiccup modecircuit.The unit recovers automati-  
cally when the fault condition is removed.  
5. Output overload protection is provided by a fold back current limiting circuit.  
6. For triple output models, the maximum capacitive load for 5VDC and 3.3VDC outputs is 2,200 µF.  
For all other outputs it is ±1,500 ꢀF.  
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an  
external 1.5A slow blow fuse also be used on the input for protection.  
Pin Connections  
Mechanical Dimensions, Chassis Mount  
Pin  
Single  
Dual  
Triple  
1
2
3
4
5
6
7
AC-Neutral  
AC-Line  
+Vo  
NC  
Common  
NC  
+Vo  
NC  
-Vo  
NC  
NC  
+Vo 2  
+Vo 1  
Common 2/3  
-Vo 1  
-Vo  
+Vo 3  
NC = No Connection  
Model Number  
A DIN Rail mounting kit is available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Notes:  
All dimensions are typical in inches (mm)  
MicroPower Direct  
Tolerance x.xx = ±0.01 (±0.25)  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM30T3512IS

MPM-30IS Series
MPD

MPM30T5312CM

MPM-30CM Series
MPD

MPM30T5312IS

MPM-30IS Series
MPD

MPM3506AGQV

Switching Regulator, Current-mode, 2000kHz Switching Freq-Max, QFN-19
MPS

MPM3510A

36V/1.2A Module Synchronous Step-Down Converter with Integrated Inductor
MPS

MPM3510AGQV

36V/1.2A Module Synchronous Step-Down Converter with Integrated Inductor
MPS

MPM3515

36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS

MPM3515GQV

36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS

MPM3515GQV-AEC1

36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS

MPM3515GQVE-AEC1

36V, 1.5A Module, Synchronous, Step-Down Converter with an Integrated Inductor AEC-Q100 Qualified
MPS

MPM3530GRF

Switching Regulator,
MPS

MPM3570E

Ultra Low EMI, 75V Input, 0.3A Step-Down Power Module with Integrated Inductor
MPS