FMP05-R60B [TDK]
AC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, PLASTIC PACKAGE;型号: | FMP05-R60B |
厂家: | TDK ELECTRONICS |
描述: | AC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, PLASTIC PACKAGE |
文件: | 总3页 (文件大小:106K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FMP, FMP-B Series
Power Supplies
AC Input
Single Output, General-Purpose
FEATURES
• Economical due to plastic case.
• FMP-B has pin terminals for board mounting.
• These low noise power supplies are FCC class B compliant.
PART NUMBERS AND RATINGS
3W type
Current(A)
10W type
Current(A)
Output voltage(V)
Part No.
Part No.
FMP05-R60
FMP05-R60B
FMP12-R25
FMP12-R25B
FMP15-R20
FMP15-R20B
FMP24-R13
FMP24-R13B
FMP05-2R0
FMP05-2R0B
FMP12-R85
FMP12-R85B
FMP15-R70
FMP15-R70B
FMP24-R45
FMP24-R45B
5
0.06 to 0.6
0.2 to 2
12
15
24
0.02 to 0.25
0.02 to 0.2
0.01 to 0.13
0.08 to 0.85
0.07 to 0.7
0.04 to 0.45
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. 1: DC output terminals(+, –)
Connect to load.
V.ADJ
+
–
1
DC OUTPUT
Terminal No. 2: No connection(NC)
Unconnected terminal. This should not be
connected.
POWER SUPPLY
FMP05-2R0
5V
2A
2
3
4
NC
Terminal No. 3: Ground terminal(
For input line.
)
100-120Vac
50-60Hz
0.35A
Terminal No. 4: AC input terminals(L, N, AC INPUT)
Connect to AC.100 to 120V single phase power
supply.
L
AC INPUT
N
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
FMP, FMP-B Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
3W TYPE
1
FMP05-R60
FMP05-R60B
5V • 0.6A
3
FMP12-R25
FMP15-R20
FMP15-R20B
15V • 0.2A
3
FMP24-R13
FMP24-R13B
24V • 0.13A
3.1
Part No.
1
FMP12-R25B
12V • 0.25A
3
2
Output voltage, current
Maximum output power
Input requirements
Input voltage Eac
Input frequency
W
V
Hz
A
A
mA
%
85 to 132[Rating: 100-120]
47 to 440[Single phase]
0.08typ.[85V, 25°C, input and output ratings](Output rating: 0.1max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
Input current
Surge current
Leakage current
Efficiency
68typ.
70typ.
70typ.
74typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
Overcurrent threshold
V
V
A
A
A
%
%
5
12
15
24
4.5 to 5.5
0.6
0.06
10.8 to 13.2
0.25
0.02
13.5 to 16.5
0.2
0.02
21.6 to 26.4
0.13
0.01
2
3
0.7 to 1.2
0.3 to 0.5
0.25 to 0.4
0.15 to 0.3
Input variation
Load variation
Temperature
variation
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage
stability
%
1typ.[0 to +50°C]
Drift
Dynamic load
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
mV
ms
Ripple Ep-p
50max.
100max.
100max.
20min.
80max.
150max.
80max.
150max.
100max.
150max.
Ripple noise Ep-p
Start up time
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
None
4
Uses overvoltage prevention
Fixed voltage threshold type, automatic recovery.
None
None
None
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Construction
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
External dimensions H×W×L
Weight
mm
g
19×55×50[Except input and output terminals]
80max.
Mounting method
Case material
Input and output cables
Can be attached to 1 side.
Nonflammable resin
None
1 Output may fail to come on when operated in series.
2 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
3
The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might pos-
sibly not be satisfied when output is below the minimum output current.
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
4
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
FMP, FMP-B Series
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
10W TYPE
1
FMP05-2R0
FMP05-2R0B
5V • 2A
10
FMP12-R85
FMP15-R70
FMP15-R70B
15V • 0.7A
10.5
FMP24-R45
FMP24-R45B
24V • 0.45A
10.8
Part No.
1
FMP12-R85B
12V • 0.85A
10.2
2
Output voltage, current
Maximum output power
Input requirements
Input voltage Eac
Input frequency
W
V
Hz
A
A
mA
%
85 to 132[Rating: 100-120]
47 to 440[Single phase]
0.25typ.[85V, 25°C, input and output ratings](Output ratings: 0.35max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
Input current
Surge current
Leakage current
Efficiency
75typ.
78typ.
78typ.
81typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
Overcurrent threshold
V
V
A
A
A
%
%
5
12
15
24
4.5 to 5.5
2
0.2
10.8 to 13.2
0.85
0.08
13.5 to 16.5
0.7
0.07
21.6 to 26.4
0.45
0.04
2
3
2.2 to 3.3
0.9 to 1.4
0.75 to 1.2
0.5 to 0.8
Input variation
Load variation
Temperature
variation
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage
stability
%
1typ.[0 to +50°C]
Drift
Dynamic load
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
%/ms
mV
mV
ms
Ripple Ep-p
50max.
100max.
100max.
20min.
80max.
150max.
80max.
150max.
100max.
150max.
Ripple noise Ep-p
Start up time
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
None
4
Uses overvoltage prevention
Fixed voltage threshold type, automatic recovery.
None
None
None
Output voltage external function
Standards
Safety standards
Noise terminal voltage
Construction
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
External dimensions H×W×L
Weight
mm
g
19×55×80[Except input and output terminals]
100max.
Mounting method
Case material
Input and output cables
Can be attached to 1 side.
Nonflammable resin
None
1 Output may fail to come on when operated in series.
2 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
3
The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values
might possibly not be satisfied when output is below the minimum output current.
Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
4
A122_FMP
980403
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
相关型号: