TFS171A [VECTRON]

Filter Specification; 过滤器规格
TFS171A
型号: TFS171A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器
文件: 总5页 (文件大小:236K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
File name: Tfs171A.doc  
version 1.4  
26.04.2002  
VI TELEFILTER  
Filter Specification  
TFS 171A  
1/5  
1. Measurement condition :  
Ambient temperature TA:  
Input power level:  
23  
0
°C  
dBm  
Terminating impedances in f *) :  
for input:  
960  -8,3. pF.  
1,17 K -7,5. pF.  
c
for output:  
2.  
Characteristics :  
Remark: Reference level for the relative attenuation a  
rel  
of the TFS 171A is the minimum of the pass band attenuation a  
. The minimum of  
min  
the pass band attenuation a  
is defined as the insertion loss a . The nominal frequency fN is fixed to 171,20 MHz. The centre frequency f is  
min  
e
c
the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss a . All specified  
e
parameters have to be reached in the operating temperature range.  
Data  
typ. value  
tolerance / limit  
Insertion loss at ambient temperature :  
5,5  
dB  
9,5  
dB  
MHz  
Nominal frequency  
fN  
-
171,2  
Centre frequency at ambient temperature  
Bandwidth  
fc  
171,22  
MHz  
171,2 ± 0,1 MHz  
1
3
dB - band width  
dB - band width  
870  
1350  
2680  
kHz  
kHz  
KHz  
min. 400  
min. 900  
max. 3300  
kHz  
kHz  
kHz  
20 dB - band width  
Relative attenuation  
a
rel  
fN ± 0,2 MHz  
fN  
....  
-
-
max.  
max.  
1
3
dB  
dB  
fN ± 0,2 MHz .... fN ± 0,45 MHz  
fN ± 1,65 MHz .... fN ±  
5
MHz  
MHz  
MHz  
33  
46  
55  
dB  
dB  
dB  
min. 20  
min. 35  
min. 45  
dB  
dB  
dB  
fN ±  
5
MHz .... fN ± 40  
MHz .... fN ±100  
fN ± 40  
Group delay ( mean value)  
Group delay ripple in  
Phase ripple in  
fN ± 200 kHz  
fN ± 200 kHz (p-p)  
fN ± 200 kHz (p-p)  
740  
50  
ns  
ns  
max.  
max. 400  
1
µs  
ns  
4 °  
Input power level  
-
max. 10  
dBm  
Frequency inversion temperature ( To ) :  
Temperature coefficient of frequency ( Tcf ) :  
20..25 °C  
- 0,036 ppm/K²  
f (Hz) = Tcf(ppm/K) x (T - To)² x fO (MHz)  
Frequency deviation of f over temperature: ** )  
c
c
Operating temperature range ( OTR ) :  
- 40 °C ... + 85 °C  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
Generated:  
Checked/Approved:  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs171A.doc  
version 1.4  
26.04.2002  
VI TELEFILTER  
Filter Specification  
TFS 171A  
2/5  
3. Construction and pin connection : (All dimensions in mm)  
S 171 A  
P17  
Date code  
Datecode:  
Year+week  
2000  
M
N
P
2001  
2002  
...  
Pin 9  
Input.  
Pin 10 Input RF Return.  
Pin 3  
Output.  
Pin 4  
Output RF Return.  
Pin 1, 2, 5 - 8, 11, 12 - Package Ground.  
4. 50 matching network  
L21  
L22  
50  
1
2
L4  
4
12  
11  
5
6
10  
L3  
9
8
7
50  
L11  
L12  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs171A.doc  
version 1.4  
26.04.2002  
VI TELEFILTER  
Filter Specification  
TFS 171A  
3/5  
5. Stability characteristics :  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
older heat (reflow):  
reflow possible: twice max.;for temperature conditions, please refer to the attached "Air  
reflow temperature conditions" on page 4  
6. Packing :  
Tape & Reel:  
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
Trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
P o  
P
2
D
o
W
Po  
Do  
E
:
:
:
:
:
16± 0,3  
E
4
± 0,1  
A
o
1,5 + 0,1  
1,75 ± 0,1  
7,5 ± 0,1  
F
D
1
F
CT  
W
B
o
G (min) : 0,6  
P2  
P1  
:
:
2
8
± 0,1  
± 0,1  
G
D1(min): 1,5  
Ao  
Bo  
Ct  
:
:
:
5,5 ± 0,2  
7,5 ± 0,2  
13,5 ± 0,1  
P 1  
COVER TAPE  
W2  
Reel (all dimensions in mm):  
A
:
:
330  
W1  
16,4 + 2  
22,4  
50  
N
C
W2(max) :  
A
N(min)  
C
:
:
13,00 +0,50 / -0,20  
W1  
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs171A.doc  
version 1.4  
26.04.2002  
VI TELEFILTER  
Filter Specification  
TFS 171A  
4/5  
7. Air reflow temperature conditions :  
1st and 2nd air reflow profile  
Name:  
pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
Temperature: 150 °C - 170 °C  
255 °C ± 5 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
temperature / °C  
23  
34  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
150  
20  
46  
160  
30  
60  
170  
40  
80  
180  
50  
103  
121  
134  
143  
150  
154  
156  
158  
159  
190  
60  
195  
70  
200  
80  
205  
90  
210  
100  
110  
120  
130  
215  
220  
230  
240  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs171A.doc  
version 1.4  
26.04.2002  
VI TELEFILTER  
Filter Specification  
TFS 171A  
5/5  
8. History :  
Version  
1.0  
Reason of Changes  
Name  
Date  
Generation of preliminary specification according to customer requirements.  
Change package according to customer requirements.  
Dunzow W.  
Dunzow W.  
Dunzow W.  
Dunzow W.  
18.09.2001  
30.10.2001  
08.11.2001  
11.12.2001  
1.1  
1.2  
Change pin connection according to customer requirements.  
1.3  
Correct error in unbalanced scheme 1.  
Remove balanced scheme 2.  
1.4  
Add of typical values and change to filter specification  
Dr. Sabah  
26.04.2002  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS172A

Filter specification
VECTRON

TFS172B

Filter specification
VECTRON

TFS173A

Filter Specification
VECTRON

TFS174

Filter Specification
VECTRON

TFS1747

VI TELEFILTER
VECTRON

TFS1747_07

VI TELEFILTER
VECTRON

TFS174C

Filter Specification
VECTRON

TFS174D

Filter Specification
VECTRON

TFS175A

Filter Specification
VECTRON

TFS175D

Filter specification
VECTRON

TFS175K

SAW Filter, 1 Function(s), 175MHz,
MICROSEMI

TFS179

Filter Specification
VECTRON