Housing material: Flame-resistant resin (black)  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
INSTALLATION  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
LIGHTNING SURGE PROTECTOR FOR  
SELF-SYNCH USE  
Functions & Features  
Weight: 100 g (0.22 lb), standard; 125 g (0.28 lb), with DIN  
rail mounting adapter  
• Designed specifically for self-synchronizing motor circuit  
• Protects self-synch transmitter and converter from  
damage caused by surges on the wiring  
• Absorbs surges only without affecting instrumentation  
signal  
PERFORMANCE  
Max. continuous operating voltage (Uc):  
A to B to C: ±170 V  
• No interruption of signal by unplugging the protector  
element  
Line to earth: ±290 V  
Voltage protection level (Up):  
• @ 1 kV (100 A)  
1 to 2 to 3: ±350 V  
Line to earth: ±650 V  
Lot.NO  
• @ 2 kV (1 kA)  
MDEIJPAN1430B  
1 to 2 to 3: ±450 V  
M•STER  
MODEL  
Line to earth: ±800 V  
Response time: ≤ 0.1 μsec.  
Leakage current:  
A to B to C: ≤ 50 μA @ ±170 V DC  
Line to earth: ≤ 50 μA @ ±290 V DC  
Max. discharge current (Imax): 5000 A (8 / 20 μs)  
MODEL: MDP–JS[1]  
ORDERING INFORMATION  
• Code number: MDP-JS[1]  
Specify a code from below for [1].  
(e.g. MDP-JS/A33/Q)  
Nominal current (I ): 500 mA  
N
Internal series resistance: Approx. 2 Ω (per wire)  
Rated line voltage: 90 V AC  
Capacitance @ 1 MHz:  
• Specify the specification for option code /Q  
(e.g. /C01)  
Line to line: ≤ 1.5 nF  
Line to earth: ≤ 50 pF  
Surge protection: IEC 61643-21 Categories C1, C2, D1  
[1] OPTIONS (multiple selections)  
DIN Rail Mounting Adapter  
blank: Without  
/A33: With adapter (model A-33)  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M4 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel  
MDP-JS SPECIFICATIONS  
ES-8132 Rev.11 Page 1/4  
http://www.m-system.co.jp/  
MODEL: MDP-JS  
CONNECTION EXAMPLES  
SELF-SYNCH XMTR  
MDP-JS  
MDP-JS  
S1  
S2  
S3  
+
1
A
B
C
A
1
2
3
S1  
OUTPUT  
SELF-  
(PROTECTED EQUIPMENT)  
SYNCH  
2
3
B
C
S2 INPUT  
S3  
R2  
R1  
POWER  
G
G
U
V
(PROTECTED  
EQUIPMENT)  
SURGE PROTECTOR  
FOR POWER SUPPLY  
SURGE PROTECTOR  
FOR POWER SUPPLY  
u
v
U
V
U
V
u
v
G
G
POWER  
GROUNDING  
PROTECTED  
EQUIPMENT  
M-RESTER  
G
G
GROUNDING  
(100 ohms or less)  
CROSSOVER WIRE  
A crossover wire between M-RESTER ground and the ground or  
metallic housing of the equipment is required for protection.  
If the protected equipment has no ground terminal, ground the  
M-RESTER only.  
When the M-RESTER is mounted with DIN Rail Mounting Adapter,  
connect the grounding wire to the mounting screw of the M-RESTER.  
MDP-JS SPECIFICATIONS  
ES-8132 Rev.11 Page 2/4  
http://www.m-system.co.jp/  
MODEL: MDP-JS  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
STANDARD  
80 (3.15)  
53 (2.09)  
2–5 (.20) dia.  
MTG HOLE  
31.5 (1.24)  
27 (1.06)  
HEAD ELEMENT  
3
2
1
BASE  
6–M4 TERMINAL SCREW  
C
B
A
GROUND TERMINAL (G)  
(used as mounting bracket)  
WITH DIN RAIL MOUNTING ADAPTER  
8.5  
(.33)  
[3.3 (.13)]  
80 (3.15)  
53 (2.09)  
27 (1.06)  
31.5 (1.24)  
DIN RAIL  
35mm wide  
3
2
1
6–M4 TERMINAL SCREW  
C
B
A
2–M4 MOUNTING SCREW  
(used as ground terminal (G))  
MOUNTING REQUIREMENTS unit: mm (inch)  
2–M4 SCREW  
33 (1.30) min.  
MDP-JS SPECIFICATIONS  
ES-8132 Rev.11 Page 3/4  
http://www.m-system.co.jp/  
MODEL: MDP-JS  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
2Ω  
A
B
1
2
2Ω  
CABLE  
SIDE  
ELEMENT  
EQUIP.  
SIDE  
U
Discharge  
Elements  
Volt.  
Limiter  
C
3
2Ω  
BASE  
G
GROUND TERMINAL  
(used as mounting attachment)  
Specifications are subject to change without notice.  
MDP-JS SPECIFICATIONS  
ES-8132 Rev.11 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

MDP-JS/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LC

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LC/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LC/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LWA

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LWA/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-LWA/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-MFA

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-MFA/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-MFA/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-PA

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-PA/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM