R8-NC3-R/Q [MSYSTEM]

Remote I/O R8 Series POWER/NETWORK MODULE;
R8-NC3-R/Q
型号: R8-NC3-R/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R8 Series POWER/NETWORK MODULE

文件: 总5页 (文件大小:306K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R8-NC3  
Remote I/O R8 Series  
RELATED PRODUCTS  
• PC Configurator cable (model: COP-US)  
• PC configurator software (model: R8CFG)  
Downloadable at M-System’s web site.  
POWER/NETWORK MODULE  
(CC-Link Ver.2.00; for 64-point analog signals)  
Functions & Features  
• Free combination of analog and discrete I/O  
• Space-saving  
PACKAGE INCLUDES...  
• Protective cover  
Typical Applications  
GENERAL SPECIFICATIONS  
Connection  
• Remote I/O for DCS and PLC  
Power input: Tension clamp (Front Twin connection)  
Applicable wire size: 0.2 - 2.5 mm  
2
Stripped length: 10 mm  
•CC-Link: Tension clamp (Front Twin connection)  
Applicable wire size: 0.2 - 1.5 mm  
2
Stripped length: 10 mm  
Internal bus, intenal power, exc. supply: Via connector  
Max. number of I/O modules: 16  
(Max. consumption current of I/O modules: 1.6 A)  
Isolation: CC-Link to internal bus or internal power or power  
input to exc. supply to FE1  
MODEL: R8–NC3–R[1]  
Status indicators: Power, Run, Error, SD, RD  
Data allocation: Mode 1, 2  
ORDERING INFORMATION  
• Code number: R8-NC3-R[1]  
Specify a code from below for [1].  
(e.g. R8-NC3-R/Q)  
CC-Link COMMUNICATION  
Protocol: CC-Link. Conforms to Version 2.00  
Device type: Remote device station  
• Specify the specification for option code /Q  
(e.g. /C01)  
Required nodes: 4 (112 I/O points, 16 words) × m (m =  
Cyclic expansion setting)  
Network cable: CC-Link cable designated by Mitsubishi  
Electric  
I/O TYPE  
NC3: CC-Link  
Cyclic expansion: 2, 4 (Function selected with DIP SW)  
Station address setting: Rotary switch; 1 to 64  
Baud rate setting: Rotary switch  
POWER INPUT  
DC power  
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps  
Terminating resistor: Built-in (DIP Switch, default: disable)  
R: 24 V DC  
(Operational voltage range: ±10 %; ripple 10 %p-p max.)  
INSTALLATION  
Power consumption  
[1] OPTIONS  
blank: none  
DC: Approx. 12 W 24 V DC (@ internal power max. current  
1.6 A) )  
/Q: With options (specify the specification)  
Internal power supply (power supply for I/O module):  
• DC power supply: 5 V DC  
• Current capacity: 1.6 A  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Excitation supply output (excitation for I/O module)  
DC: 24 V DC ±10 %  
Operational current: 10 A  
/C02: Polyurethane coating  
(From power supply (exitation supply) connector, via  
connector for internal bus, supplied to each I/O module.  
Power output current consumption must be under  
R8-NC3 SPECIFICATIONS  
ES-9726 Rev.5 Page 1/5  
http://www.m-system.co.jp/  
MODEL: R8-NC3  
operational current.)  
Operating temperature: 0 to 55°C (32 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail  
Weight: 180 g (0.40 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute  
(CC-Link to internal bus or internal power or power input to  
exc. supply to FE1)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EN 50581  
EXTERNAL VIEW  
FRONT VIEW  
TOP VIEW  
Status Indicator LED  
Station Address Setting  
Rotary SW  
DA  
DG  
Baud Rate Setting  
Rotary SW  
DB  
SLD  
FE  
Internal Bus Connector  
CC-Link Connector  
Function Setting  
DIP SW  
Connector for  
Power Supply and  
Excitation Supply  
8
7
6
5
4
3
2
1
Terminator  
DIP SW  
On  
Miniature Jack Connector for Configuration  
STATUS INDICATOR LED  
ID  
COLOR FUNCTION  
ON when the internal 5V power is in normal  
status.  
Green ON with normal communication *1  
Red ON when abnormal data is received.  
Power Green  
Run  
Error  
SD  
Green ON with data transmitting  
Green ON with data receiving  
RD  
*1. Run LED turns off when no command is received from  
the master device.  
R8-NC3 SPECIFICATIONS  
ES-9726 Rev.5 Page 2/5  
http://www.m-system.co.jp/  
MODEL: R8-NC3  
CONNECTION DIAGRAMS  
MASTER CONNECTION  
MASTER UNIT  
R8-NC3  
R8-NC3  
TERMINATOR  
blue  
*1  
DA  
DB  
DA  
DB  
DA  
white  
yellow  
DB  
DG  
SLD  
FE  
DG  
SLD  
FG  
DG  
SLD  
FE  
*1. Turn on the terminator DIP switch to activate the internal terminating resistor.  
POWER SUPPLY, EXCITATION SUPPLY CONNECTOR TERMINAL ASSIGNMENT  
Printed-circuit board connector (Phoenix Contact)  
Unit side connector: MSTBV2,5/5-GF-5,08AU  
Cable side connector: TFKC2,5/5-STF-5,08AU  
PIN  
ID  
FUNCTION  
1
2
3
4
5
No.  
1
24V Power supply 24V DC  
2
0V  
+
Power supply 0V DC  
3
Excitation supply 24V DC  
Excitation supply 0V DC  
4
5
FE1 Grounding  
NETWORK CONNECTOR ASSIGNMENT  
Printed-circuit board connector (Phoenix Contact)  
Unit side connector:  
MC1,5/5-GF-3,5  
Cable side connector: TFMC1,5/5-STF-3,5  
PIN  
ID  
FUNCTION  
DA  
1
2
3
4
5
No.  
1
DA  
DG  
DB  
2
DG  
DB  
3
4
SLD Shield  
FE  
Functional earth  
5
R8-NC3 SPECIFICATIONS  
ES-9726 Rev.5 Page 3/5  
http://www.m-system.co.jp/  
MODEL: R8-NC3  
EXTERNAL DIMENSIONS unit: mm (inch)  
■UNIT  
50 (1.97)  
[3 (.12)]  
55 (2.17)  
[4 (.16)]  
DIN RAIL  
(35 mm wide)  
■PROTECTIVE COVER  
5 (.20)  
50 (1.97)  
R8-NC3 SPECIFICATIONS  
ES-9726 Rev.5 Page 4/5  
http://www.m-system.co.jp/  
MODEL: R8-NC3  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Note: In order to improve EMC performance, bond the FE1 terminal to ground.  
Caution: FE1 terminal is NOT a protective conductor terminal.  
STATUS  
INDICATOR  
ROTARY SW  
DIP SW  
Isolation  
Control  
Circuit  
Comm.  
Circuit  
DA  
DG  
DB  
INTERNAL BUS  
TO OTHER  
CC-Link  
DEVICES  
SLD  
FE  
JACK  
PC CONFIGURATION JACK  
+24V  
Power  
Circuit  
(No isolation)  
INTERNAL  
POWER (5V)  
POWER  
0V  
+
EXC. SUPPLY (24V)  
EXC. SUPPLY  
FE1  
Specifications are subject to change without notice.  
R8-NC3 SPECIFICATIONS  
ES-9726 Rev.5 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

R8-NEIP-R

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NEIP-R/Q

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NEIP1

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1-R

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1-R/Q

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-PA4

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM

R8-PA4A

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM

R8-PA4A/Q

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM

R8-PA4B

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM

R8-PA4B/Q

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM

R8-PA4C

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM