Features
A
K
■ Ultrafast recovery
■ Low power losses
K
■ High surge capability
■ Low leakage current
■ High junction temperature
A
A
NC
K
D2PAK
TO-220FPAC
STTH10R04G
STTH10R04FP
Description
K
K
The STTH10R04 is an ultrafast recovery power
rectifier dedicated to energy recovery in PDP
application.
A
NC
A
K
DPAK
STTH10R04B
TO-220AC
STTH10R04D
It is especially designed for clamping function in
energy recovery block.
The compromise between forward voltage drop
and recovery time offers optimized performances.
Table 1.
Device summary
IF(peak)
10 A
400 V
15 ns
VRRM
trr (typ)
Tj
175 °C
1.15 V
VF (typ)
November 2007
Rev 1
1/11
www.st.com
11
Characteristics
STTH10R04
1
Characteristics
Table 2.
Symbol
Absolute ratings (limiting values)
Parameter
Value
Unit
VRRM
Repetitive peak reverse voltage
400
20
V
A
IF(RMS) Forward current (rms)
Tc = 135 °C δ = 0.5
DPAK, TO-220AC, D2PAK
TO-220FPAC
Square signal
Peak working
IF(peak)
10
A
A
forward current
Tc = 130 °C δ = 0.5
Square signal
IFSM
Tstg
Tj
Surge non-repetitive forward current
Storage temperature range
tp = 10 ms sinusoidal
100
-65 to + 175
175
°C
°C
Maximum operating junction temperature
Table 3.
Symbol
Thermal parameters
Parameter
Value
Unit
DPAK, TO-220AC, D2PAK
TO-220FPAC
3.5
6
Rth(j-c)
Junction to case
°C/W
Table 4.
Symbol
Static electrical characteristics
Parameter
Test conditions
Min
Typ
Max
Unit
Tj = 25 °C
Tj = 125 °C
Tj = 25 °C
Tj = 125 °C
10
100
1.7
(1)
IR
Reverse leakage current
VR = VRRM
IF = 10 A
µA
10
1.5
(2)
VF
Forward voltage drop
V
1.15
1.35
1. Pulse test: tp = 5 ms, δ < 2%
2. Pulse test: tp = 380 µs, δ < 2%
To evaluate the conduction losses use the following equation:
2
P = 1.05 x I
+ 0.03 I
F(AV)
F (RMS)
Table 5.
Symbol
Recovery characteristics
Parameter
Test conditions
Min Typ Max Unit
IF = 0.5 A, Irr = 0.25 A, IR = 1 A
15
20
40
trr
Reverse recovery time
Forward recovery time
Tj = 25 °C
ns
IF = 1 A, VR = 30 V, dIF/dt = -50 A/µs
IF = 10 A, dIF/dt = 100 A/µs
VFR = 1.1 x VFmax
tfr
Tj = 25 °C
140 ns
VFP
IRM
Peak forward voltage
Tj = 25 °C IF = 10 A , dIF/dt = 100 A/µs
3
8
V
A
Reverse recovery current
6.2
0.3
IF = 10 A, VCC = 200 V
Tj = 125 °C
dIF/dt = 200 A/µs
Sfactor Softness factor
2/11
STTH10R04
Figure 1.
Characteristics
Conduction losses versus
average forward current
Figure 2.
Forward voltage drop versus
forward current
I
(A)
FM
P (W)
200
180
160
140
120
100
80
18
d=0.2
d=1
d=0.5
d=0.1
16
14
12
10
8
Tj=125°C
(Maximum values)
d=0.05
Tj=125°C
(Typical values)
Tj=25°C
(Maximum values)
6
60
T
4
40
2
20
I
(A)
V
(V)
F(av)
FM
0
0
0
2
4
6
8
10
12
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Figure 3.
Relative variation of thermal
Figure 4.
Relative variation of thermal
impedance junction to case versus
pulse duration
impedance junction to case versus
pulse duration
Zth(j-c)/Rth(j-c)
Zth(j-c)/Rth(j-c)
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Single pulse
D²PAK
DPAK
Single pulse
TO-220FPAC
tP(s)
tP(s)
1.E-03
1.E-02
1.E-01
1.E+00
1.E+01
1.E-04
1.E-03
1.E-02
1.E-01
1.E+00
Figure 5.
Peak reverse recovery current
Figure 6.
Reverse recovery time versus
versus dI /dt (typical values)
dI /dt (typical values)
F
F
t (ns)
rr
I
(A)
RM
80
70
60
50
40
30
20
10
0
14
13
12
11
10
9
8
7
6
5
IF=IF(AV)
VR=200V
Tj=125°C
IF=IF(AV)
VR=200V
Tj=125°C
4
3
2
1
dI /dt(A/µs)
F
dI /dt(A/µs)
F
0
0
50
100
150
200
250
300
350
400
450
500
0
50
100
150
200
250
300
350
400
450
500
3/11
Characteristics
STTH10R04
Figure 7.
Reverse recovery charges versus Figure 8.
dI /dt (typical values)
Reverse recovery softness factor
versus dI /dt (typical values)
F
F
QRR(nC)
S
factor
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
300
250
200
150
100
50
IF=IF(AV)
VR=200V
Tj=125°C
IF < 2 x IF(AV)
VR=200V
Tj=125°C
dI /dt(A/µs)
F
dI /dt(A/µs)
F
0
0
50
100
150
200
250
300
350
400
450
500
0
50
100
150
200
250
300
350
400
450
500
Figure 9.
Relative variations of dynamic
parameters versus junction
temperature
Figure 10. Transient peak forward voltage
versus dI /dt (typical values)
F
V
(V)
FP
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
25
12
11
10
9
IF=IF(AV)
VR=200V
Reference: Tj=125°C
IF=IF(AV)
Tj=125°C
SFACTOR
8
7
6
5
4
IRM
3
2
QRR
T (°C)
dI /dt(A/µs)
F
j
1
0
50
75
100
125
0
50
100
150
200
250
300
350
400
450
500
4/11
STTH10R04
Characteristics
Figure 11. Forward recovery time
Figure 12. Junction capacitance versus
versus dI /dt (typical values)
reverse voltage applied (typical
values)
F
C(pF)
t (ns)
fr
100
200
180
160
140
120
100
80
F=1MHz
OSC=30mVRMS
Tj=25°C
IF=IF(AV)
VFR=1.1 x VF max.
Tj=125°C
V
60
40
20
dI /dt(A/µs)
F
VR(V)
0
10
0
50
100
150
200
250
300
350
400
450
500
1
10
100
1000
Figure 13. Thermal resistance, junction to
ambient, versus copper surface
under tab (epoxy printed board
Figure 14. Thermal resistance, junction to
ambient, versus copper surface
under tab (epoxy printed board
FR4, copper thickness = 35 µm)
DPAK
FR4, copper thickness = 35 µm)
2
D PAK
Rth(j-a)(°C/W)
Rth(j-a)(°C/W)
100
90
80
70
60
50
40
30
20
10
0
80
70
60
50
40
30
20
10
0
DPAK
D²PAK
SCU(cm²)
20
SCU(cm²)
20
0
5
10
15
25
30
35
40
0
5
10
15
25
30
35
40
5/11
Package information
STTH10R04
2
Package information
●
●
●
●
Epoxy meets UL94, V0
Cooling method: by conduction (C)
Recommended torque calue: 0.8 N·m
Maximum torque value: 1.0 N·m
In order to meet environmental requirements, ST offers these devices in ECOPACK®
packages. These packages have a lead-free second level interconnect. The category of
second level interconnect is marked on the package and on the inner box label, in
compliance with JEDEC Standard JESD97. The maximum ratings related to soldering
conditions are also marked on the inner box label. ECOPACK is an ST trademark.
ECOPACK specifications are available at: www.st.com.
Table 6.
TO-220AC dimensions
Dimensions
Millimeters
Ref.
Inches
Min.
Max.
Min.
Max.
A
C
4.40
1.23
2.40
0.49
0.61
1.14
4.95
10.00
4.60
1.32
2.72
0.70
0.88
1.70
5.15
10.40
0.173
0.048
0.094
0.019
0.024
0.044
0.194
0.393
0.181
0.051
0.107
0.027
0.034
0.066
0.202
0.409
A
H2
Ø I
C
D
L5
L7
E
F
L6
F1
G
L2
D
F1
L9
H2
L2
L4
L5
L6
L7
L9
M
16.40 typ.
0.645 typ.
L4
13.00
2.65
14.00
2.95
0.511
0.104
0.600
0.244
0.137
0.551
0.116
0.620
0.259
0.154
F
M
E
15.25
6.20
15.75
6.60
G
3.50
3.93
2.6 typ.
0.102 typ.
Diam. I
3.75
3.85
0.147
0.151
6/11
STTH10R04
Package information
Dimensions
Table 7.
TO-220FPAC dimensions
Ref.
Millimeters
Inches
Min.
Max.
Min.
Max.
A
B
4.4
2.5
4.6
2.7
0.173
0.098
0.098
0.018
0.030
0.045
0.195
0.094
0.393
0.181
0.106
0.108
0.027
0.039
0.067
0.205
0.106
0.409
A
B
H
D
2.5
2.75
0.70
1
E
0.45
0.75
1.15
4.95
2.4
Dia
F
L6
L5
F1
G
1.70
5.20
2.7
L2
L3
L7
G1
H
10
10.4
D
F1
L2
L3
L4
L5
L6
L7
Dia.
16 Typ.
0.63 Typ.
L4
28.6
9.8
30.6
10.6
3.6
1.126
0.386
0.114
0.626
0.354
0.118
1.205
0.417
0.142
0.646
0.366
0.126
F
E
G1
2.9
G
15.9
9.00
3.00
16.4
9.30
3.20
7/11
Package information
Table 8.
STTH10R04
Inches
DPAK dimensions
Dimensions
Millimeters
Min. Max.
Ref.
Min.
Max.
A
A1
A2
B
2.20
0.90
0.03
0.64
5.20
0.45
0.48
6.00
6.40
4.40
9.35
2.40
1.10
0.23
0.90
5.40
0.60
0.60
6.20
6.60
4.60
10.10
0.086
0.035
0.001
0.025
0.204
0.017
0.018
0.236
0.251
0.173
0.368
0.094
0.043
0.009
0.035
0.212
0.023
0.023
0.244
0.259
0.181
0.397
E
A
B2
C2
L2
B2
C
D
R
H
L4
C2
D
A1
R
B
G
C
E
A2
G
0.60 MIN.
H
V2
L2
L4
V2
0.80 typ.
0.031 typ.
0.60
0°
1.00
8°
0.023
0°
0.039
8°
Figure 15. DPAK footprint (dimensions in mm)
1.6
6.7
3
3
2.3
6.7
2.3
1.6
8/11
STTH10R04
Package information
Dimensions
2
Table 9.
D PAK dimensions
Ref.
Millimeters
Inches
Min.
Max.
Min.
Max.
A
A1
A2
B
4.40
2.49
0.03
0.70
1.14
0.45
1.23
8.95
10.00
4.88
15.00
1.27
1.40
2.40
4.60
2.69
0.23
0.93
1.70
0.60
1.36
9.35
10.40
5.28
15.85
1.40
1.75
3.20
0.173
0.098
0.001
0.027
0.045
0.017
0.048
0.352
0.393
0.192
0.590
0.050
0.055
0.094
0.181
0.106
0.009
0.037
0.067
0.024
0.054
0.368
0.409
0.208
0.624
0.055
0.069
0.126
A
E
C2
L2
D
B2
C
L
L3
A1
C2
D
B2
B
R
C
E
G
G
A2
L
M
*
L2
L3
M
V2
* FLAT ZONE NO LESS THAN 2mm
R
0.40 typ.
0.016 typ.
V2
0°
8°
0°
8°
2
Figure 16. D PAK footprint (dimensions in mm)
16.90
10.30
5.08
1.30
3.70
8.90
9/11
Ordering information
STTH10R04
3
Ordering information
Table 10. Ordering information
Order code
Marking
Package
Weight
Base qty Delivery mode
STTH10R04FP
STTH10R04B
STTH10R04FP
STTH10R04B
STTH10R04B
STTH10R04G
STTH10R04G
STTH10R04D
TO-220FPAC
1.64 g
50
75
Tube
Tube
DPAK
0.3g
STTH10R04B-TR
STTH10R04G
2500
50
Tape and reel
Tube
D2PAK
1.48 g
1.86 g
STTH10R04G-TR
STTH10R04D
1000
50
Tape and reel
Tube
TO-220AC
4
Revision history
Table 11. Document revision history
Date
Revision
Description of changes
07-Nov-2007
1
First issue
10/11
STTH10R04
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the
right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any
time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no
liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this
document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products
or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS
OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT
RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING
APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY,
DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE
GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void
any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any
liability of ST.
ST and the ST logo are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2007 STMicroelectronics - All rights reserved
STMicroelectronics group of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan -
Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com
11/11
相关型号:
©2020 ICPDF网 联系我们和版权申明