TFS119A [VECTRON]
SAW Filter Specification; SAW滤波器规格型号: | TFS119A |
厂家: | Vectron International, Inc |
描述: | SAW Filter Specification |
文件: | 总5页 (文件大小:48K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Tfs119a.doc
version 1.6
14.09.2000
______________________________________________________________________________________________________
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________
TFS 119A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
23 °C
0
dBm
750 Ohm // -3.9 pF
750 Ohm // -3.9 pF
279 nH
for output:
External coil:
Characteristics
Remark:
Reference level for the relative attenuation a of the TFS 119A is the insertion loss. The insertion loss a is defined as the insertion loss at the
rel
C
e
nominal frequency f . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
N
relative to the insertion loss a . The nominal frequency f is fixed on 119.6 MHz without tolerance. The specified values have to be reached in
e
N
operating temperature range.
D a t a
typ. Value
tolerance/limit
1.25...3.25 dB
Insertion loss
a
f
e
1.85
dB
(Reference level)
Nominal frequency
Centre frequency
-
119,600 MHz
N
f
119,605 MHz
-
-
C
1 dB bandwidth
BW
162
MHz
Relative attenuation
a
rel
f
N ± 0,8 MHz ... fN ± 1,8 MHz
45
43...48
27...89
dB
dB
dB
min. 20
min. 30
min. 10
dB
dB
dB
fN ± 1,8 MHz ... fN ± 6 MHz
fN ± 6 MHz ... fN ± 100 MHz
VSWR
@ fN
1,5 : 1
max.
1,8 : 1
Group delay
GD
@ fN
4,2
-
µs
max.
8,2
µs
Input power
max. 13
dBm
Operating temperature range
- 5 °C ... + 80 °C
Temperature coefficient of frequency TC
Frequency inversion temperature
ca. – 0,036 ppm/K²
+ 35 °C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs119a.doc
version 1.6
14.09.2000
______________________________________________________________________________________________________
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________
TFS 119A
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
Datecode:
K
L
Year+week
1998
1999
TFS 119 A
M37
M
...
2000
DateCode
Pin 1, 2, 3, 6, 7, 8, 10:
Ground
Output
External Coil
Input
Pin 4:
Pin 5:
Pin 9:
50 Ohm Test circuit 1
L1
L2
50 Ohm
50 Ohm
9
4
C1
C2
SAW
5
L3
1,2,3,6,7,8,10
50 Ohm Test circuit 2
C1
C2
50 Ohm
50 Ohm
9
4
L1
L2
SAW
5
L3
1,2,3,6,7,8,10
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs119a.doc
version 1.6
14.09.2000
______________________________________________________________________________________________________
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________
TFS 119A
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
:
:
:
24
4
± 0,3
± 0,1
Po
Do
Po
P 2
D
o
1,5 + 0,1
E
F
E
F
:
:
1,75 ± 0,1
7,5 ± 0,1
0,6
Ao
D1
G (min) :
CT
W
Bo
P2
P1
:
2
8
± 0,1
± 0,1
:
G
D1(min) : 1,5
Ao
Bo
CT
:
:
5,6 ± 0,1
11,8 ± 0,1
21,5 ± 0,1
P1
COVER TAPE
:
W
2
Reel (all dimensions in mm):
A
:
330
W1
:
:
24,4 +2
W2 (max) :
30,4
60
N (min)
C
C
A
:
13 +0,5/-0,2
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs119a.doc
version 1.6
14.09.2000
______________________________________________________________________________________________________
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________
TFS 119A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: pre-heating periods
main-heating periods
over 200 °C
peak temperature
255 °C ± 5 °C
Temperature: 150 °C - 170 °C
Time:
60 sec. - 90 sec.
20 sec. - 25 sec.
Chip-mount air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
10
20
30
40
50
60
70
80
90
100
110
120
130
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs119a.doc
version 1.6
14.09.2000
______________________________________________________________________________________________________
V__I__T_E__L__E_F__IL__T_E__R____________________S__A__W___F_i_l_te__r_S__p__e_c_i_f_i_c_a_t_i_o_n______________________________________
TFS 119A
5/5
History
Version
Reason of Changes
Name
Date
1.2
Add preliminary values for termination impedance
Add history
Dr. Wall
09.05.2000
Modify monthly date code into weekly date code
Corrected tape and reel information
1.3
1.4
Add final termination conditions
Add typical filter data
Add limits for insertion loss
Dr. Wall
Dr. Wall
16.06.2000
28.06.2000
Add maximum input power
Add reletive attenuation value for FN ± 6 MHz ... FN ± 100 MHz
Add group delay
Notice 1 dB bandwidth instead of 3 dB bandwidth
Increase window for insertion loss to two dB
1.5
1.6
Change filter name to TFS119A
Add external coil
Change input power level to 13 dBm
Remove typical filter values
Remove termination impedances
Dr. Wall
Dr. Wall
19.07.2000
14.09.2000
Add termination impedances and coupling coil value
Define insertion loss window
Add typical values for filter data
Add maximum value for group delay
Correct filter marking
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明