USB-8472 [NI]

1-port interfaces for high-speed CAN,low-speed/fault-tolerant CAN, and LIN; 高速CAN ,低速/容错CAN和LIN 1端口接口
USB-8472
型号: USB-8472
厂家: National Instruments    National Instruments
描述:

1-port interfaces for high-speed CAN,low-speed/fault-tolerant CAN, and LIN
高速CAN ,低速/容错CAN和LIN 1端口接口

文件: 总4页 (文件大小:441K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CAN and LIN Interfaces for Hi-Speed USB  
NI USB-8472, NI USB-8472s, NI USB-8473,  
NI USB-8473s, NI USB-8476, NI USB-8476s,  
• 1-port interfaces for high-speed CAN,  
low-speed/fault-tolerant CAN, and LIN  
Operating Systems  
• Windows Vista/XP/2000  
• Optional hardware synchronization  
• Hi-Speed USB, bus-powered  
• 500 V digital isolation  
• Bus error logging  
• Hardware timestamping – 1 µs resolution  
Recommended Software  
• LabVIEW  
• LabWindows/CVI  
• Visual C++ 6.0  
• Visual Basic 6.0  
• Borland C/C++  
CAN Interfaces  
• Philips SJA1000 CAN controller  
Transmit/receive 100 percent bus load  
at 1 Mb/s  
Application Software  
(included)  
• CAN/LIN bus monitoring  
and logging utility  
• ISO 11898 compliance for standard (11-  
bit) and extended (29-bit) arbitration IDs  
• Software-selectable termination for  
low-speed/fault-tolerant CAN  
• J1939 compliance  
Driver Software  
(included)  
• NI-CAN  
LIN Interfaces  
• Atmel ATA6620 transceiver  
• LIN 1.3/2.0 and J2602 compliance  
• Software-selectable master/  
slave termination  
Max Transfer  
Rate (kb/s)  
Hardware  
Sync  
Software  
Termination  
Model  
Physical Layer  
Low-speed/fault-tolerant CAN  
Low-speed/fault-tolerant CAN  
Transceivers  
Ports  
API  
USB-8472  
USB-8472s  
USB-8473  
USB-8473s  
USB-8476  
USB-8476s  
TJA1054AT  
TJA1054AT  
TJA1041  
TJA1041  
ATA6620  
ATA6620  
1
1
1
1
1
1
125  
125  
1,000  
1,000  
20  
Frame  
Frame  
Frame  
Frame  
Frame  
Frame  
High-speed CAN  
High-speed CAN  
LIN  
LIN  
20  
Table 1. NI USB-847x Selection Guide  
With hardware timestamping, you can log messages with  
Overview  
microsecond-accurate timestamps for reconstructing network events  
and correlating data across synchronized devices. All USB-847x  
interfaces use an industry-standard 9-pin male D-Sub (DB9) connector  
to interface to CAN and LIN buses.  
NI USB-847x devices provide Hi-Speed USB interfaces for Controller Area  
Network (CAN) and Local Interconnect Network (LIN) monitoring, logging,  
and testing. With high-speed CAN, low-speed/fault-tolerant CAN, and  
LIN interfaces featuring optional hardware synchronization, you can use  
two or more USB-847x devices together to interface to a wide variety of  
CAN and LIN networks.  
Hi-Speed USB connectivity and onboard frame buffering ensure  
no dropped frames, even under 100 percent bus loads.  
The USB-847x interfaces are ideal for many types of  
applications, including:  
CAN Interfaces  
USB-847x CAN interfaces feature the industry-standard Philips SJA1000  
CAN controller, which implements ISO 11898 CAN functionality. The  
SJA1000 offers additional features to aid in system development,  
including listen-only mode, sleep/wakeup mode, error counter access,  
and self-reception (echo) mode. USB-847x CAN interfaces recognize  
standard (11-bit) and extended (29-bit) arbitration IDs and are compatible  
with J1939 networks.  
• In-vehicle network monitoring and logging  
• Bus load monitoring  
• Device validation with synchronized data acquisition  
• CAN device development and test  
• CAN and LIN data correlation with external measurements  
The convenient all-in-one design features a captive 2 m USB cable  
and built-in transceiver, requiring no extra cables or accessories to  
get applications running quickly.  
CAN and LIN Interfaces for Hi-Speed USB  
features baud rates up to 20 kb/s and offers advanced power  
management with a low-power sleep mode.  
Hardware Synchronization  
No Connection  
Optional Ground (V –)  
Many automotive applications demand tight integration of CAN, LIN,  
analog, and digital measurements. In applications such as CAN device  
development and validation, you need to synchronize different measurements  
to correlate data. You can program this synchronization in software, but  
OS latency and clock drift between the different onboard oscillators  
introduce unacceptable delays for certain automotive test applications.  
NI offers USB-847x CAN and LIN interfaces with an optional hardware  
synchronization feature, with which the USB interfaces can share timing  
and triggering signals with other USB-847x interfaces, as well as data  
acquisition, vision, and motion devices, to achieve true hardware  
synchronization. Determinism is maintained between the trigger signal  
and the desired response because timing and triggering signals are  
handled in hardware. The host PC software interacts only to retrieve the  
data once it is acquired or to write new data.  
CAN_L  
CAN_H  
V –  
No Connection  
No Connection  
V+  
Shield  
Figure 1. CAN DB9 Connector (USB CAN Modules)  
No Connection  
Ground  
No Connection  
LIN  
Ground  
No Connection  
NI-CAN Software  
No Connection  
VBat  
National Instruments provides NI-CAN driver software for Windows  
Vista/XP/2000. NI-CAN includes a detailed API and examples for  
NI LabVIEW and LabWindows/CVI, Microsoft Visual C/C++ 6.0 and  
Visual Basic 6.0, and Borland C/C++. USB-847x interfaces use the NI-CAN  
Frame API for frame-level access to messages on CAN and LIN networks.  
The NI-CAN driver software also includes the Bus Monitor and NI Spy  
utilities to aid in application development.  
Shield  
Figure 2. LIN DB9 Connector (USB LIN Modules)  
Low-speed/fault-tolerant USB-847x CAN interfaces offer software-  
selectable termination for compatibility with all low-speed  
network configurations.  
NI-CAN Frame API  
The NI-CAN Frame API offers a powerful interface for accessing NI CAN  
hardware. The API enables full access to all traffic on CAN and LIN buses.  
It is a powerful tool for implementing a variety of applications, including  
CAN and LIN frame-level access, challenge response protocols, remote  
frame handling, and advanced synchronization.  
Onboard Physical Layer  
The CAN physical layer connects the CAN controller to the physical  
bus wires. USB-847x CAN interfaces are available with high-speed and  
low-speed/fault-tolerant physical layers. All USB-847x devices have  
onboard physical layer transceivers and require no external dongles.  
The physical layers are internally powered via a DC-to-DC converter  
and electrically isolated up to 500 V.  
Bus Monitor  
To quickly monitor all CAN and LIN bus traffic, use Bus Monitor, a  
utility that offers an easy-to-use interface that displays all CAN and  
LIN frames on the network, and log the traffic to disk. Bus Monitor  
provides options to control, display, and view bus statistics.  
LIN Interfaces  
NI USB-8476 LIN interfaces, featuring the Atmel ATA6620 LIN  
transceiver, are compliant with the LIN 1.3/2.0 and J2602 specifications  
and offer software-selectable master/slave termination. The ATA6620  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
2
CAN and LIN Interfaces for Hi-Speed USB  
NI Spy  
Specifications  
USB Power Requirements  
USB-8472(s), USB-8473(s) .................. 250 mA, 5 VDC  
USB-8476(s)......................................... 200 mA, 5 VDC  
NI Spy is a utility for monitoring NI-CAN API calls made by applications  
without recompiling or rebuilding. It is ideal for testing application  
functionality, troubleshooting problems, and verifying communication  
with CAN devices. NI Spy dynamically captures and displays all NI-CAN  
API calls made by applications running on the computer.  
Hardware Synchronization  
Input clocks ......................................... 1, 10, and 20 MHz  
Output clock ........................................ 1 MHz  
Trigger lines......................................... 1 input/output  
Clock lines........................................... 1 input/output  
Examples included for sync to NI-DAQmx, LIN, CAN, and RTSI bus.  
Supported Baud Rates  
USB-8472(s)......................................... 5,000 to 125,000 baud  
USB-8473(s)......................................... 40,000 to 1,000,000 baud  
USB-8476(s)......................................... 2,400 to 20,000 baud  
Safety  
Galvanic CAN channel to  
USB isolation.................................. 500 V  
Withstand............................................ 2 s maximum  
Figure 3. COMBICON Synchronization Connector for USB-847x Devices  
Ordering Information  
NI USB-8472  
1-port, low-speed, USB CAN interface ................................779790-01  
Dimensions  
Nonsynchronized versions .................. 7.87 by 6.35 by 2.54 cm  
(3.1 by 2.5 by 1.0 in.)  
Synchronized versions ........................ 7.87 by 7.11 by 2.54 cm  
(3.1 by 2.8 by 1.0 in.)  
NI USB-8472s  
1-port, low-speed, USB CAN interface  
with synchronization ............................................................779791-01  
Cable length........................................ 2 m  
I/O connector ...................................... 9-pin male D-Sub, optional 3-pin  
COMBICON for synchronization  
NI USB-8473  
Operating Environment  
1-port, high-speed, USB CAN interface................................779792-01  
Ambient temperature.......................... 0 to 55 °C  
Relative humidity ................................ 10 to 90%, noncondensing  
(tested in accordance with  
NI USB-8473s  
1-port, high-speed, USB CAN interface  
with synchronization ............................................................779793-01  
IEC-60068-2-1, IEC-60068-2-2,  
IEC-60068-2-56)  
NI USB-8476  
1-port, USB LIN interface......................................................779794-01  
NI USB-8476s  
1-port, USB LIN interface with synchronization ..................779795-01  
