Q67000-A9279 [INFINEON]
Smart Low-Side Switch; 智能低边开关![Q67000-A9279](http://pdffile.icpdf.com/pdf1/p00119/img/icpdf/Q67000-A9062_654267_icpdf.jpg)
型号: | Q67000-A9279 |
厂家: | ![]() |
描述: | Smart Low-Side Switch |
文件: | 总8页 (文件大小:205K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
TLE 4224-2/S2
Preliminary data sheet
Smart Low-Side Switch
Features
Product Summary
• Power limitation
• Thermal shutdown
Supply voltage
VS
6.5 - 45
V
V
Ω
A
Drain source voltage VDS(AZ)max 65
• Overload protection
• Short circuit protection
• Diagnostic feedback
• Overvoltage protection
• Reverse polarity protection
• µC compatible input
• Electrostatic discharge (ESD) protection
On resistance
Output current
RON(typ)
ID
0.25
4
P - TO220 -7-1
P - TO220 -7-2
Application
• All kinds of resistive and inductive loads (relays,electromagnetic valves)
• µC compatible power switch for 12 and 24 V applications
• Solenoid control switch in automotive and industrial control systems
General description
Single channel Low-Side Switch in Smart Power Technology (SPT) with µC compatible input and an
open drain DMOS output stage. The TLE 4224-2 is fully protected by embedded protection functions
and designed for automotive and industrial applications.
Block Diagram
VS
VC
VBB
Thermal overload
internal supply
TLE 4224-2
Load
Open Load
Overload
RPD
Semiconductor Group
Page
20.12.96
1
TLE 4224-2/S2
Preliminary data sheet
Maximum Ratings for Tj = – 40°C to 150°C
Parameter
Supply voltage
Symbol
VS
Values
- 15 ... + 60
Unit
V
Supply voltage operational range
Compare voltage
VS
+ 5.5 ... + 45
- 0.3 ... 65
45
V
V
VC
Continuous drain source voltage (OUT)
Input voltage (IN)
VDS
VIN
VST
Tj
V
- 0.3 ... + 6
- 0.3 ... + 32
- 40 ... + 150
- 55 ... + 150
self limited
- 5 ... + 5
100
V
Status output voltage (ST)
Operating temperature range
Storage temperature range
Output current
V
°C
Tstg
ID(lim)
IST
A
mA
mJ
Status output current
Inductive load switch off dissipation energy
Tcase = 125 °C EAS
case = 75 °C
T
200
Thermal resistance
junction - case RthJC
3
K/W
junction - ambient RthJA
65
Pin Definitions and Functions
Pin Configuration
Pin Symbol
Function
1
2
3
4
5
6
7
ST
IN
Status Output (open drain) for error monitoring
Control Input, active high
ENA
GND
VC
Enable Input, active high
Ground, connected internally to cooling lug
Compare voltage for open load detection
Power Output (open drain)
OUT
VS
Supply Voltage
Semiconductor Group
Page
20.12.96
2
TLE 4224-2/S2
Preliminary data sheet
Electrical Characteristics
Parameter and Conditions
Symbol
Values
Unit
VS = 6.5 to 45 V ; Tj = - 40 °C to + 150 °C
(unless otherwise specified)
min
typ
max
1. Power Supply (VS)
Supply current (Output ON)
Supply current (Output OFF)
Operation voltage
IS
5
mA
mA
V
VS ≤ 18 V
IS
1.5
45
VS
5.5
2. Power Outputs
ON state resistance;
ID = 4A
Tj = 25 ° C
RDS(ON)
0.25
Ω
0.5
65
26
40
Tj = 150°C
Z-Diode clamping voltage (OUT)
Pull down resistor
VDS(AZ)
RPD
ton
45
14
10
V
kΩ
µs
Tj = 25 ° C
ID = 0.2 A
ID = 2 A
20
25
50
20
25
40
Output on delay time 1
Output off delay time 1
Output on fall time 1
toff
ID = 0.2 A
ID = 2 A
tfall
1
Output off rise time
trise
t4
1
20
50
60
50
Output off status delay time
ID = 2 A
Output on status delay time 1 2
Overload switch-off delay time 3
t5
150
tDSO
3. Digital Inputs (IN, ENA)
Input low voltage
VINL
- 0.3
2.0
0.2
50
1.0
6.0
0.6
140
22
V
V
Input high voltage
VINH
Input voltage hysteresis
VINHys
V
Input pull down current
Enable pull down current
VS ≥ 9 V; VIN = 5 V IIN
100
15
µA
µA
VS ≥ 9 V; VENA = 5 V IENA
5
4. Digital Status Outputs (ST) open Drain
Output voltage low
IST = 2 mA
VSTL
ISTH
0.5
10
V
Leakage current high
µA
1 See timing diagram, resitive load condition; VS ≥ 9 V
2 Time till status valid after switching on or error detection
3 This parameter will not be tested but assured by design
Semiconductor Group
Page
20.12.96
3
TLE 4224-2/S2
Preliminary data sheet
Electrical Characteristics
Parameter and Conditions
Symbol
Values
Unit
VS = 6.5 to 45 V ; Tj = - 40 °C to + 150 °C
(unless otherwise specified)
min
typ
max
5. Diagnostic Functions
Open load detection voltage VC = 0 V; 8 ≤ VS ≤ 18 V VDS(OL)
0.5*VS
0.6*VS
V
0.45*VS
0.65*VS
(Output OFF)
6.5 ≤ VS ≤ 45 V
Open load compare detection
6.5 ≤ VC ≤ 18 V VDS(OL)C
VC -1.6
100
5.25
4
VC -0.9
500
V
mA
A
Open load detection current (Output ON)
Overload threshold current
VS ≥ 9.5 V
ID(OL)
ID(lim)
Tj = 25°C
A
Tj = 150°C
Overtemperature shutdown threshold 4
Tth
155
185
°C
K
10
Hysteresis
Thys
IVC
VC-Input current
VC ≤ 18 V
0.25
mA
Application Description
This IC is specially designed to drive inductive loads (relays, electromagnetic valves). An integrated
clamp-diode limits the output voltage when inductive loads are discharged.
