MDP-DM/A33 [MSYSTEM]

Lightning Surge Protectors for Electronics Equipment M-RESTER;
MDP-DM/A33
型号: MDP-DM/A33
厂家: M-SYSTEM    M-SYSTEM
描述:

Lightning Surge Protectors for Electronics Equipment M-RESTER

文件: 总4页 (文件大小:119K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: MDP-DM  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M4 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel  
Housing material: Flame-resistant resin (black)  
LIGHTNING SURGE PROTECTOR FOR  
DATA-M USE  
Functions & Features  
INSTALLATION  
• Protects from lightning surges entering through twisted-  
pair cables connecting DATA-M systems  
• Absorbs surges only without affecting instrumentation  
signal  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 100 g (0.22 lb), standard; 125 g (0.28 lb), with DIN  
rail mounting adapter  
• No interruption of signal by unplugging the protector  
element  
PERFORMANCE  
Max. continuous operating voltage (Uc):  
23.5 (.93)  
Line to line: ±140 V  
Line to earth: ±500 V  
Voltage protection level (Up):  
• @ 1 kV (100 A)  
Lot.NO  
N1430B  
100  
(3.94)  
JPAN  
MADEIN  
Line to line: ±650 V  
M•STER  
MODEL  
Line to earth: ±650 V  
• @ 2 kV (1 kA)  
80 (3.15)  
mm (inch)  
Line to line: ±800 V  
Line to earth: ±800 V  
Response time: ≤ 1 μsec.  
Leakage current:  
MODEL: MDP–DM[1]  
Line to line: ≤ 50 μA @ ±140 V DC  
Line to earth: ≤ 50 μA @ ±140 V DC  
Max. discharge current (Imax): 5000 A (8 / 20 μs)  
ORDERING INFORMATION  
• Code number: MDP-DM[1]  
Specify a code from below for [1].  
(e.g. MDP-DM/A33/Q)  
Nominal current (I ): 100 mA  
N
Internal series resistance: ≤ 0.1 Ω  
Capacitance @ 1 MHz:  
• Specify the specification for option code /Q  
(e.g. /C01)  
Line to line: ≤ 100 pF  
Line to earth: ≤ 100 pF  
Surge protection: IEC 61643-21 Categories C1, C2  
[1] OPTIONS (multiple selections)  
DIN Rail Mounting Adapter  
blank: Without  
/A33: With adapter (model A-33)  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
MDP-DM SPECIFICATIONS  
ES-8120 Rev.2 Page 1/4  
http://www.m-system.co.jp/  
MODEL: MDP-DM  
CONNECTION EXAMPLES  
1 meter max. (3.28 ft)  
DATA−M  
MDP−DM  
+
P1  
P2  
S1  
S2  
1 meter max. (3.28 ft)  
G
G
MDP−DM  
DATA−M  
(PROTECTED EQUIPMENT)  
+
S1  
S2  
P1  
P2  
1 meter max. (3.28 ft)  
G
G
DATA−M  
MDP−DM  
+
P1  
P2  
S1  
S2  
(Protected device)  
G
G
(PROTECTED EQUIPMENT)  
Max. two sets of twisted-pair cables are connectable to one MDP-DM.  
GROUNDING  
PROTECTED  
EQUIPMENT  
M-RESTER  
G
G
GROUNDING  
(100 ohms or less)  
CROSSOVER WIRE  
A crossover wire between M-RESTER ground and the ground or  
metallic housing of the equipment is required for protection.  
If the protected equipment has no ground terminal, ground the  
M-RESTER only.  
When the M-RESTER is mounted with DIN Rail Mounting Adapter,  
connect the grounding wire to the mounting screw of the M-RESTER.  
MDP-DM SPECIFICATIONS  
ES-8120 Rev.2 Page 2/4  
http://www.m-system.co.jp/  
MODEL: MDP-DM  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
STANDARD  
80 (3.15)  
53 (2.09)  
2–5 (.20) dia.  
MTG HOLE  
23.5 (.93)  
27 (1.06)  
HEAD ELEMENT  
P1  
P2  
BASE  
4–M4 TERMINAL SCREW  
S1  
S2  
GROUND TERMINAL (G)  
(used as mounting bracket)  
WITH DIN RAIL MOUNTING ADAPTER  
8.5  
(.33)  
[3.3 (.13)]  
80 (3.15)  
53 (2.09)  
27 (1.06)  
23.5 (.93)  
DIN RAIL  
35mm wide  
P1 P2  
4–M4 TERMINAL SCREW  
S1 S2  
2–M4 MOUNTING SCREW  
(used as ground terminal (G))  
MOUNTING REQUIREMENTS unit: mm (inch)  
2–M4 SCREW  
25 (.97) min.  
MDP-DM SPECIFICATIONS  
ES-8120 Rev.2 Page 3/4  
http://www.m-system.co.jp/  
MODEL: MDP-DM  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
S1  
P1  
ELEMENT  
TO CABLE  
TO EQUIPMENT  
Discharge Elements  
S2  
P2  
BASE  
G
GROUND TERMINAL  
(used as mounting attachment)  
Specifications are subject to change without notice.  
MDP-DM SPECIFICATIONS  
ES-8120 Rev.2 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

MDP-DM/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-DM3

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-DM3/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-DM3/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-EC

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-EC/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-EC/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-FT

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-FT/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-FT/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-JS

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-JS/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM