CAN and LIN Interfaces for Hi-Speed USB
NI USB-8472, NI USB-8472s, NI USB-8473,
NI USB-8473s, NI USB-8476, NI USB-8476s,
• 1-port interfaces for high-speed CAN,
low-speed/fault-tolerant CAN, and LIN
Operating Systems
• Windows Vista/XP/2000
• Optional hardware synchronization
• Hi-Speed USB, bus-powered
• 500 V digital isolation
• Bus error logging
• Hardware timestamping – 1 µs resolution
Recommended Software
• LabVIEW
• LabWindows™/CVI
• Visual C++ 6.0
• Visual Basic 6.0
• Borland C/C++
CAN Interfaces
• Philips SJA1000 CAN controller
• Transmit/receive 100 percent bus load
at 1 Mb/s
Application Software
(included)
• CAN/LIN bus monitoring
and logging utility
• ISO 11898 compliance for standard (11-
bit) and extended (29-bit) arbitration IDs
• Software-selectable termination for
low-speed/fault-tolerant CAN
• J1939 compliance
Driver Software
(included)
• NI-CAN
LIN Interfaces
• Atmel ATA6620 transceiver
• LIN 1.3/2.0 and J2602 compliance
• Software-selectable master/
slave termination
Max Transfer
Rate (kb/s)
Hardware
Sync
Software
Termination
Model
Physical Layer
Low-speed/fault-tolerant CAN
Low-speed/fault-tolerant CAN
Transceivers
Ports
API
USB-8472
USB-8472s
USB-8473
USB-8473s
USB-8476
USB-8476s
TJA1054AT
TJA1054AT
TJA1041
TJA1041
ATA6620
ATA6620
1
1
1
1
1
1
125
125
1,000
1,000
20
–
ꢀ
–
Frame
Frame
Frame
Frame
Frame
Frame
ꢀ
ꢀ
–
High-speed CAN
High-speed CAN
–
ꢀ
–
LIN
LIN
ꢀ
ꢀ
20
ꢀ
Table 1. NI USB-847x Selection Guide
With hardware timestamping, you can log messages with
Overview
microsecond-accurate timestamps for reconstructing network events
and correlating data across synchronized devices. All USB-847x
interfaces use an industry-standard 9-pin male D-Sub (DB9) connector
to interface to CAN and LIN buses.
NI USB-847x devices provide Hi-Speed USB interfaces for Controller Area
Network (CAN) and Local Interconnect Network (LIN) monitoring, logging,
and testing. With high-speed CAN, low-speed/fault-tolerant CAN, and
LIN interfaces featuring optional hardware synchronization, you can use
two or more USB-847x devices together to interface to a wide variety of
CAN and LIN networks.
Hi-Speed USB connectivity and onboard frame buffering ensure
no dropped frames, even under 100 percent bus loads.
The USB-847x interfaces are ideal for many types of
applications, including:
CAN Interfaces
USB-847x CAN interfaces feature the industry-standard Philips SJA1000
CAN controller, which implements ISO 11898 CAN functionality. The
SJA1000 offers additional features to aid in system development,
including listen-only mode, sleep/wakeup mode, error counter access,
and self-reception (echo) mode. USB-847x CAN interfaces recognize
standard (11-bit) and extended (29-bit) arbitration IDs and are compatible
with J1939 networks.
• In-vehicle network monitoring and logging
• Bus load monitoring
• Device validation with synchronized data acquisition
• CAN device development and test
• CAN and LIN data correlation with external measurements
The convenient all-in-one design features a captive 2 m USB cable
and built-in transceiver, requiring no extra cables or accessories to
get applications running quickly.
CAN and LIN Interfaces for Hi-Speed USB
features baud rates up to 20 kb/s and offers advanced power
management with a low-power sleep mode.
Hardware Synchronization
No Connection
Optional Ground (V –)
Many automotive applications demand tight integration of CAN, LIN,
analog, and digital measurements. In applications such as CAN device
development and validation, you need to synchronize different measurements
to correlate data. You can program this synchronization in software, but
OS latency and clock drift between the different onboard oscillators
introduce unacceptable delays for certain automotive test applications.
NI offers USB-847x CAN and LIN interfaces with an optional hardware
synchronization feature, with which the USB interfaces can share timing
and triggering signals with other USB-847x interfaces, as well as data
acquisition, vision, and motion devices, to achieve true hardware
synchronization. Determinism is maintained between the trigger signal
and the desired response because timing and triggering signals are
handled in hardware. The host PC software interacts only to retrieve the
data once it is acquired or to write new data.
CAN_L
CAN_H
V –
No Connection
No Connection
V+
Shield
Figure 1. CAN DB9 Connector (USB CAN Modules)
No Connection
Ground
No Connection
LIN
Ground
No Connection
NI-CAN Software
No Connection
VBat
National Instruments provides NI-CAN driver software for Windows
Vista/XP/2000. NI-CAN includes a detailed API and examples for
NI LabVIEW and LabWindows/CVI, Microsoft Visual C/C++ 6.0 and
Visual Basic 6.0, and Borland C/C++. USB-847x interfaces use the NI-CAN
Frame API for frame-level access to messages on CAN and LIN networks.
The NI-CAN driver software also includes the Bus Monitor and NI Spy
utilities to aid in application development.
Shield
Figure 2. LIN DB9 Connector (USB LIN Modules)
Low-speed/fault-tolerant USB-847x CAN interfaces offer software-
selectable termination for compatibility with all low-speed
network configurations.
NI-CAN Frame API
The NI-CAN Frame API offers a powerful interface for accessing NI CAN
hardware. The API enables full access to all traffic on CAN and LIN buses.
It is a powerful tool for implementing a variety of applications, including
CAN and LIN frame-level access, challenge response protocols, remote
frame handling, and advanced synchronization.
Onboard Physical Layer
The CAN physical layer connects the CAN controller to the physical
bus wires. USB-847x CAN interfaces are available with high-speed and
low-speed/fault-tolerant physical layers. All USB-847x devices have
onboard physical layer transceivers and require no external dongles.
The physical layers are internally powered via a DC-to-DC converter
and electrically isolated up to 500 V.
Bus Monitor
To quickly monitor all CAN and LIN bus traffic, use Bus Monitor, a
utility that offers an easy-to-use interface that displays all CAN and
LIN frames on the network, and log the traffic to disk. Bus Monitor
provides options to control, display, and view bus statistics.
LIN Interfaces
NI USB-8476 LIN interfaces, featuring the Atmel ATA6620 LIN
transceiver, are compliant with the LIN 1.3/2.0 and J2602 specifications
and offer software-selectable master/slave termination. The ATA6620
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
CAN and LIN Interfaces for Hi-Speed USB
NI Spy
Specifications
USB Power Requirements
USB-8472(s), USB-8473(s) .................. 250 mA, 5 VDC
USB-8476(s)......................................... 200 mA, 5 VDC
NI Spy is a utility for monitoring NI-CAN API calls made by applications
without recompiling or rebuilding. It is ideal for testing application
functionality, troubleshooting problems, and verifying communication
with CAN devices. NI Spy dynamically captures and displays all NI-CAN
API calls made by applications running on the computer.
Hardware Synchronization
Input clocks ......................................... 1, 10, and 20 MHz
Output clock ........................................ 1 MHz
Trigger lines......................................... 1 input/output
Clock lines........................................... 1 input/output
Examples included for sync to NI-DAQmx, LIN, CAN, and RTSI bus.
Supported Baud Rates
USB-8472(s)......................................... 5,000 to 125,000 baud
USB-8473(s)......................................... 40,000 to 1,000,000 baud
USB-8476(s)......................................... 2,400 to 20,000 baud
Safety
Galvanic CAN channel to
USB isolation.................................. 500 V
Withstand............................................ 2 s maximum
Figure 3. COMBICON Synchronization Connector for USB-847x Devices
Ordering Information
NI USB-8472
1-port, low-speed, USB CAN interface ................................779790-01
Dimensions
Nonsynchronized versions .................. 7.87 by 6.35 by 2.54 cm
(3.1 by 2.5 by 1.0 in.)
Synchronized versions ........................ 7.87 by 7.11 by 2.54 cm
(3.1 by 2.8 by 1.0 in.)
NI USB-8472s
1-port, low-speed, USB CAN interface
with synchronization ............................................................779791-01
Cable length........................................ 2 m
I/O connector ...................................... 9-pin male D-Sub, optional 3-pin
COMBICON for synchronization
NI USB-8473
Operating Environment
1-port, high-speed, USB CAN interface................................779792-01
Ambient temperature.......................... 0 to 55 °C
Relative humidity ................................ 10 to 90%, noncondensing
(tested in accordance with
NI USB-8473s
1-port, high-speed, USB CAN interface
with synchronization ............................................................779793-01
IEC-60068-2-1, IEC-60068-2-2,
IEC-60068-2-56)
NI USB-8476
1-port, USB LIN interface......................................................779794-01
NI USB-8476s
1-port, USB LIN interface with synchronization ..................779795-01
CAN Device Simulator
U.S. 120 VAC ........................................................................779189-01
Euro 240 VAC ........................................................................779189-02
Japan 100 VAC......................................................................779189-07
Cables and Brackets
USB cable strain relief bracket ............................................777550-01
CAN single-termination, high-speed cable, 2 m ..................192017-02
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/can.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
Local Sales and Technical Support
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
SERVICE
NEEDS
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure
using NI products. Visit ni.com/training.
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • 800 813 3693
*351581A-01*
351581A-01
2008-9328-151-101-D
National Instruments • info@ni.com
©2008 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, RTSI, and SCXI are trademarks of
National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and
other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity
independent from NI and has no agency, partnership, or joint-venture relationship with NI.
相关型号:
USB-9201
Portable USB-Based DAQ for Analog SignalsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9211A
Portable USB-Based DAQ for ThermocouplesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9215A
Portable USB-Based DAQ with Simultaneous SamplingWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9221
Portable USB-Based DAQ for High VoltagesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9237
Strain- and Bridge-Based MeasurementsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9421
Portable USB-Based High-Voltage Digital I/OWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9472
Portable USB-Based High-Voltage Digital I/OWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9481
Portable USB-Based High-Voltage Digital I/OWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI
USB-9AB-080-28N-MO1
Interconnection DeviceWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT
USB-9AB-080-28S-MO1
Interconnection DeviceWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT
USB-9AB-130-26S-MO1
Interconnection DeviceWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT
USB-9AB-200-24S-MO1
Interconnection DeviceWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT
©2020 ICPDF网 联系我们和版权申明