For the detection of errors there is a open-drain status output, which monitors the following errors by
logic level:
- overloading of output (also shorted load to supply) in active mode
- open and shorted load to ground in active and inactive mode
- thermal overload.
Circuit Description
Input Circuits
The control and enable inputs, all active high, consist of schmitt triggers with hysteresis. All inputs are
connected with pull-down current sources. Not connected inputs are interpreted as LOW.
Switching Stages
The power output consists of a DMOS-power transistor with open drain. The output stage is shorted
load protected troughout the operating range. The integrated clamp-diode limit voltage spikes produ-
ced when inductive loads are discharged.
4 This parameter will not be tested but assured by design
Semiconductor Group
Page
20.12.96
4
TLE 4224-2/S2
Preliminary data sheet
Protective Circuits
An integrated diode protects the device against reverse polarity of the operating voltage.
The load circuit withstands reverse poling within the limits of the maximum ratings (no shorted load
permissible at the same time).
The outputs are protected against current overload and thermal overload.
Error Detection
The status output signals the switching state at normal operating conditions (LOW = off; HIGH = on)
and in case of errors. The outputs are set according to the diagnostic table below.
If current overload occurs, the error condition is stored into an internal register and the output is shut-
down. To reset the register, the control input of the corresponding channel has to be switched off and
then on again.
Open load is detected in on- and off-modus: In on-modus the load current is monitored , in the off-
modus the ouput voltage is monitored.
The open load voltage threshold is programmable via the voltage supplied to the VC.
The state of the error detection circuit is directly dependent on the input status.
Diagnostic Table
Power
Output
Status
Output
Enable
Input
Control
Input
Operating Condition
Normal Operation
ENA
L
IN
L
OUT
OFF
OFF
OFF
ON
ST
L
L
H
L
L
H
H
X
L
H
L
H
H
L
Thermal Overload
OFF
OFF
OFF
OFF
OFF
ON
X
H
L
Open Load or
L
H
H
H
L
shorted load to ground
L
H
L
H
H
L
H
L
Overload or
OFF
OFF
OFF
OFF
L
shorted load to supply
L
H
L
L
H
H
L
H
L
L = LOW
H = HIGH
X = RANDOM
Semiconductor Group
Page
20.12.96
5
TLE 4224-2/S2
Preliminary data sheet
Test Circuit
VD=5V
VS
VC
1000u
470nF
10k
RL
VC
I
s
I
7
5
VC
VS
ST
IN
I
ST
1
2
TLE
4224-2
I
IN
ST
V
ID
6
OUT
V
IN
ENA
I
ENA
VDS
ENA 3
GND
V
4
Application Circuit
VC
C
10k
L
7
VC
ST
VS
1
Status
Output
6
OUT
TLE
4224-2
2
Control
Input
12 V
IN
3
Enable
Input
ENA
GND
4
The blocking capacitor C is recommended to avoid critical negative voltage spikes on VS in
case of battery interruption during OFF-commutating.
Semiconductor Group
Page
20.12.96
6
TLE 4224-2/S2
Preliminary data sheet
Timing Diagram
V
IN
VI NH
VINL
t
t
t
on
off
VDS
V
S
90%
10%
t
t
t
rise
fall
VST
t
t
4
5
t
Overload Current versus temperature
7
6,5
6
5,5
5
4,5
4
3,5
3
-50
-25
0
25
50
75
100
125
150
Junction Temperature [ C ]
Semiconductor Group
Page
20.12.96
7
TLE 4224-2/S2
Preliminary data sheet
Package and ordering code
all dimensions in mm
P - TO220 - 7-1
Ordering code
Q67000-A9062
4.6-0.2
10+0.4
1.27
+0.1
3.75+0.1
1
7
2.6
0.4+0.1
0.6+0.1
1.27
3.9+/-0.3
8.4+/ -0.3
6x1.27=7.62
10.2-0.2
P - TO220 - 7-2
Ordering code
Q67000-A9279
Semiconductor Group
Page
20.12.96
8
相关型号: