Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance:  
Input:  
23  
0
°C  
dBm  
43 || - 1 pF  
43 || - 1 pF  
Output:  
Source Impedance:  
Load Impedance:  
50  
50  
Characteristics  
Remark:  
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 1747,5 MHz without any tolerance or  
e
limit. The values of absolute attenuation a  
temperature range is included in the production tolerance scheme.  
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating  
abs  
D a t a  
typ. value  
tolerance / limit  
a
2
dB  
max.  
2,5  
dB  
Insertion loss  
e
fN  
-
-
1747,5  
MHz  
Nominal frequency  
Passband  
PB  
fN  
±
37,5 MHz  
a
Absolute attenuation  
abs  
1
350  
1819  
MHz ...  
MHz ...  
MHz ...  
350 MHz  
1678 MHz  
4000 MHz  
48  
15  
18  
dB  
dB  
dB  
min.  
min.  
min.  
34  
14  
14  
dB  
dB  
dB  
-
max.  
max.  
17  
8
dBm  
dB  
Input power level wilthin PB  
Return loss within PB  
10,5  
dB  
- 40 °C ... + 85°C  
OTR  
-
-
Operating temperature range  
Storage temperature range  
- 40 °C ... + 85°C  
-
TC  
f
*
-46  
ppm/K  
Temperature coefficient of frequency  
*) f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).  
f
To  
Generated:  
Checked / Approved:  
Filter characteristic  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 1747.doc  
Version 1.5  
26.06.2007  
VI TELEFILTER  
Filter specification  
TFS 1747  
2/5  
0
-1  
5
0
-5  
4.5  
4
-2  
-10  
-15  
-20  
-25  
-30  
-35  
-40  
-45  
-50  
-3  
3.5  
3
-4  
-5  
2.5  
2
-6  
-7  
1.5  
1
-8  
-9  
0.5  
-10  
0
16  
88  
1700  
1712  
1724  
1736  
1748  
1760  
1772  
1784  
1796  
180088  
10  
410  
810 1210 1610 2010 2410 2810 3210 3610 4010  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
1
2
3
4
5
6
Ground  
Input  
Ground  
Ground  
Output  
Ground  
K47  
V26  
Date code: Year + week  
V
W
X
2007  
2008  
2009  
...  
50 Test circuit  
2
5
C1  
L1  
C2  
L2  
1, 3, 4, 6  
Stability characteristics, reliability  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 1747.doc  
Version 1.5  
26.06.2007  
VI TELEFILTER  
Filter specification  
TFS 1747  
3/5  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: three times max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
9000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3  
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
3,50 ± 0,05  
0,75  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
2,00 ± 0,05  
4,00 ± 0,1  
1,50  
3,25 ± 0,1  
3,25 ± 0,1  
5,5 ± 0,1  
Ko  
Typ  
PIN Marker  
D1  
Ao  
Ct  
W
2
Reel (all dimensions in mm)  
A
W1  
:330  
: 8,4 +1,5/-0  
W2(max) : 14,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 1747.doc  
Version 1.5  
26.06.2007  
VI TELEFILTER  
Filter specification  
TFS 1747  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 1747.doc  
Version 1.5  
26.06.2007  
VI TELEFILTER  
Filter specification  
TFS 1747  
5/5  
History  
Version  
1.0  
Reason of Changes  
Name  
Date  
- generation of specification according to customer requirements.  
- Add of matching network  
Roizengaft  
Roizengaft  
Dr. Wall  
16.02.2004  
25.02.2004  
13.05.2004  
26.07.2004  
1.1  
1.2  
- Change absolute attenuation from 11 dB to 14 dB  
- Change test circuit  
1.3  
M.Springfeldt  
1.4  
- Changed reflow profile; added typical values and filter characteristic;  
generation of filter specification  
Martens  
Strehl  
18.01.2005  
26.06.2007  
1.5  
- Changed OTR and stability characteristics  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS1747_07

VI TELEFILTER
VECTRON

TFS174C

Filter Specification
VECTRON

TFS174D

Filter Specification
VECTRON

TFS175A

Filter Specification
VECTRON

TFS175D

Filter specification
VECTRON

TFS175K

SAW Filter, 1 Function(s), 175MHz,
MICROSEMI

TFS179

Filter Specification
VECTRON

TFS182

Filter specification
VECTRON

TFS183A

Development specification
VECTRON

TFS183B

Development specification
ETC

TFS1842

Preliminary Specification
VECTRON

TFS1842A

Development specification
VECTRON