TFS119A [VECTRON]

SAW Filter Specification; SAW滤波器规格
TFS119A
型号: TFS119A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

SAW Filter Specification
SAW滤波器规格

LTE
文件: 总5页 (文件大小:48K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Tfs119a.doc  
version 1.6  
14.09.2000  
______________________________________________________________________________________________________  
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________  
TFS 119A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances  
for input:  
23 °C  
0
dBm  
750 Ohm // -3.9 pF  
750 Ohm // -3.9 pF  
279 nH  
for output:  
External coil:  
Characteristics  
Remark:  
Reference level for the relative attenuation a of the TFS 119A is the insertion loss. The insertion loss a is defined as the insertion loss at the  
rel  
C
e
nominal frequency f . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level  
N
relative to the insertion loss a . The nominal frequency f is fixed on 119.6 MHz without tolerance. The specified values have to be reached in  
e
N
operating temperature range.  
D a t a  
typ. Value  
tolerance/limit  
1.25...3.25 dB  
Insertion loss  
a
f
e
1.85  
dB  
(Reference level)  
Nominal frequency  
Centre frequency  
-
119,600 MHz  
N
f
119,605 MHz  
-
-
C
1 dB bandwidth  
BW  
162  
MHz  
Relative attenuation  
a
rel  
f
N ± 0,8 MHz ... fN ± 1,8 MHz  
45  
43...48  
27...89  
dB  
dB  
dB  
min. 20  
min. 30  
min. 10  
dB  
dB  
dB  
fN ± 1,8 MHz ... fN ± 6 MHz  
fN ± 6 MHz ... fN ± 100 MHz  
VSWR  
@ fN  
1,5 : 1  
max.  
1,8 : 1  
Group delay  
GD  
@ fN  
4,2  
-
µs  
max.  
8,2  
µs  
Input power  
max. 13  
dBm  
Operating temperature range  
- 5 °C ... + 80 °C  
Temperature coefficient of frequency TC  
Frequency inversion temperature  
ca. – 0,036 ppm/K²  
+ 35 °C  
Generated:  
Checked / approved:  
VI TELEFILTER  
Vectron International, Inc.  
Potsdamer Straße 18  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs119a.doc  
version 1.6  
14.09.2000  
______________________________________________________________________________________________________  
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________  
TFS 119A  
2/5  
Construction, pin configuration and 50 - matching network  
(All dimensions in mm)  
Datecode:  
K
L
Year+week  
1998  
1999  
TFS 119 A  
M37  
M
...  
2000  
DateCode  
Pin 1, 2, 3, 6, 7, 8, 10:  
Ground  
Output  
External Coil  
Input  
Pin 4:  
Pin 5:  
Pin 9:  
50 Ohm Test circuit 1  
L1  
L2  
50 Ohm  
50 Ohm  
9
4
C1  
C2  
SAW  
5
L3  
1,2,3,6,7,8,10  
50 Ohm Test circuit 2  
C1  
C2  
50 Ohm  
50 Ohm  
9
4
L1  
L2  
SAW  
5
L3  
1,2,3,6,7,8,10  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs119a.doc  
version 1.6  
14.09.2000  
______________________________________________________________________________________________________  
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________  
TFS 119A  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Damp heat:  
(cycle)  
25 °C to 55°C / 95% r.H. / 10 cycles  
DIN IEC 68 - 2 – 30 Db  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
Real of empty components at start:  
Real of empty components at start including leader:  
Trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
:
:
:
24  
4
± 0,3  
± 0,1  
Po  
Do  
Po  
P 2  
D
o
1,5 + 0,1  
E
F
E
F
:
:
1,75 ± 0,1  
7,5 ± 0,1  
0,6  
Ao  
D1  
G (min) :  
CT  
W
Bo  
P2  
P1  
:
2
8
± 0,1  
± 0,1  
:
G
D1(min) : 1,5  
Ao  
Bo  
CT  
:
:
5,6 ± 0,1  
11,8 ± 0,1  
21,5 ± 0,1  
P1  
COVER TAPE  
:
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
:
24,4 +2  
W2 (max) :  
30,4  
60  
N (min)  
C
C
A
:
13 +0,5/-0,2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs119a.doc  
version 1.6  
14.09.2000  
______________________________________________________________________________________________________  
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________  
TFS 119A  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs119a.doc  
version 1.6  
14.09.2000  
______________________________________________________________________________________________________  
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________  
TFS 119A  
5/5  
History  
Version  
Reason of Changes  
Name  
Date  
1.2  
Add preliminary values for termination impedance  
Add history  
Dr. Wall  
09.05.2000  
Modify monthly date code into weekly date code  
Corrected tape and reel information  
1.3  
1.4  
Add final termination conditions  
Add typical filter data  
Add limits for insertion loss  
Dr. Wall  
Dr. Wall  
16.06.2000  
28.06.2000  
Add maximum input power  
Add reletive attenuation value for FN ± 6 MHz ... FN ± 100 MHz  
Add group delay  
Notice 1 dB bandwidth instead of 3 dB bandwidth  
Increase window for insertion loss to two dB  
1.5  
1.6  
Change filter name to TFS119A  
Add external coil  
Change input power level to 13 dBm  
Remove typical filter values  
Remove termination impedances  
Dr. Wall  
Dr. Wall  
19.07.2000  
14.09.2000  
Add termination impedances and coupling coil value  
Define insertion loss window  
Add typical values for filter data  
Add maximum value for group delay  
Correct filter marking  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS119B

Filter specification
VECTRON

TFS120

Filter Specification
VECTRON

TFS1200

Filter specification
VECTRON

TFS120A

Filter specification
VECTRON

TFS120C

Filter specification
VECTRON

TFS120E

Filter specification
VECTRON

TFS121

Filter Specification
VECTRON

TFS121B

Filter specification
VECTRON

TFS1220

Filter specification
VECTRON

TFS1220B

VI TELEFILTER
VECTRON

TFS1220_03

The filter is single ended driven
VECTRON

TFS1237

Filter specification
VECTRON