TFS111B
型号: TFS111B
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器
文件: 总5页 (文件大小:156K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
file: tfs111b.doc  
26.02.2002  
version 2.0  
VI TELEFILTER  
Filter specification  
TFS 111B  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances *)  
for input:  
23°C  
0dBm  
3,2 k||- 5,6pF  
3,1 k|| -6.2pF  
for output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a of TFS 111B is the minimum of the pass band attenuation a  
. This value is defined as the  
min  
rel  
insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 20,0 dB filter attenuation level  
e
c
relative to the insertion loss a  
e.  
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
a
= a  
e min  
7
111  
1
dB  
11  
± 60  
2
dB  
(reference level)  
Centre frequency  
f
(30 dB-BW)  
kHz  
c
MHz  
dB  
kHz  
dB  
Relative attenuation  
a
rel  
f
-
500  
kHz ... f + 500  
max.  
c
c
f
c
f
c
f
c
±
±
±
1
2
3
MHz ... f  
MHz ... f  
MHz ... f  
±
±
±
2
3
MHz  
MHz  
MHz  
22  
33  
45  
dB  
dB  
dB  
min. 20  
min. 30  
min. 40  
dB  
dB  
dB  
c
c
c
10  
**)  
Group delay  
Ripple ± 500 kHz  
GD  
f
300  
ns  
max 500  
-
ns  
c
Temperature coefficient  
TC 2nd order **)  
- 0,032 ppm/K²  
Frequency inversion temperature To  
25  
°C  
Operating temperature range  
Storage temperature range  
- 10 °C ... + 60 °C  
- 40 °C ... + 85 °C  
Input power level  
-
max. + 10  
dBm  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.  
**) - f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz)  
Generated:  
Checked / approved:  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
file: tfs111b.doc  
26.02.2002  
version 2.0  
VI TELEFILTER  
Filter specification  
TFS 111B  
2/5  
Construction and pin connection  
(All dimensions in mm)  
1
Ground  
2
Ground  
S 111 B  
P09  
3
Output RF Return  
Output  
4
5
Ground  
6
Ground  
1
3
7
Ground  
8
Ground  
9
Input RF Return  
Input  
10  
11  
12  
Ground  
7,2 Max.  
2,54+-0,2  
Ground  
Datecode:  
Year+week  
2000  
M
N
P
2001  
2002  
...  
0,8  
50 test circuit  
L1  
10  
L2  
4
Input  
50 Ohm  
Input  
50 Ohm  
SAW  
C1  
C2  
1,2,3,5,6,7,  
8,9,11,12  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
file: tfs111b.doc  
26.02.2002  
version 2.0  
VI TELEFILTER  
Filter specification  
TFS 111B  
3/5  
Stability Characteristics:  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
temperature:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
-55 °C to 125°C / 30 min each. / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing:  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
Reel of empty components at start:  
Reel of empty components at start including leader:  
Trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
:
:
16  
4
± 0,3  
± 0,1  
2
Po  
P
D
o
Do  
E
F
G (min) :  
P2  
:
1,5 + 0,1  
E
F
:
:
1,75 ± 0,1  
7,5 ± 0,1  
0,6  
o
A
1
D
W
o
B
Ct  
:
2
± 0,1  
P1  
:
8
± 0,1  
G
D1(min) : 1,5  
Ao  
Bo  
Ct  
:
:
:
5,5 ± 0,1  
7,5 ± 0,1  
13,5+/-0,1  
P1  
COVER TAPE  
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
16,4 +2  
22,4  
W2 (max) :  
N (min)  
C
:
:
50  
C
A
13 + 0,5  
- 0,2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
file: tfs111b.doc  
26.02.2002  
version 2.0  
VI TELEFILTER  
Filter specification  
TFS 111B  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature:  
Time:  
150 °C - 170 °C  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
temperature / °C  
23  
34  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
150  
20  
46  
160  
30  
60  
170  
40  
80  
180  
50  
103  
121  
134  
143  
150  
154  
156  
158  
159  
190  
60  
195  
70  
200  
80  
205  
90  
210  
100  
110  
120  
130  
215  
220  
230  
240  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
file: tfs111b.doc  
26.02.2002  
version 2.0  
VI TELEFILTER  
History  
Filter specification  
TFS 111B  
5/5  
Version  
Reason of Changes  
Name  
Date  
Development specification  
1.1.  
- passband ripple: 3dB Î 1.5 dB  
Steiner  
Steiner  
08.05.2000  
28.07.2000  
- new datecode introduced and explained  
1.2.  
- complete specification  
- passband ripple, group delay ripple, attenuation at fc+-1MHz  
changed according to agreements with customer  
Filter specification  
2.0  
- typical values and terminating impedance added  
Steiner  
26.02.2002  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS112H

Filter Specification
VECTRON

TFS112K

Filter Specification
VECTRON

TFS112R

Filter specification
VECTRON

TFS1150A

Development specification
VECTRON

TFS115A

Filter specification
VECTRON

TFS115C

Filter specification
VECTRON

TFS115D

Filter specification
VECTRON

TFS115E

Filter specification
VECTRON

TFS116

Filter Specification
VECTRON

TFS117

Filter specification
VECTRON

TFS1176

Filter specification
VECTRON

TFS117A

Filter Specification
VECTRON