PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Features  
Description  
Using external 32.768kHz quartz crystal  
The PT7C4363 serial real-time clock is a low-power  
clock/calendar with a programmable square-wave output.  
Supports I2C-Bus's high speed mode (400 kHz)  
Includes time (Hour/Minute/Second) and calendar  
(Year/Month/Date/Day) counter functions (BCD  
code)  
Address and data are transferred serially via a 2-wire  
bidirectional bus. The clock/calendar provides seconds,  
minutes, hours, day, date, month, and year information.  
The date at the end of the month is automatically  
adjusted for months with fewer than 31 days, including  
corrections for leap year. The clock operates in the 24-  
hour format indicator.  
Programmable square wave output signal  
Oscillator stop flag  
Low backup current: typ. 500nA at VDD=3.0V and  
TA=25°C  
Operating range: 1.8V to 5.5V  
Table 1 shows the basic functions of PT7C4363. More  
details are shown in section: overview of functions.  
Ordering Information  
Part Number  
Package  
8-Pin DIP  
8-Pin SOIC  
PT7C4363P  
PT7C4363W  
Note: Lead free package is available by adding “E” after each  
part number. For example: PT7C4363PE.  
Table 1. Basic functions of PT7C4363  
Item  
Function  
PT7C4363  
Source: Crystal: 32.768kHz  
Oscillator enable/disable  
Oscillator fail detect  
1
Oscillator  
-
12-hour  
Time display  
-
24-hour  
2
Time  
Century bit  
Time count chain enable/disable  
Alarm interrupt  
3
4
Interrupt  
Timer interrupt output  
Programmable square wave output (Hz)  
1, 32, 1.024k, 32.768k  
2-wire I2C bus  
-
Communicat  
3-wire bus  
ion  
5
6
Burst mode  
-
Write protection  
-
Control  
External clock test mode  
Power-on reset override  
PT0207(07/05)  
Ver: 0  
1
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Function Block  
Alarm Register  
PT7C4363  
Comparator  
Timer  
(Min, Hour, Day, Date)  
X1  
X2  
CD  
Time Counter  
(Sec,Min,Hour,Day,Date,Month,Year)  
32.768  
kHz  
OSC  
Counter Chain  
CG  
Address  
Decoder  
Address  
Register  
I /O  
Control Register  
SCL  
SDA  
Interface  
(I2C)  
INT  
SQW  
Timer / Alarm Interrupt Control  
Square Wave Output Control  
Shift Register  
Note: PT7C4363 need to add a 10pF ~ 30pF capacitor between X1 and GND to get the accurate 32k frequency.  
Recommended Layout for Crystal  
PT7C4363  
X1  
X2  
32.768kHz  
Crystal  
Local Ground plane  
Layer 2  
Guard Ring  
(connect to gound)  
Crystal Specifications  
Parameter  
Symbol  
fO  
ESR  
CL  
Min  
Typ  
32.768  
Max  
40  
Unit  
kHz  
k  
Nominal Frequency  
Series Resistance  
Load Capacitance  
10  
pF  
The crystal, traces and crystal input pins should be isolated from RF generating signals.  
PT0207(07/05)  
Ver: 0  
2
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Pin Configuration  
PT7C4363  
8
1
X1  
VCC  
7
6
5
2
3
4
X2  
SQW  
SCL  
INT  
SDA  
GND  
DIP-8  
SOIC-8  
Pin Description  
Pin no.  
Pin  
Type  
Description  
1
X1  
I
Oscillator Circuit Input. Together with X2, 32.768kHz crystal is connected between them.  
Oscillator Circuit Output. Together with X1, 32.768kHz crystal is connected between them.  
Interrupt Output. Open drain, active low.  
2
3
4
X2  
O
O
P
INT  
GND  
Ground.  
Serial Data Input/Output. SDA is the input/output pin for the 2-wire serial interface. The  
SDA pin is open-drain output and requires an external pull-up resistor.  
5
6
SDA  
SCL  
I/O  
I
Serial Clock Input. SCL is used to synchronize data movement on the I2C serial interface.  
Clock Output. Open drain. Four frequencies selectable: 32.768k, 1.024k, 32, 1Hz when  
SQWE bit is set to 1.  
7
8
SQW  
VCC  
O
P
Power.  
PT0207(07/05)  
Ver: 0  
3
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Function Description  
Overview of Functions  
1. Clock function  
CPU can read or write data including the year (last two digits), month, date, day, hour, minute, and second. Any (two-digit) year  
that is a multiple of 4 is treated as a leap year and calculated automatically as such until the year 2100.  
2. Alarm function  
These devices have one alarm system that outputs interrupt signals from INTA for PT7C4363 or INT/OUT/SQW for PT7C4341  
to CPU when the date, day of the week, hour, minute or second correspond to the setting. Each of them may output interrupt  
signal separately at a specified time. The alarm may be selectable between on and off for matching alarm or repeating alarm.  
3. Programmable square wave output  
A square wave output enable bit controls square wave output at pin 7. 4 frequencies are selectable: 1, 32, 1.024k, 32.768k Hz.  
4. Interface with CPU  
Data is read and written via the I2C bus interface using two signal lines: SCL (clock) and SDA (data).  
Since the output of the I/O pin SDA is open drain, a pull-up resistor should be used on the circuit board if the CPU output I/O is  
also open drain.  
The SCL's maximum clock frequency is 400 kHz, which supports the I2C bus's high-speed mode.  
5. Oscillator fail detect  
When oscillator fail, OSF bit will be set.  
6. Oscillator enable/disable  
Only time count chain can be enable or disable by STOP bit..  
7. Timer function  
The timer control register determines one of 4 source clock frequencies for the timer (4096 Hz, 64 Hz, 1 Hz, or 1/60 Hz) and  
enables or disables the timer. The timer counts down from software loaded 8-bit binary value. At the end of every countdown, the  
timer sets the Timer Flag (TF). The TF may only be cleared by software. The asserted TF can be used to generate an interrupt.  
The interrupt may be generated as a pulsed signal every countdown period or as a permanently active signal which follows the  
condition of TF. Bit TI/TP is used to control this mode selection. When reading the timer, the current countdown value is returned.  
8. Reset function  
The PT7C4363 includes an internal reset circuit which is active whenever the oscillator is stopped. In the reset state the I2C-bus  
logic is initialized and all registers, including the address pointer, are cleared with the exception of bits FE, OSF, TD1, TD0,  
TESTC and AE which are set to logic 1.  
PT0207(07/05)  
Ver: 0  
4
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Registers  
1. Allocation of registers  
Register definition  
Addr.  
Function (time range  
BCD format)  
(hex) *1  
Bit 7  
Bit 6  
Bit 5  
STOP*3  
-
Bit 4  
-
Bit 3  
TESTC*4  
AF*6  
S8  
Bit 2  
-
Bit 1  
-
Bit 0  
-
TEST1*  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
Control/status 1  
Control/status 2  
Seconds (00-59)  
Minutes (00-59)  
Hours (00-23)  
-
-
2
-
OSF*8  
×
TI/TP*5  
S10  
M10  
H10  
D10  
×
TF*6  
S4  
AIE*7  
S2  
TIE*7  
S1  
S40  
M40  
×
S20  
M20  
H20  
D20  
×
M8  
H8  
M4  
H4  
D4  
W4  
MO4  
Y4  
M4  
H4  
D4  
W4  
×
M2  
H2  
M1  
H1  
×
Dates (01-31)  
D8  
D2  
D1  
×
×
Days of the week (00-06)  
Months (01-12)  
Years (00-99)  
W2  
MO2  
Y2  
W1  
MO1  
Y1  
×
×
×
Century  
Y80  
AE*9  
AE*9  
AE*9  
AE*9  
SQWE  
TE*10  
MO10  
Y10  
M10  
H10  
D10  
×
MO8  
Y8  
×
×
Y40  
M40  
×
Y20  
M20  
H20  
D20  
×
Alarm: Minutes (00-59)  
Alarm: Hours (01-12)  
Alarm: Dates (01-31)  
Alarm: Weekday (00-06)  
SQW control  
M8  
H8  
M2  
H2  
M1  
H1  
D8  
D2  
D1  
×
W2  
RS1  
TD1*11  
W1  
RS0  
TD0*11  
×
×
×
×
×
×
Timer control  
×
×
×
×
×
Timer  
Timer count down value  
Caution points:  
*1. PT7C4363 uses 8 bits for address. For excess 0FH address, PT7C4363 will not respond.  
*2. EXT_CLK test mode select bit.  
*3. When the bit is logic 1, time count chain stops but oscillator still runs.  
*4. Power-on reset override enable bit.  
*5. Timer interrupt output select bit.  
*6. Alarm and timer interrupt flag bits.  
*7. Alarm and timer interrupt enable bits.  
*8. Oscillator fail indicates. Indicate clock integrity.  
*9. Alarm enable bit. Alarm will be active when related time is matching if AE = 0.  
*10. Timer enable bit.  
*11. Timer source clock frequency select.  
*12. All bits marked with "×" are not implemented. All bits marked with "-" are not used bits and should always be written with  
logic 0. If read them, they could be logic 0 or 1.  
PT0207(07/05)  
Ver: 0  
5
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
2. Control and status register  
Addr.  
Description  
D7  
D6  
D5  
D4  
D3  
D2  
-
D1  
-
D0  
-
(hex)  
Control/status 1  
(default)  
TEST1  
0
-
STOP  
0
-
TESTC  
1
00  
Undefined  
Undefined  
Undefined Undefined Undefined  
Control/status 2  
(default)  
-
-
-
TI/TP  
0
AF  
TF  
AIE  
0
TIE  
0
01  
0D  
0E  
0F  
Undefined Undefined Undefined  
Undefined Undefined  
SQW control  
(default)  
SQWE  
1
×
×
×
×
×
RS1  
0
RS0  
0
Undefined Undefined Undefined Undefined Undefined  
Timer control  
(default)  
TE  
0
×
×
×
×
×
TD1  
1
TD0  
1
Undefined Undefined Undefined Undefined Undefined  
Timer  
Timer count down value  
Undefined  
(default)  
a) Timer  
TE: Timer Enable bit.  
TE  
Data  
Description  
Default  
0
1
Timer disabled  
Timer enabled  
Read / Write  
TD1, TD0: timer source clock frequency select. These bits determine the source clock for the countdown timer.  
TD1, TD0  
Data  
Timer source clock freq. (Hz)  
00  
4.096k  
64  
01  
Read / Write  
10  
1
When not in use, TD1 TD0 should be set to 11 for power saving.  
11  
1/60  
Timer:  
Timer  
Data  
Description  
Countdown Period = n / Source Clock Frequency  
Read / Write  
00~FF  
Count down value (n)  
For example: If TE = 1, TD1 TD0 = 10, Timer = 03 are written into PT7C4363, timer counts down every 1 second from 03 to 01  
then 03 cycled.  
PT0207(07/05)  
Ver: 0  
6
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
b) Timer Interrupt  
TIE: Timer Interrupt Enable bit.  
TIE  
Data  
Description  
Default  
0
1
Timer interrupt disabled  
Timer interrupt enabled  
Read / Write  
TF: Timer Flag  
TF  
Data  
Description  
0
1
0
1
Timer flag inactive  
Read  
Timer flag active. At the end of a timer countdown, TF is set to 1.  
Timer flag is cleared  
Write  
Timer flag remains unchanged  
TI/TP: Timer Interrupt output select  
TI/TP  
Data  
Description  
0
INT is active when TF is active (subject to the status of TIE)  
INT pulses active according to source clock frequency and timer count down value (subject to  
the status of TIE).  
INT negative pulse width (s)  
Source clock  
(Hz)  
n = 1  
n > 1  
1
1
4096  
64  
1
/
/
8192  
4096  
Read / Write  
1
1
/
/
128  
64  
1
1
1
/
/
64  
64  
1
1
1/60  
/
/
64  
64  
Note: TF and INT become active simultaneously.  
n = loaded countdown value. Timer stopped when n = 0.  
Example 1: If TE = 1, TD1 TD0 = 00, Timer = 03, TIE = 1, TF = 0, TI/TP = 1 are written into PT7C4363, timer register counts  
down every 1/4.096kHz seconds from 03 to 01 then 03 cycled and INT output negative pulse with 1/4096 seconds width. See Fig.1.  
4.096kHz internal clock  
Timer=02  
Timer=01  
Timer=03  
Set TF=1  
Timer=02  
Timer=01  
Timer=03  
INT  
Fig.1 Example 1 of timer interrupts  
PT0207(07/05)  
Ver: 0  
7
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Example 2: If TE = 1, TD1 TD0 = 10, Timer = 03, TIE = 1, TF = 0, TI/TP = 1 are written into PT7C4363, timer counts down  
every 1/4.096kHz seconds from 03 to 01 then 03 cycled and INT output negative pulse with 1/64 seconds width. See Fig.2.  
1Hz internal clock  
Timer=02  
Timer=01  
Timer=03  
Set TF=1  
Timer=02  
1/64  
INT  
Fig.2 Example 2 of timer interrupts  
c) Alarm Interrupt  
AIE: Alarm Interrupt Enable bit.  
AIE  
Data  
Description  
Description  
Default  
0
1
Alarm interrupt disabled  
Alarm interrupt enabled  
Read / Write  
AF: Alarm Flag  
AF  
Data  
0
1
0
1
Alarm flag inactive  
Read  
Alarm flag active  
Alarm flag is cleared  
Alarm flag remains unchanged  
Write  
d) SQW control  
SQWE: SQW output clock enable bit.  
SQWE  
Data  
Description  
0
1
the SQW output is inhibited and SQW output is set to high-impedance  
the SQW output is activated  
Read / Write  
Default  
Default  
RS1, RS0: SQW output frequency select.  
RS1, RS0  
Data  
SQW output freq. (Hz)  
00  
32.768k  
1.024k  
32  
01  
Read / Write  
10  
11  
1
PT0207(07/05)  
Ver: 0  
8
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
e) Time count  
STOP  
STOP  
Data  
0
Description  
Default  
RTC source clock runs.  
Read / Write  
All RTC divider chain flip-flops are asynchronously set to logic 0; the RTC clock is stopped  
(SQW at 32.768 kHz is still available)  
1
f) Test  
TEST1  
TEST1  
Data  
Description  
Default  
0
1
Normal mode.  
Read / Write  
EXT_CLK test mode.  
TESTC  
TESTC  
Data  
Description  
0
1
Power-on reset override facility is disabled; set to logic 0 for normal operation.  
Power-on reset override may be enabled  
Read / Write  
Default  
3. Time Counter  
Time digit display (in BCD code):  
Second digits: Range from 00 to 59 and carried to minute digits when incremented from 59 to 00.  
Minute digits: Range from 00 to 59 and carried to hour digits when incremented from 59 to 00.  
Hour digits: See description on the /12, 24 bit. Carried to day and day-of-the-week digits when incremented from 11 p.m. to  
12 a.m. or 23 to 00.  
Addr.  
(hex)  
Description  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Seconds  
(default)  
OSF*1  
1
S40  
S20  
S10  
S8  
S4  
S2  
S1  
02  
03  
04  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
M40 M20 M10 M8 M4 M2 M1  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
Minutes  
(default)  
×
0
Hours  
×
0
×
0
H20  
H10  
H8  
H4  
H2  
H1  
(default)  
Undefined Undefined Undefined Undefined Undefined Undefined  
*1 Note: Indicate clock integrity. When the bit is 1, the clock integrity is no longer guaranteed and the time need be adjusted.  
PT0207(07/05)  
Ver: 0  
9
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
4. Days of the week Counter  
The day counter is a divide-by-7 counter that counts from 00 to 06 and up 06 before starting again from 00. Values that  
correspond to the day of week are user defined but must be sequential (i.e., if 0 equals Sunday, then 1 equals Monday, and so on).  
Illogical time and date entries result in undefined operation.  
Addr.  
Description  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
(hex)  
Days of the week  
(default)  
×
0
×
0
×
0
×
0
×
0
W4  
W2  
W1  
06  
Undefined Undefined Undefined  
5. Calendar Counter  
The data format is BCD format.  
Day digits: Range from 1 to 31 (for January, March, May, July, August, October and December).  
Range from 1 to 30 (for April, June, September and November).  
Range from 1 to 29 (for February in leap years).  
Range from 1 to 28 (for February in ordinary years).  
Carried to month digits when cycled to 1.  
Month digits: Range from 1 to 12 and carried to year digits when cycled to 1.  
Year digits: Range from 00 to 99 and 00, 04, 08, … , 92 and 96 are counted as leap years.  
Addr.  
(hex)  
Description  
D7  
D6  
D5  
D4  
D3  
D8  
D2  
D4  
D1  
D2  
D0  
D1  
Dates  
×
0
×
0
D20  
D10  
05  
07  
08  
(default)  
Undefined Undefined Undefined Undefined Undefined Undefined  
Months  
Century*1  
Undefined  
×
0
×
0
M10  
Undefined Undefined Undefined Undefined Undefined  
Y10 Y8 Y4 Y2 Y1  
M8  
M4  
M2  
M1  
(default)  
Years  
Y80  
Y40  
Y20  
(default)  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
*1: The century bit is toggled when the years register overflows from 99 to 00.  
6. Alarm Register  
PT7C4363: Alarm Register  
Addr.  
Description  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Alarm: Minutes  
(default)  
AE*1  
M40  
M20  
M10  
M8  
M4  
M2  
M1  
09  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
Alarm: Hours  
(default)  
AE*2  
H20  
Undefined Undefined Undefined Undefined Undefined Undefined  
D20 D10 D8 D4 D2 D1  
Undefined Undefined Undefined Undefined Undefined Undefined  
H10  
H8  
H4  
H2  
H1  
×
0A  
0B  
0C  
Undefined  
AE*3  
0
Alarm: Dates  
(default)  
×
0
Undefined  
AE*4  
Alarm: Weekday  
(default)  
W4  
W2  
W1  
×
×
×
×
Undefined  
0
0
0
0
Undefined Undefined Undefined  
*1 Note: Minute alarm enable bit.  
*2 Note: Hour alarm enable bit.  
*3 Note: Date alarm enable bit.  
*4 Note: Weekday alarm enable bit.  
PT0207(07/05)  
Ver: 0  
10  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Alarm Function  
Related register  
Register definition  
Function  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
TF  
Bit 1  
AIE  
Bit 0  
TIE  
01  
02  
03  
04  
05  
06  
09  
0A  
0B  
0C  
Control/status 2  
Seconds  
-
-
-
TI/TP  
AF  
OSF  
×
S40  
M40  
×
S20  
M20  
H20  
D20  
×
S10  
M10  
H10  
D10  
×
S8  
M8  
H8  
D8  
×
S4  
M4  
H4  
D4  
W4  
M4  
H4  
D4  
S2  
M2  
H2  
D2  
W2  
M2  
H2  
D2  
W2  
S1  
M1  
H1  
D1  
W1  
M1  
H1  
D1  
W1  
Minutes  
Hours  
×
Dates  
×
×
Days of the week  
Alarm: Minutes  
Alarm: Hours  
Alarm: Dates  
Alarm: Weekday  
×
×
AE  
M40  
×
M20  
H20  
D20  
×
M10  
H10  
D10  
×
M8  
H8  
D8  
×
AE  
AE  
AE  
×
×
W4  
When one or more of these registers are loaded with a valid minute, hour, day or weekday and its corresponding bit Alarm Enable  
(AE) is logic 0, then that information will be compared with the current minute, hour, day and weekday. When all enabled  
comparisons first match, the Alarm Flag (AF) is set. AF will remain set until cleared by software. Once AF has been cleared it  
will only be set again when the time increments to match the alarm condition once more. Alarm registers which have their bit AE  