CAN Device Simulator  
U.S. 120 VAC ........................................................................779189-01  
Euro 240 VAC ........................................................................779189-02  
Japan 100 VAC......................................................................779189-07  
Cables and Brackets  
USB cable strain relief bracket ............................................777550-01  
CAN single-termination, high-speed cable, 2 m ..................192017-02  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call 800 813 3693 (U.S.) or go to ni.com/can.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
3
NI Services and Support  
NI has the services and support to meet  
Local Sales and Technical Support  
your needs around the globe and through  
the application life cycle – from planning  
and development through deployment  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
In offices worldwide, our staff is local to the country, giving you access  
to engineers who speak your language. NI delivers industry-leading  
technical support through online knowledge bases, our applications  
engineers, and access to 14,000 measurement and automation  
professionals within NI Developer Exchange forums. Find immediate  
answers to your questions at ni.com/support.  
SERVICE  
NEEDS  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of technical  
support. Visit ni.com/ssp.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our  
products. NI training can shorten your learning curve, save development  
time, and reduce maintenance costs over the application life cycle. We  
schedule instructor-led courses in cities worldwide, or we can hold a  
course at your facility. We also offer a professional certification program  
Hardware Services  
NI Factory Installation Services  
NI Factory Installation Services (FIS) is the fastest and easiest way to  
use your PXI or PXI/SCXI combination systems right out of the box.  
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure  
using NI products. Visit ni.com/training.  
the system to your specifications. NI extends the standard warranty by  
one year on hardware components (controllers, chassis, modules)  
purchased with FIS. To use FIS, simply configure your system online  
with ni.com/pxiadvisor.  
Professional Services  
Our NI Professional Services team is composed of NI applications  
and systems engineers and a worldwide National Instruments Alliance  
Partner program of more than 600 independent consultants and  
integrators. Services range  
Calibration Services  
NI recognizes the need to maintain properly calibrated devices for  
high-accuracy measurements. We provide manual calibration  
procedures, services to recalibrate your products, and automated  
calibration software specifically designed for use by metrology  
laboratories. Visit ni.com/calibration.  
from start-up assistance to  
turnkey system integration.  
Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you  
want to use our products for OEM applications. For information about  
special pricing and services for OEM customers, visit ni.com/oem.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair  
and advance replacement services are also available. We offer  
extended warranties to help you meet project life-cycle requirements.  
Visit ni.com/services.  
ni.com • 800 813 3693  
*351581A-01*  
351581A-01  
2008-9328-151-101-D  
National Instruments • info@ni.com  
©2008 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, RTSI, and SCXI are trademarks of  
National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and  
other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity  
independent from NI and has no agency, partnership, or joint-venture relationship with NI.  

相关型号:

USB-9201

Portable USB-Based DAQ for Analog Signals

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9211A

Portable USB-Based DAQ for Thermocouples

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9215A

Portable USB-Based DAQ with Simultaneous Sampling

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9221

Portable USB-Based DAQ for High Voltages

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9237

Strain- and Bridge-Based Measurements

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9421

Portable USB-Based High-Voltage Digital I/O

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9472

Portable USB-Based High-Voltage Digital I/O

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9481

Portable USB-Based High-Voltage Digital I/O

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9AB-080-28N-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-080-28S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-130-26S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-200-24S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT