MDU2-40-3AD [SLPOWER]
AC-DC Regulated Power Supply Module,;型号: | MDU2-40-3AD |
厂家: | SL Power Electronics |
描述: | AC-DC Regulated Power Supply Module, |
文件: | 总4页 (文件大小:464K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
40W
OPEN-FRAME SWITCHING POWER SUPPLIES
• Single, Dual and Triple Output Models
• Universal AC-Input and DC-Input Models
• CE Mark: UL/CSA/EN60950 Approvals
• BABT Approvals
• Austel CCL Certification
• Models with UL544/CSA C22.2-601/EN60-601
Medical Safety Approvals
• EN55022/FCC Class B Input Line Filter
• 0% Minimum Load Requirement
• Over-Current/Short-Circuit Protection
• 2-Year Warranty
• Minimum 200,000-Hour MTBF
CHARACTERISTICS
Output Current Output
Input Voltage.............................FLU and MDU models, universal
input range 85-265 VAC single
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Model
Output (V)
(A)
(A)
(A)
Tol. Reg. Reg. Reg.
phase or 100-370 VDC. DC-input
models, 36-75 VDC (48V, nominal).
AC-DC Singles
85-265 VAC Input
Input Line Frequency................47-440 Hz (ac input models).
Input Line Protection.................MOV transient protected (FLU and
MDU series). Input line fuse provid-
ed on-board. (See Note 1.)
EMI Filter...................................Standard. Performance surpasses
conducted EMI requirements of
FLU1-40-1AD
FLU1-40-2AD
FLU1-40-3AD
FLU1-40-4AD
FLU1-40-5AD
FLU1-40-6AD
V1
V1
V1
V1
V1
V1
5
0.0 8.00 8.00 1.0% 0.1% 0.2%
0.0 4.40 4.40 1.0% 0.1% 0.2%
0.0 3.30 3.30 1.0% 0.1% 0.2%
0.0 2.70 2.70 1.0% 0.1% 0.2%
0.0 1.70 1.70 1.0% 0.1% 0.2%
0.0 1.40 1.40 1.0% 0.1% 0.2%
—
—
—
—
—
—
9
12
15
24
28
EN55022/FCC Class B by 10 dB, typ.
DC Output.................................See table. (Note 2.)
Continuous Output Power.........40W, maximum.
Leakage Current .......................MDU Series, non-patient contact rat-
ing: 500 µA, maximum.
Output Voltage Adjust ...............Primary output adjustable ±5%.
Auxiliary outputs fixed.
Efficiency...................................62-75%, typical (nominal input line
voltage, nominal load conditions).
Hold-Up Time............................FLU and MDU models: 16 ms (115
VAC input), 32 ms (230 VAC input),
AC-DC Singles
MDU1-40-1AD V1
MDU1-40-2AD V1
MDU1-40-3AD V1
MDU1-40-4AD V1
MDU1-40-5AD V1
MDU1-40-6AD V1
To UL544/EN60-601/CSA 22.2-601.1
5
0.0 8.00 8.00 1.0% 0.1% 0.2%
0.0 4.40 4.40 1.0% 0.1% 0.2%
0.0 3.30 3.30 1.0% 0.1% 0.2%
0.0 2.70 2.70 1.0% 0.1% 0.2%
0.0 1.70 1.70 1.0% 0.1% 0.2%
0.0 1.40 1.40 1.0% 0.1% 0.2%
—
—
—
—
—
—
9
12
15
24
28
minimum, at full load
AC-DC Duals
85-265 VAC Input
Overload Protection ..................Power-limit circuit.
Short-Circuit Protection.............Continuous.
Over-Voltage Protection............Primary output only.
Soft Start...................................Standard on all models.
Design Topology .......................Flyback converter with current-mode
control.
Frequency of Operation............40 kHz (fixed).
Hi-Pot Isolation..........................FLU Series: 5300 VDC, input-to-out-
put for one minute. (Note 3.)
FLU2-40-1AD
FLU2-40-2AD
FLU2-40-3AD
FLU2-40-4AD
FLU2-40-5AD
FLU2-40-6AD
FLU2-40-7AD
V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
V2 +12
V1 +5
V2 +15
V1 +5
V2 +24
V1 +5
0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.70 2.00 5.0% 0.5% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.00 1.50 5.0% 0.5% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0%
0.0 6.00 6.00 1.0% 0.2% 1.0%
0.0 2.00 2.00 3.0% 0.5% 1.0% 1.0%
—
—
—
V2 +28
MDU Series: 5700 VDC, input-to-out-
put for one minute. (Note 3.)
V1 5(ISO)
V2 5(ISO)
—
Noise, Ripple and Spike ...........1% peak-to-peak, maximum. (See
Note 5.)
Temperature Range ..................-20°C to +70°C.
Output Power De-Rating...........De-rate output power and current
linearly 2%/°C from +50°C to +70°C.
V1 12(ISO) 0.0 2.00 3.00 1.0% 0.2% 1.0%
V2 12(ISO) 0.0 1.00 2.00 3.0% 0.5% 1.0% 1.0%
V1 15(ISO) 0.0 1.50 2.50 1.0% 0.2% 1.0%
V2 15(ISO) 0.0 1.20 2.00 3.0% 0.5% 1.0% 1.0%
—
—
Temperature Coefficient............±0.05%/°C over the entire operating
temperature range.
AC-DC Duals
To UL544/EN60-601/CSA 22.2-601.1
Relative Humidity......................0 to 95%, non-condensing.
Altitude......................................0 to 10,000 feet.
Cooling......................................Convection cooling is adequate.
Moving air is recommended for oper-
MDU2-40-1AD V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.70 2.00 5.0% 0.2% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.00 1.50 5.0% 0.2% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0
—
V2 +12
MDU2-40-2AD V1
+5
—
V2 +15
ation in a confined area.
MDU2-40-3AD V1
+5
—
Storage Temperature ................-40°C to +85°C.
Storage Humidity ......................0 to 95%, non-condensing.
Mean Time Between Failures ...>200,000 hours. (Note 6.)
V2 +24
MDU2-40-4AD V1
+5
—
V2 +28
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
08
40W
OPEN-FRAME SWITCHING POWER SUPPLIES
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output (V) (A) (A) (A) Tol. Reg. Reg. Reg.
Model
Output (V)
(A)
(A)
(A)
Tol. Reg. Reg. Reg.
Model
DC-DC Duals
36-75 VDC Input
AC-DC Triples
To UL544/EN60-601/CSA 22.2-601.1
DC2-40-1AC
DC2-40-2AC
DC2-40-3AC
DC2-40-4AC
V1
V2 +12
V1 +5
V2 +15
V1 +5
V2 +24
V1 +5
V2 +28
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.70 2.00 5.0% 0.2% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
0.0 1.00 1.50 5.0% 0.2% 3.0% 4.0%
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
*
MDU3-40-1AD V2 +12
V3 -12
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
—
V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
*
MDU3-40-2AD V2 +12
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0%
—
V3
V1
-5
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
—
MDU3-40-3AD V2 +15
V3 -15
0.0 1.20 2.00† 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0%
0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0%
AC-DC Triples
85-265 VAC Input
V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
V1
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
MDU3-40-4AD V2 +24
V3 -12
0.0 0.75 1.50§ 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
*
FLU3-40-1AD
FLU3-40-2AD
FLU3-40-3AD
FLU3-40-4AD
FLU3-40-5AD
FLU3-40-6AD
V2 +12
V3 -12
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
DC-DC Triples
36-75 VDC Input
0.0 3.00 5.00 1.0% 0.2% 1.0%
V1
V2 +12
V3
V1
V2 +15
V3 -15
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
V1
V2 +12
V3 -12
+5
—
*
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0%
*
DC3-40-1AC
DC3-40-2AC
DC3-40-3AC
DC3-40-4AC
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
-5
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
0.0 1.20 2.00† 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0%
V1
V2 +12
V3
V1
V2 +15
V3 -15
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
*
0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0%
0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0%
-5
V1
V2 +24
V3 -12
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
0.0 0.75 1.50§ 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
0.0 1.20 2.00† 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0%
V1 5(ISO)
0.0 5.00 6.00 1.0% 0.2% 0.5%
—
V1
V2 +24
V3 -12
+5
0.0 3.00 5.00 1.0% 0.2% 1.0%
—
V2 12(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0%
V3 12(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0%
0.0 0.75 1.50§ 5.0% 1.0% 3.0% 4.0%
0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0%
V1 5(ISO)
0.0 5.00 6.00 1.0% 0.2% 0.5%
—
V2 15(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0%
V3 15(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0%
* Peak output current rating = 5.0A (<60 seconds, duty cycle <10%).
† Peak output current rating = 3.0A (<60 seconds, duty cycle <10%).
§ Peak output current rating = 2.0A (<60 seconds, duty cycle <10%).
Notes
Model Selection Guide
1. Replace the input line fuse with the same type and rating.
Recommended: 2A/250V slow-blow fuse.
FLU 2 - 40 - 1 A D
2. The sum of primary and auxiliary output currents from triple
output models -1AD through -4AD must not exceed 5.0A.
Input Voltage
D=85-265 VAC
C=36 to 75 VDC
Series
FLU=AC Input
MDU=AC Input
3. Hi-pot isolation is 2200 VDC from the input of the supply to
ground for 60 seconds.
(UL544/IEC601 Safety)
DC=DC Input
Construction
A=Open PCB
B=L-Bracket
4. All measurements are made directly at the terminals of the
power supply.
Number of Outputs
Output Power (W)
5. Peak-to-peak and RMS metering equipment must have a 20
MHz frequency response with probes and cables that main-
tain a frequency response of 20 Hz to 20 MHz. Output rip-
ple and spikes are measured directly at the output terminals
of the power supply with a 0.1 µF ceramic capacitor. The
probe ground band must make direct contact with the output
return or common terminal to prevent erroneous noise mea-
surements.
C=Full Enclosure
Output Voltage (Model)
of nominal load; load current is then varied +40%/-30% of nominal while other outputs
are held at nominal load conditions.
10. Cross-regulation is tested by changing the load on the primary output from 50% to
100% of nominal load while measuring the voltage change on the auxiliary output
under test.
6. MTBF is calculated using the parts stress method in MIL-
HDBK 217F (ground benign, TA = +25°C).
7. Output voltage tolerance is measured under nominal load
current conditions.
11. The FLU1-40, FLU2-40 and FLU3-40 series are approved to UL1950 (File E140439),
CSA22.2 No. 234 (File LR52335), EN60950/IEC950/DIN VDE 0805 (TÜV Licenses
R679206, R0097621, R9071501), and Austel CCL (Certificate A92/PS/004).
12. The FLU3-40 series has BABT/EN41003 approval ((NS/4199/123/R/604674).
13. The MDU1-40, MDU2-40 and MDU3-40 series are approved to UL544 (File E151357),
CSA 22.2 No. 601.1 (File LR52335) and EN60-601/IEC601-1/DIN VDE 0750 (TÜV
Licenses R9271474, R9271475, R9271476).
8. Line regulation is measured under nominal load conditions
as the input voltage is varied from 85 to 265 VAC (ac-input
models) or from 36 to 75 VDC (dc-input models).
9. Load regulation is measured at 115 VAC or 230 VAC. For
single output models, load regulation is measured while out-
put current is varied from 0% to 100% of full load. With mul-
tiple output models, the output under test is brought to 60%
14. The DC2-40 and DC3-40 series are approved to UL1950 (File E140439), CSA22.2 No.
234 (File LR52335), and EN60950/IEC950/DIN VDE 0805 (TÜV License R9071501).
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
9
40W
OPEN-FRAME SWITCHING POWER SUPPLIES
FLU/MDU/DC 40W SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 ±0.01 inch.
0.000 ±0.005 inch.
C. P1 input connectors are Molex 26-62-4030. The mating con-
nector combines Molex housing 43061-0003 and crimp ter-
minal 08-70-1030.
D. P2 output connectors for the 40W series, except for models
5 and 6 of the FLU3-40 series, are Molex 26-60-4060. The
mating connector combines Molex housing 43061-0006 and
crimp terminal 08-70-1030. Models 5 and 6 of the FLU3-40
series use Molex 26-60-4080 for the P2 connector. The mat-
ing connector uses Molex housing 43061-0008 and crimp
terminals 08-70-1030.
Pin-Out
FLU2-40
FLU2-40
FLU3-40
FLU3-40
Pin
FLU1-40 MDU1-40 Models 1-4 Models 5-7 MDU2-40 DC2-40 Models 1-4 Models 5-6 MDU3-40 DC3-40
1
2
3
4
5
6
7
8
V1
V1
V1
Return
Return
Return
N/A
V1
V1
V1
Return
Return
Return
N/A
V2
V1
V1
+V1(ISO)
+V1(ISO)
- V1(ISO)
V2
V1
V1
V2
V1
V1
V2
V1
V1
+V2(ISO)
- V2(ISO)
+V1(ISO)
+V1(ISO)
- V1(ISO)
- V1(ISO)
+V3(ISO)
- V3(ISO)
V2
V1
V1
V2
V1
V1
Common
Common
N/C
- V1(ISO) Common Common Common
- V2(ISO) Common Common Common
+V2(ISO)
N/A
Common Common
Common Common
N/C
N/A
N/A
N/C
N/A
N/A
V3
N/A
N/A
V3
N/A
N/A
V3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
10
40W
POWER SUPPLY ENCLOSURES
L-Bracket
To order, change the part
number suffix from AD to BD
or from AC to BC.
1. Material is 0.036-inch cold-rolled
steel (20 AWG).
2. Finish is zinc and clear chromate
plating.
3. Dimensions are in inches.
4. Tolerances = 0.00 ±0.01
0.000 ±0.005
L-Bracket and Cover
To order full enclosure, change the part
number suffix from AD to CD or from AC
to CC.
1. Material is 0.036-inch cold-rolled steel (20 AWG).
2. Finish is zinc and clear chromate plating.
3. Dimensions are in inches.
4. Tolerances = 0.00 ±0.01
0.000 ±0.005
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
11
相关型号:
MDU200
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1012DG
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MDU200-1012G
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1012G
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MDU200-1024DG
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MDU200-1024G
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1048DG
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MDU200-1048G
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MDU200-1048G
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
©2020 ICPDF网 联系我们和版权申明