at logic 1 will be ignored.  
EXT_CLK Test Mode and POR override  
1. EXT_CLK Test Mode  
A test mode is available which allows for on-board testing. In such a mode it is possible to set up test conditions and control the  
operation of the RTC. The test mode is entered by setting bit TEST1 in control/status1 register. Then pin SQW becomes an input.  
The test mode replaces the internal 64 Hz signal with the signal applied to pin SQW. Every 64 positive edges applied to pin SQW  
will then generate an increment of one second.  
The signal applied to pin SQW should have a minimum pulse width of 300 ns and a minimum period of 1000 ns. The internal 64  
Hz clock, now sourced from SQW, is divided down to 1 Hz by a 26 divide chain called a pre-scaler. The pre-scaler can be set into  
a known state by using bit STOP. When bit STOP is set, the pre-scaler is  
reset to 0 (STOP must be cleared before the pre-scaler can operate again).  
From a STOP condition, the first 1 second increment will take place after 32 positive edges on SQW. Thereafter, every 64 positive  
edges will cause a 1 second increment.  
Remark: Entry into EXT_CLK test mode is not synchronized to the internal 64 Hz clock. When entering the test mode, no  
assumption as to the state of the pre-scaler can be made.  
PT0207(07/05)  
Ver: 0  
11  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Operation example:  
1. Set EXT_CLK test mode (control/status 1, bit TEST1 = 1)  
2. Set STOP (control/status 1, bit STOP = 1)  
3. Clear STOP (control/status 1, bit STOP = 0)  
4. Set time registers to desired value  
5. Apply 32 clock pulses to SQW  
6. Read time registers to see the first change  
7. Apply 64 clock pulses to SQW  
8. Read time registers to see the second change.  
Repeat 7 and 8 for additional increments.  
2. Power-On Reset (POR) override  
The POR duration is directly related to the crystal oscillator start-up time. Due to the long start-up times experienced by these  
types of circuits, a mechanism has been built in to disable the POR and hence speed up on-board test of the device. The setting of  
this mode requires that the I2C-bus pins, SDA and SCL, be toggled in a specific order as shown in Fig 6.4.2. All timings are  
required minimums.  
Once the override mode has been entered, the device immediately stops being reset and normal operation may commence i.e.  
entry into the EXT_CLK test mode via I2C-bus access.  
The override mode may be cleared by writing a logic 0 to TESTC. TESTC must be set to logic 1 before re-entry into the override  
mode is possible. Setting TESTC to logic 0 during normal operation has no effect except to prevent from entering the POR  
override mode.  
Power up  
Override active  
Fig.3 POR override sequence  
PT0207(07/05)  
Ver: 0  
12  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Communication  
1. I2C Bus Interface  
a) Overview of I2C-BUS  
The I2C bus supports bi-directional communications via two signal lines: the SDA (data) line and SCL (clock) line. A combination  
of these two signals is used to transmit and receive communication start/stop signals, data signals, acknowledge signals, and so on.  
Both the SCL and SDA signals are held at high level whenever communications are not being performed. The starting and  
stopping of communications is controlled at the rising edge or falling edge of SDA while SCL is at high level. During data  
transfers, data changes that occur on the SDA line are performed while the SCL line is at low level, and on the receiving side the  
data is captured while the SCL line is at high level. In either case, the data is transferred via the SCL line at a rate of one bit per  
clock pulse. The I2C bus device does not include a chip select pin such as is found in ordinary logic devices. Instead of using a  
chip select pin, slave addresses are allocated to each device and the receiving device responds to communications only when its  
slave address matches the slave address in the received data.  
b) System Configuration  
All ports connected to the I2C bus must be either open drain or open collector ports in order to enable AND connections to  
multiple devices.  
SCL and SDA are both connected to the VDD line via a pull-up resistance. Consequently, SCL and SDA are both held at high  
level when the bus is released (when communication is not being performed).  
Vcc  
RP  
RP  
SDA  
SCL  
Master  
MCU  
Slave  
RTC  
Other Peripheral  
Device  
Note: When there is only one master, the MCU is ready for driving SCL to "H" and RP of SCL may not required.  
Fig.4 System configuration  
PT0207(07/05)  
Ver: 0  
13  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
c) Starting and Stopping I2C Bus Communications  
Fig.5 Starting and stopping on I2C bus  
START condition, repeated START condition, and STOP condition  
START condition  
SDA level changes from high to low while SCL is at high level  
STOP condition  
SDA level changes from low to high while SCL is at high level  
Repeated START condition (RESTART condition)  
In some cases, the START condition occurs between a previous START condition and the next STOP condition, in  
which case the second START condition is distinguished as a RESTART condition. Since the required status is the same as for the  
START condition, the SDA level changes from high to low while SCL is at high level.  
d) Data Transfers and Acknowledge Responses during I2C-BUS Communication  
Data transfers  
Data transfers are performed in 8-bit (1 byte) units once the START condition has occurred. There is no limit on the amount  
(bytes) of data that are transferred between the START condition and STOP condition.  
The address auto increment function operates during both write and read operations.  
Updating of data on the transmitter (transmitting side)'s SDA line is performed while the SCL line is at low level.  
The receiver (receiving side) captures data while the SCL line is at high level.  
*Note with caution that if the SDA data is changed while the SCL line is at high level, it will be treated as a START, RESTART,  
or STOP condition.  
PT0207(07/05)  
Ver: 0  
14  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Data acknowledge response (ACK signal)  
When transferring data, the receiver generates a confirmation response (ACK signal, low active) each time an 8-bit data segment  
is received. If there is no ACK signal from the receiver, it indicates that normal communication has not been established. (This  
does not include instances where the master device intentionally does not generate an ACK signal.)  
Immediately after the falling edge of the clock pulse corresponding to the 8th bit of data on the SCL line, the transmitter releases  
the SDA line and the receiver sets the SDA line to low (= acknowledge) level.  
SCL from Master  
8
9
2
1
SDA from transmitter  
(sending side)  
Release SDA  
Low active  
ACK signal  
SDA from receiver  
(receiving side)  
After transmitting the ACK signal, if the Master remains the receiver for transfer of the next byte, the SDA is released at the  
falling edge of the clock corresponding to the 9th bit of data on the SCL line. Data transfer resumes when the Master becomes the  
transmitter.  
When the Master is the receiver, if the Master does not send an ACK signal in response to the last byte sent from the slave, that  
indicates to the transmitter that data transfer has ended. At that point, the transmitter continues to release the SDA and awaits a  
STOP condition from the Master.  
e) Slave Address  
The I2C bus device does not include a chip select pin such as is found in ordinary logic devices. Instead of using a chip select pin,  
slave addresses are allocated to each device.  
All communications begin with transmitting the [START condition] + [slave address (+ R/W specification)]. The receiving device  
responds to this communication only when the specified slave address it has received matches its own slave address.  
Slave addresses have a fixed length of 7 bits. See table for the details.  
An R/W bit is added to each 7-bit slave address during 8-bit transfers.  
Slave address  
Operation  
Transfer data  
R / W bit  
bit 0  
bit 7  
1
bit 6  
0
bit 5  
1
bit 4  
0
bit 3  
0
bit 2  
0
bit 1  
1
Read  
A3 h  
A2 h  
1 (= Read)  
0 (= Write)  
Write  
2. I2C Bus’s Basic Transfer Format  
S
Start indication  
P
Stop indication  
A
A
RTC Acknowledge  
Sr  
Restart indication  
Master Acknowledge  
PT0207(07/05)  
Ver: 0  
15  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
a) Write via I2C bus  
Addr. setting  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
Slave address (7 bits)  
S
A
A
A
P
write  
0
7
6
5
4
3
2
1
0
1
0
1
0
0
0
1
Start  
Stop  
A
C
K
A
C
K
A
C
K
Slave address + write specification  
Write data  
Address  
Specifies the write start address.  
b) Read via I2C bus  
Standard read  
Slave address (7 bits)  
Addr. setting  
S
A
A
write  
1
0
1
0
0
0
1
0
Start  
A
C
K
A
C
K
Slave address + write specification  
Address  
Specifies the read start address.  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
/
A
Slave address (7 bits)  
Sr  
A
A
P
Read  
1
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
1
0
1
0
0
0
1
Restart  
A
C
K
A
C
K
Stop  
N
O
Data read (1)  
Data is read from the specified start  
address and address auto increment.  
Data read (2)  
Address auto increment to set the  
address for the next data to be read.  
Slave address + read specification  
A
C
K
Simplified read  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
bit  
/
A
Slave address (7 bits)  
S
A
A
P
Read  
1
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
1
0
1
0
0
0
1
Start  
A
C
K
A
C
K
Stop  
N
O
Data read (2)  
Data read (1)  
Slave address + read specification  
Address register auto increment to set  
the address for the next data to be  
read.  
Data is read from the address pointed  
by the internal address register and  
address auto increment.  
A
C
K
Note:  
1. The above steps are an example of transfers of one or two bytes only. There is no limit to the number of bytes transferred  
during actual communications.  
2. 49H, 4AH are used as test mode address. Customer should not use the addresses.  
PT0207(07/05)  
Ver: 0  
16  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Maximum Ratings  
o
o
Storage Temperature....................................................................................................................... -65 Cto +150 C  
o
o
Ambient Temperature with Power Applied........................................................................... -40 Cto +85 C  
Supply Voltage to Ground Potential (Vcc to GND) ..........................................................-0.3V to +6.5V  
DC Input (All Other Inputs except Vcc & GND)................................................................-0.3V to (Vcc+0.3V)  
DC Output Voltage (SDA, /INTA, /INTB pins).................................................................. -0.3V to +6.5V  
Power Dissipation............................................................................................................................ 320mW (Depend on package)  
Note:  
Stresses greater than those listed under MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and  
functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not  
implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability.  
Recommended Operating Conditions  
Symbol  
Description  
Min  
Type  
Max  
Unit  
V
VCC  
VIH  
VIL  
TA  
Power voltage  
1.8  
0.7 VCC  
-0.3  
-
-
-
-
5.5  
VCC+0.3  
0.3 VCC  
85  
Input high level  
Input low level  
Operating temperature  
-40  
ºC  
PT0207(07/05)  
Ver: 0  
17  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
DC Electrical Characteristics  
Unless otherwise specified, GND =0V, VCC = 1.8 ~ 5.5 V, TA = -40 °C to +85 °C, fOSC = 32.768kHz.  
Sym.  
Description  
Pin  
Conditions  
Min Typ  
Max Unit  
Interface inactive. TA = 25°C 1)  
Interface active. fSCL = 400kHz 1)  
1.0  
1.8  
5.5  
Supply voltage  
VCC  
5.5  
V
VCC  
Supply voltage for clock  
data integrity  
VCC  
1.0  
0.9  
fSCL = 400kHz  
fSCL = 100kHz  
VCC = 5.0V  
800  
µA  
Interface active  
200  
275  
250  
225  
500  
400  
400  
825  
550  
425  
950  
650  
500  
550  
TA = 25°C  
Interface  
nA  
nA  
nA  
nA  
VCC = 3.0V  
500  
450  
inactive (fSCL  
0Hz), pin 7  
disabled 2)  
=
VCC = 2.0V  
VCC = 5.0V  
VCC = 3.0V  
750  
TA = -40 ~  
85°C  
650  
ICC Supply current  
VCC  
VCC = 2.0V  
600  
VCC = 5.0V  
VCC = 3.0V  
1600  
1000  
800  
Interface  
TA = 25°C  
inactive (fSCL  
0Hz), pin 7  
enabled at  
32kHz 2)  
=
VCC = 2.0V  
VCC = 5.0V  
VCC = 3.0V  
VCC = 2.0V  
1700  
1100  
900  
TA = -40 ~  
85°C  
VIL1 Low-level input voltage  
SCL  
0
0.7VCC  
-3  
0.3VCC  
VCC  
V
VIH1 High-level input voltage SCL  
SDA  
VOL = 0.4V, VCC = 5V  
IOL Low-level output voltage  
mA  
/INT, SQW VOL = 0.4V, VCC = 5V  
SCL  
-1  
IIL Input leakage current  
±1  
±1  
µA  
µA  
IOZ Output current when OFF  
Note:  
1) For reliable oscillator start-up at power-up: VCC(min)power-up = VCC(min) + 0.3 V.  
2) Timer source clock = 1/60 Hz, voltage of SCL and SDA is VCC or GND.  
PT0207(07/05)  
Ver: 0  
18  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
AC Electrical Characteristics  
Sym  
VHM  
VHL  
Description  
Rising and falling threshold voltage high  
Rising and falling threshold voltage low  
Value  
0.8 VCC  
0.2 VCC  
Unit  
V
V
Signal  
VHM  
VLM  
tr  
tf  
Over the operating range  
Symbol  
Item  
Min.  
Typ.  
Max.  
Unit  
kHz  
µs  
fSCL  
SCL clock frequency  
400  
tSU;STA  
tHD;STA  
tSU;DAT  
tHD;DAT1  
tHD;DAT2  
tSU;STO  
tBUF  
START condition set-up time  
START condition hold time  
0.6  
0.6  
200  
35  
µs  
ns  
Data set-up time (RTC read/write)  
Data hold time (RTC write)  
Data hold time (RTC read)  
STOP condition setup time  
Bus idle time between a START and STOP condition  
When SCL = "L"  
ns  
0
µs  
0.6  
1.3  
1.3  
0.6  
µs  
µs  
tLOW  
tHIGH  
tr  
µs  
When SCL = "H"  
µs  
Rise time for SCL and SDA  
Fall time for SCL and SDA  
Allowable spike time on bus  
Capacitance load for each bus line  
0.3  
0.3  
50  
µs  
tf  
µs  
ns  
tSP*  
CB  
400  
pF  
* Note: Only reference for design.  
tSU;STA  
S
Sr  
P
SCL  
tLOW  
tHIGH  
tHD;STA  
tSP  
fSCL  
tBUF  
SDA  
tSU;DAT  
tHD;STA  
tSU;STO  
tHD;STA  
tHD;DAT  
tSU;STA  
S
P
Start condition  
Stop condition  
Sr  
Restart condition  
PT0207(07/05)  
Ver: 0  
19  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Mechanical Information  
P/PE PDIP-8  
8
.240  
.280  
6.09  
7.11  
1
.355  
7.62  
8.25  
.400  
9.01  
.300  
10.16  
.325  
.210  
Max  
5.33  
0O  
15o  
.008  
.014  
SEATING  
PLANE  
0.20  
0.35  
.430  
Max  
.015 Min 0.381  
.356  
10.92  
.115  
.150  
.100  
typical  
.014  
.022  
2.921  
3.81  
DENOTES DIMENSIONS  
IN MILLIMETERS  
X.XX  
X.XX  
.558  
2.54  
Note  
1) Controlling dimensions in inches.  
2) Ref: JDDEC MS-001 BA  
PT0207(07/05)  
Ver: 0  
20  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
W/WE SOIC-8  
8
.0099  
.0196  
x 45o  
0.25  
0.50  
.149  
.157  
3.78  
3.99  
0-8o  
0.19  
0.25  
.0075  
.0098  
.016  
.050  
0.40  
1.27  
1
.2284  
.189  
.196  
4.80  
5.00  
.2440  
5.80  
6.20  
.016  
.026  
0.406  
0.660  
1.35  
1.75  
.053  
.068  
DENOTES DIMENSIONS  
IN MILLIMETERS  
X.XX  
X.XX  
SEATING  
PLANE  
REF  
Note:  
1) Controlling dimensions in  
millimeters.  
2) Ref: JDDEC MS-012 AA  
.050  
BSC  
.0040  
.0098  
0.10  
0.25  
1.27  
.013  
.020  
0.330  
0.508  
PT0207(07/05)  
Ver: 0  
21  
Data Sheet  
PT7C4363  
Real-time Clock Module (I2C Bus)  
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||  
Notes  
Pericom Technology Inc.  
Email: support@pti.com.cnWeb Site: www.pti.com.cn, www.pti-ic.com  
China:  
No. 20 Building, 3/F, 481 Guiping Road, Shanghai, 200233, China  
Tel: (86)-21-6485 0576 Fax: (86)-21-6485 2181  
Asia Pacific: Unit 1517, 15/F, Chevalier Commercial Centre, 8 Wang Hoi Rd, Kowloon Bay, Hongkong  
Tel: (852)-2243 3660 Fax: (852)- 2243 3667  
U.S.A.:  
3545 North First Street, San Jose, California 95134, USA  
Tel: (1)-408-435 0800 Fax: (1)-408-435 1100  
Pericom Technology Incorporation reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or  
performance and to supply the best possible product. Pericom Technology does not assume any responsibility for use of any circuitry described other than the  
circuitry embodied in Pericom Technology product. The company makes no representations that circuitry described herein is free from patent infringement or other  
rights, of Pericom Technology Incorporation.  
PT0207(07/05)  
Ver: 0  
22  

相关型号:

PT7C4363WE

Real Time Clock, Non-Volatile, 1 Timer(s), CMOS, PDSO8, GREEN, MS-012E/AA, SOIC-8
PERICOM

PT7C4363WEX

Real Time Clock, Non-Volatile, 1 Timer(s), CMOS, PDSO8, GREEN, MS-012E/AA, SOIC-8
PERICOM

PT7C4372A

Real-time Clock Module
PERICOM

PT7C4372ALE

Real-time Clock Module
PERICOM

PT7C4372AWE

Real-time Clock Module
PERICOM

PT7C4372C

Real-time Clock Module
PERICOM

PT7C4372CLE

Real-time Clock Module
PERICOM

PT7C4372CWE

Real-time Clock Module
PERICOM

PT7C4501

Frequency Multiplier?
ETC

PT7C4502

PLL Clock Multiplier
PERICOM

PT7C4502-2WF

PLL Clock Multiplier
PERICOM

PT7C4502DE

PLL Clock Multiplier
PERICOM